6. ELECTRICAL DATA
6-1. Electrical Characteristics
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 220 – 240V ~ 50Hz
Rating Conditions Running Amps. A 0.11 /
0.12 0.23
/
0.25 2.7 / 2.6 3.0 / 3.0
Power Input kW 0.023 / 0.027 0.051 / 0.059 0.57 /
0.59 0.64 /
0.68
Full Load Conditions Running Amps. A 0.11 /
0.12 0.23
/
0.25 3.3 / 3.2 3.6 / 3.5
Power Input kW 0.023 / 0.027 0.051 / 0.059 0.72 /
0.74 0.79 /
0.83
Rating Conditions : Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
Indoor Unit MCAV77C5
Outdoor Unit GRV77L5
24
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 220 – 240V ~ 50Hz
Rating Conditions Running Amps. A 0.13 /
0.14 0.29
/
0.30 5.8 / 5.8 6.2 / 6.2
Power Input kW 0.029 / 0.033 0.064 / 0.073 1.23 /
1.26 1.32 /
1.37
Full Load Conditions Running Amps. A 0.13 /
0.14 0.29
/
0.30 7.2 / 7.0 7.6 / 7.4
Power Input kW 0.029 / 0.033 0.064 / 0.073 1.52 /
1.55 1.61 /
1.66
Rating Conditions : Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
Indoor Unit MCAV127C5
Outdoor Unit GRV127L5
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 220 – 240V ~ 50Hz
Rating Conditions Running Amps. A 0.11 /
0.12 0.23
/
0.25 3.9 / 3.6 4.2 / 4.0
Power Input kW 0.025 / 0.029 0.051 / 0.059 0.83 /
0.85 0.91 /
0.94
Full Load Conditions Running Amps. A 0.11 /
0.12 0.23
/
0.25 4.7 / 4.3 5.0 / 4.7
Power Input kW 0.025 / 0.029 0.051 / 0.059 1.01 /
1.02 1.09 /
1.11
Rating Conditions : Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
Indoor Unit MCAV97C5
Outdoor Unit GRV97L5