SPAFP
103
11-7. Accessories Supplied with Unit
11-8. Wiring the Receiver Unit
●
Connect the provided wire (already connected to the
receiver unit) to the indoor unit remote controller termi-
nal board.
(The wire has no polarity.)
11-9. Precautions on Simultaneous Installation of
Wired Remote Controller and Wireless Remote
Controller
By installing a wired remote controller, the wireless receiv-
er unit can permit dual remote control operation at the
same time.
(Up to 2 units of remote controllers – a wireless remote
controller and a wired remote controller – can be installed.)
Dual remote control operation can control 1 or multiple air
conditioners using several remote controllers.
CN001
2PWHT
WHT
BLK
Indoor unit
Receiver unit
Remote
controller
terminal
board
CAUTION
●
Be sure to determine the correct terminal
numbers on the indoor unit when wiring
the remote controller. The remote con-
troller will be damaged if high voltage
(such as 220 – 240 VAC) is applied.
●
The wireless receiver unit components
cannot be used for more than 1 indoor
unit at a time. (However, separate receiv-
er units may be used simultaneously.)
●
When a wireless receiver unit and a wired
remote controller are used simultaneous-
ly, assign either the wireless remote con-
troller or the wired remote controller as
the sub remote controller unit.
●
Connection diagram
1
1
1
2
2
Receiver unit
AAA alkaline battery
Remote control
holder
Tapping screw
4
×
16
4
5
No.
Q'ty
No.
Parts
Q'ty
1
2
3
Remote control
unit
t
(1) To assign the wired remote controller as the sub
unit, locate the address connector at the rear of the
wired remote controller PCB and disconnect it.
Reconnect it to the sub unit position.
(2) To assign the wireless remote controller as the sub
unit, locate the DIP switch [S003] on the wireless
control unit. Set the No. 3 switch to the ON position.
04-393 DC INV Tech p 64-110 12/13/04 11:35 AM Page 103