CAUTION

Before replacing PCBs, turn off the power and check that all

lamps on the PCB are off before starting work. Electric shock

will occur if work is performed while the lamps are lit.

Electric Shock

Electric Wiring Diagram for 3-room-multi outdoor unit (GRF244MR5IAA)

WHT

YEL

YEL

BLU

BLK

WHT

BLU

BLK 
BLK 
BLK

BLK

BLK

BLK 
BLK

YEL

YEL

WHT

BLK 
BLK 
BLK 
BLK 
BLK

BLK

BLK

BLK 
BLK

YEL

PNK

(RED

)

WHT

BLU

WHT

RED

BLK

WHT

BLK

BLK

WHT

CH

CRANKCASE HEATER

FERRITE CORE

FC1,2

3

1

HEATER

(YEL

)

CN02

CH

WHT

WHT

RE1

RE2

RE1

TH8

THERMISTOR(ROOM C NARROW PIPE)

THERMISTOR(ROOM C WIDE PIPE)

TH9

++

U

GRN

/YEL

WHT

BLU

CM

EARTH

240V

AC220V

1

12

4

UNIT C

INDOOR 

12

4

UNIT B

INDOOR 

4

2
1

GRN

/YEL

BLK

GRN

/YEL

WHT

BLK

GRN

/YEL

GRN/YEL

TERMINAL

BASE

(12P

12

3

2
1
3

2
1
3

2
1

OPERATION CONDENSER

C0

TRANSISTOR

TR

DIODE

BRIDGE DIODE

BD

D

TH7

MVA    MVC

MECHANICAL VALVE

TH6

THERMISTOR(ROOM B NARROW PIPE)

THERMISTOR(ROOM B WIDE PIPE)

RED

CONTROL PCB

VW

UNIT A

INDOOR 

RE2

HIC+

W

W

HIC

-

YEL

GRY

+

+

HIC+

HIC

-

2

2

1

1

(WHT

)

4

4

3

3

CN34

HIC1

HIC1

(WHT

)

6

6

5

57

7

CN01

8

8

9

9

10

10

2

2

1

1

(WHT

)

5

5

4

4

CN30

HIC2

HIC2

(WHT

)

8

8

7

7

10

10

CN02

11

11

(WHT

)

CN18

HIC3

HIC3

(WHT

)

CN03

BLK

1

1

BLK

2

2

FILTER PCB

HS

ORG

79

CN35

(WHT

)

3

1

5

SI

BRN

TERMINAL BASE

(3P

)

6

67

7

WHT

BLK

(WHT

)

PAM

PAM

CN23

4

45

5

WHT

BLK

(WHT

)

1

12

2

BLK

BLK

(WHT

)

CT

CT

(WHT

)

CN08

1

13

3

BLK

BLK

(WHT

)

PRY

PRY

(RED

)

CN21

WW

AC200-L2

CN29

BLK

YEL

YEL

BLK

TH9

TH8

(BLU

)

YEL

YEL

4
3
2
1

CTH

CN20

TH7

TH6

(RED

)

YEL

YEL

4
3
2
1

BTH

CN22

TH5

TH4

TH2

TH1

(BLK

)

DEF

BLU

CN05

BLU

3
1

DEF

WHT

ORG

BLU

BRN

YEL

RED

(BLU

)

6

RED

BLU 
ORG

WHT

YEL

BRN

MVC

MVC

CN39

1

BD

C0

(BLK

)

(

WHT

)(

BLK

)

(WHT

)

(WHT

)

(

WHT

)

(RED

)

3

GRY

+

MC01

MC02

ORG

GRY

6

TH3

1

BLK

WHT

L2
L1

WW

G2

TR

D

HIC PCB

YEL

BLU

BRN

YEL

YEL

RED

WHT

YEL

YEL

+

5
4
3
2
1

CN37

MVA

MVA

6

(BLK

)(

RED

)

BRN

GRN

/YEL

GRN

/YEL

FC1

FC2

GRN

/YEL

W

WHT

RV

6

ORG

RED

4

FMO

MMV

3
2
1

YEL

ATH

CN24

BLU

WHT

MVB

BRN

GRY

BLK

FMOTH

CN16

FMO

CN09

CN06

RV

MMV

CN36

CN13

CN19

COIL

 /GAIKI

COMP

1

3

1

57
3

1

2345

1

3

1

234

1

2

W

G1

GRY

WHT

W

DC280

(WHT

)

3
1

CN01

5

AC200-L1

DC280

-

AC200

W

DC280+

BLK

1

12

2

MVB

CN38

1

2345

5
4
3
2

SOLDERED TERMINAL

TERMINAL

TERMINAL BASE

CONNECTOR

REACTOR

THERMISTOR(ROOM A WIDE PIPE)

THERMISTOR(ROOM A NARROW PIPE)

THERMISTOR(COMPRESSOR TEMP)

THERMISTOR(OUTDOOR TEMP)

THERMISTOR(HEAT EXCHANGER)

W

BOARD-IN-WIRE

HEAT SINK

DEF

MAIN MOTOR OPERATED VALVE

4-WAY VALVE

FAN MOTOR

COMPRESSOR MOTOR

HS

RE1,2

TH5

TH4

TH3

TH2

TH1

DEFROST VALVE

MMV

RV

FMO

CM

DESCRIPTION

SYMBOLS

854

-

2

-

5269

-

184

-

00

-

2

ELECTRIC WIRING DIAGRAM

MULTIPLE INDOOR UNITS

HEAT-PUMP OUTDOOR UNIT FOR THREE-ROOM

Содержание GRF194MR5IAA

Страница 1: ...Required for Installation 2 INSTALLA TION SITE SELECTION 3 2 1 Indoor Unit 2 2 Outdoor Unit 2 3 Outer Dimensions of Outdoor Unit 2 4 Diagram of Outdoor Unit Installation 3 INSTALLATION PROCESS 8 3 1 E...

Страница 2: ...king up and moving the indoor and outdoor units Get a partner to help and bend your knees when lifting to reduce strain on your back Sharp edges or thin aluminum fins on the air conditioner can cut yo...

Страница 3: ...utlet or A C workshop 1 4 Type of Copper Tube and Insulation Material If you wish to purchase these materials separately from a local source you will need 1 Deoxidized annealed copper tube for refrige...

Страница 4: ...stricted air flow around the unit install the unit within the maximum elevation difference H1 H2 H3 above or below the outdoor unit and within a total tubing length L1 L2 L1 L2 L3 from the outdoor uni...

Страница 5: ...n 17 m 6 35 6 35 9 52 Union 12 7 9 52 9 52 A B 94 124 types Outdoor unit Indoor unit 184 type Flare 9 52 Union 12 7 12 7 Flare 9 52 A joint for connecting tubes of different sizes More than 17 m Fig 2...

Страница 6: ...52 C 94 124 types Outdoor unit Indoor unit 94 124 types 184 type Less than 17 m 6 35 6 35 9 52 9 52 9 52 6 35 9 52 A 9 52 B 9 52 C 94 124 type Outdoor unit Indoor unit 94 124 type 94 124 type GRF244MR...

Страница 7: ...will not magnify operating noise or vibration Fasten in place with the anchor bolts M10 provide a base using concrete or similar material and ensure proper drainage select a location where there is n...

Страница 8: ...ure below are spaces that are required in order to maintain performance Install in a location where the dimensions indicated by are ensured and where 2 or more faces of the unit are unobstructed In pr...

Страница 9: ...own and pull it toward you Refer to 2 4 Diagram of Outdoor Unit Installation 3 Remove the tubing panel in order to attach covers as needed according to the number of indoor units Refer to 2 4 Diagram...

Страница 10: ...ngth 3 5 Caution before Connecting Tubes Tightly a Be sure to apply a sealing cap or water proof tape to prevent dust or water from getting into the tubes before they are used b Be sure to apply refri...

Страница 11: ...1 clamp approx every 120 cm Do not wind the armoring tape too tightly since this will decrease the heat insulation effect Also be sure the condensation drain hose splits away from the bundle and drip...

Страница 12: ...is cycle is repeated until the room temperature is lowered to the target level During the heating cycle the direction of refrigerant flow is reversed by a 4 way valve As a result the condenser draws h...

Страница 13: ...th pressure gauges to the service port on the Hi Lo B A C Service valve on narrow tube side Service valve on wide tube side With push pin Hex wrench nominal size 4 mm not provided Manifold gauge speci...

Страница 14: ...in 6 With a hex wrench turn the valve stem on the nar row tube service valve counter clockwise by 90 degrees 1 4 turn for 10 seconds and then turn the stem clockwise to close it again 7 With a standar...

Страница 15: ...le at the outdoor unit This work must be performed during cooling operation The refrigerant gas cannot be recovered during heating operation During winter or if the temperature sensor prevents cooling...

Страница 16: ...nstructions 5 1 General Precautions on Wiring 1 Before wiring confirm the rated voltage of the unit as shown on its nameplate then carry out the wiring closely following the wiring diagram 2 Provide a...

Страница 17: ...ly Single phase AC 220 240 V B CAUTION Be sure to connect the power supply line to the outdoor unit as shown in the wiring diagram The indoor unit draws its power from the outdoor unit 5 3 Wiring Syst...

Страница 18: ...ature sensor Humidity sensor BK BK Black W White R Red GRN Green Y Yellow BL Blue GY Gray Fig 27a INDOOR UNIT BK BK Control panel Terminal board Display receiver panel GRN Fan motor Flap motor W W W W...

Страница 19: ...7 9 CN35 WHT 3 1 5 SI BRN TERMINAL BASE 3P 6 6 7 7 WHT BLK WHT PAM PAM CN23 4 4 5 5 WHT BLK WHT 1 1 2 2 BLK BLK WHT CT CT WHT CN08 1 1 3 3 BLK BLK WHT PRY PRY RED CN21 W W AC200 L2 CN29 BLK YEL YEL BL...

Страница 20: ...PCB HS ORG 7 9 CN35 WHT 3 1 5 SI BRN TERMINAL BASE 3P 6 6 7 7 WHT BLK WHT PAM PAM CN23 4 4 5 5 WHT BLK WHT 1 1 2 2 BLK BLK WHT CT CT WHT CN08 1 1 3 3 BLK BLK WHT PRY PRY RED CN21 W W AC200 L2 CN29 BLK...

Страница 21: ...it on the termi nal plate and fix it securely with the removed ter minal screw using a screwdriver For stranded wiring 1 Cut the wire end with a cutting pliers then strip the insulation to expose the...

Страница 22: ...iring Instructions for the Outdoor Unit The below explanation uses model GRF244MR5IAA as an example With model GRF194MR5IAA there is no terminal block C Be sure to correctly align inter unit cables A...

Страница 23: ...h unit If there is cold air mixed in with the warm air check the tubing connections again Checking tubing and wiring Perform the test run and check that operation is nor mal If there is an error in tu...

Страница 24: ...tubing connections Drain connections are secure and water drains properly Putty has been used to close the hole in the wall All service valves are fully open Remote controller signals are being posit...

Отзывы: