CONTROL SPECIFICATION
When 28
st 31 ,the unit will operate at the set temperature all along.
When the air conditioner is in heat mode and18
st 16 , the unit will operate at the set temperature
all along.
SLEEP mode
Sleep mode 1
When the air conditioner is in cooling and dry mode, the indoor fan runs at low speed After one hour of
operation the set temperature will increase by 1
.One hour later, the set temperature will increase by
1
once more. The unit will then continue operating at 2
above the set temperature.
Normal sleep
When the air conditioner is in heating mode , the indoor fan runs at low speed. After one hour of
operation the set temperature will decrease by 2
. One hour later, the set temperature will decrease
by 2
once more. The unit will then continue operating at 4
below the set temperature.
When the air conditioner is in cooling and dry mode and 23
st 16 ,during the 3 hours after sleep
mode 1 start up ,the set temperature will increase by 1
every hour .The unit will continue operating
at 3
above the set temperature. 8 hours later, the set temperature will decrease 2
.The unit will then
continue operating at this temperature.
When 24
st
27
, during the 2 hours after sleep mode 1 start up, the set temperature will increase
by 1
every hour .The unit will continue operating at 2
above the set temperature.8 hours later, the set
temperature will decrease 2
,the unit will continue operating at this temperature.
When 19
st 25 , during the 2 hours after sleep mode 1 start up, the set temperature will decrease
by 1
every hour. The unit will continue operating at 2 below the set temperature.8 hours later, the
set temperature will increase 2
, the unit will continue operating at this temperature .
When 26
st 31 , during the 3 hours after sleep mode 1 start up, the set temperature will decrease
by 1
every hour. The unit will continue operating at 3 below the set temperature.8 hours later, the
set temperature will increase 2
.The unit will then continue operating at this temperature.
When 19
st 25 , during the 2 hours after sleep mode 2 start up ,the set temperature will decrease
by 1
every hour .The unit will continue operating at 2
below the set temperature.7 hours later, the
set temperature will increase 1
, the unit will continue operating at this temperature .
Sleep mode 2
When 24
st 27 , during the 2 hours after sleep mode 2 start up, the set temperature will increase
by 1
every hour .The unit will continue operating at 2
above the set temperature.7 hours later, the
set temperature will decrease 1
,the unit will continue operating at this temperature .
When the air conditioner is in cooling and dry mode and 23
st 16 , during the 3 hours after sleep
mode 2 start up ,the set temperature will increase by 1
every hour .The unit will continue operating
at 3
above the set temperature.7 hours later, the set temperature will decrease 1
. The unit will
then continue operating at this temperature.
When 28
st 31 ,the unit will operate at the set temperature all along.
When the air conditioner is in heat mode and18
st 16 , the unit will operate at the set temperature
all along.
When 26
st 31 , during the 3 hours after sleep mode 2 start up, the set temperature will decrease
by 1
every hour. The unit will continue operating at 3 below the set temperature. 7 hours later, the
set temperature will increase 1
.The unit will then continue operating at this temperature.
21