• The installation must be performed by a qualified technician according to the

instructions provided with the appliances

.

• Prior to installation, check that the installation's mains voltage corresponds to that indicated

on the rating plate.

1 - INSTALLATION LOCATION

WARNING

• Avoid:

To protect the heat pump from corrosion, avoid installing it in a location where there is a risk
of it being sprayed with seawater or in an aggressive or sulphurous environment (for example,
near a hotspring).

• The equipment room in which certain system components are

installed must be free of gas fumes, flammable gas, high humidity
and high heat.

• Do not store objects near the heat pump so as not to disrupt good

airflow around the exchanger.

CAUTION

• To pre-heat the heat pump, turn on system power at least five (5)

hours prior to operation.

• It is recommended that the power be left on, unless it is not to be

used for an extended period of time.

1.

All cables and their installation must comply with current standards and regulations. For
further details, consult your installer.

2.

All elements must be properly grounded.

3.

The electrical connections must be performed by a qualified technician.

2 - ELECTRICAL POWER SUPPLY INSTRUCTIONS

ALERT SYMBOLS

The following symbols used in this manual, alert you to potentially dangerous conditions
to users, service personnel or the appliance:

This symbol refers to a hazard or unsafe practice which can result in
severe personal injury or death.

This symbol refers to a hazard or unsafe practice which can result in
personal injury or product or property damage.

WARNING

CAUTION

Содержание K60D070ZAA

Страница 1: ...VEC POMPE CHALEUR INVERTER ET CHAUFFAGE LECTRIQUE D APPOINT INT GR HEATING COOLING SYSTEMS WITH INVERTER HEAT PUMP AND BUILT IN SUPPLEMENTARY ELECTRIC HEATING SISTEMA DI RISCALDAMENTO CLIMATIZZAZIONE...

Страница 2: ...id in case of misusage and or from non observance though partial of Manufacturer s installation and or operating instructions Note the heat pump uses R410A refrigerant This product is designed for Res...

Страница 3: ...rflow around the exchanger CAUTION To pre heat the heat pump turn on system power at least five 5 hours prior to operation It is recommended that the power be left on unless it is not to be used for a...

Страница 4: ...m is not designed to be used by people including children whose physical sensory or mental capacities are impaired or who lack experience or knowledge unless they are supervised or have received instr...

Страница 5: ...ilt in control manages the system that supplies the hydraulic system with a water temperature adapted to current needs and according to the operating mode selected on the control unit For installation...

Страница 6: ...be set by a technician during starting up according the installation type 6 1 TEMPERATURES DISPLAY Zone selection with key Z OK 0h 2 4 6 8 10 12 14 16 18 20 22 24 1 2 3 4 5 6 7 0h 2 4 6 8 10 12 14 16...

Страница 7: ...ew Comfort setpoint from 15 C to 25 C ex 21 5 C The setting mode is exited after 5 seconds if no key is pressed 0h 2 4 6 8 10 12 14 16 18 20 22 24 1 2 3 4 5 6 7 Set the knob to The Economy setpoint is...

Страница 8: ...6 5 TIME AND DATE ADJUSTMENT 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 5 6 7 Set the knob to The current day flashes Select the desired day and validate by pressing OK Set the hour using or and validate by...

Страница 9: ...DHW valve control status if the function is activated 6 8 PARAMETERISATION From any knob position simultaneously press and hold keys and for 5 seconds until the screen displays PArA then select User I...

Страница 10: ...ult zone 1 in the case of 2 zones only Water probe fault zone 2 in the case of 2 zones only High water temperature fault Manual reset Outside air probe fault Ambiance probe fault Z1 Ambiance probe fau...

Страница 11: ...to clean them This will damage the internal components and cause an electric shock hazard CAUTION 1 Never use solvents or powerful chemical products Do not wipe plastic parts using very hot water 2 A...

Страница 12: ...heat pump starts but stops rapidly Obstacle in front of the unit s exchanger Clear a space around the unit Insufficient heating or cooling Doors and or windows are open Heat source in cooling mode Se...

Страница 13: ...respect a minimum rest period OFF of 2 to 3 hours when switching from heating mode to cooling mode or from cooling mode to heating mode Ensure that all terminal units if any are in good operating con...

Страница 14: ...F GB I E D P...

Страница 15: ...lettrici ed elettronici Aiutateci a conservare l ambiente in cui viviamo Gli apparecchi contengono spesso dei materiali che se trattati od eliminati in modo non adeguato possono dimostrarsi potenzialm...

Страница 16: ...dificarli senza preaviso En el inter s de mejoras constantes nuestros productos pueden modificarse sin aviso pr vio Unsere Produkte werden laufend verbessert und k nnen ohne Vorank ndigung abge ndert...

Отзывы: