10
Outdoor Unit GRV127L5
Controller PCB
Part No. POW-CL128E
Control circuit fuse 250 V 3.15 A
Compressor
Type Rotary (Hermetic)
Compressor model C-RN110H5B 80235645
Nominal output W 1,100
Compressor oil ... Amount cc FV68S ... 550
Coil resistance (Ambient temp. 25°C)
Ω
C–R : 1.962
C–S : 5.38
Safety devices Type External(OLR A) External(OLR T)
Overload relay MRA98596-9201 CS-7C115
Operating temp. Open °C 145±5 115±3
Close °C 69±11 95±5
Operating amp.(Ambient temp. 25°C) Trip in 6 to 16 sec. at 21A —
Run capacitor µF 25.0
VAC 400
Crank case heater 240 V 20 W
Fan & Fan Motor
Type Propeller
Q'ty ... Dia. 1 ... ø400
Fan motor model ... Q'ty UE6T-21H5P-S ... 1
No. of poles ... rpm (230 V, High) 6 ... 770
Nominal output W 20
Coil resistance (Ambient temp. 20°C)
Ω
WHT-BRN : 264.5
WHT-VLT : 227.9
VLT-YEL : 22.53
YEL-PNK : 42.37
Safety devices Type Internal fuse
Operating temp. Open °C 145±2
Close °C —
Run capacitor µF 2.0
VAC 440
Heat Exch. Coil
Coil Aluminum plate fin / Copper tube
Rows 1
Fin pitch mm 1.3
Face area m
2
0.379
External Finish Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.