2
2. SPECIFICATIONS
2-1. Unit Specifications
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks: Rating conditions are:
Cooling: Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
Power Surce.......Voltage Rating 400V - 3N - 50Hz .. ....400 V
Control Circuit V 230 V 50 Hz
Cooling
Capacity
kW 5.
1
BTU/h 17
4
00
Air circulation (High)
m
3
/h
760
Moisture removal (High) Liters/h 2.
3
Available voltage range V 342 to 418
Running amperes A 3.
7
Power input W 2
1
00
Power factor % 8
2
C.O.P. W/W 2.
4
Compressor locked rotor amperes A 21.5
Controls / Temperature control
Microprocessor / I.C. thermostat
Control unit
Wireless remote control unit
Timer ON/OFF 24 hours & Daily program, 1-hour OFF
Fan speeds Indoor / Outdoor 3 and Auto / Auto(Hi,LO)
Airflow direction (Indoor)
Horizontal
Manual
Vertical
Auto
Air filter Washable
Compressor
Rotary (Hermetic)
Refrigerant / Amount charged at shipment g R407c/ 1
84
0
Refrigerant control Capillary tube
Noise Power Level
Indoor – Hi / Me / Lo dB-A 55 / 51 / 49
Outdoor – Hi dB-A 64
Refrigerant tubing connections
Flare type
Max. allowable tubing length at shipment m 7.5
Refrigerant tube
Narrow tube
mm (in.)
6.35 (1/4)
diameter
Wide tube
mm (in.)
12.7 (1/2)
Indoor Unit
Outdoor Unit
Unit dimensions
Height
mm
285
630
Width
mm
995
830
Depth mm 206 305
Package dimensions
Height
mm
276
713
Width
mm
1,070
994
Depth
mm
363
413
Weight Net kg 12.0 52
Shipping
kg 15.0 57
Shipping volume
m
3
0.11
0.29
Dimensions & Weight