background image

2. DIMENSIONAL DATA

CA9FIB0R5IAA

Unit: mm

REFRIGERANT TUBING JOINT
WIDE TUBE: o.d. 12,7 (1/2")

7

Содержание 38.7106.021

Страница 1: ...TECHNICAL DATA SERVICE MANUAL INDOOR UNIT CA9FIB0R5IAA 0 8180 604 01 10 2012 CA9FIB0R5IAA 38 7106 021 SPLIT SYSTEM AIR CONDITIONER Model No Product Code No...

Страница 2: ...w wiring to touch the refrigerant tubing compressor or any moving parts of the fan Do not use multi core cable when wiring the power supply and control lines Use separate cables for each type of line...

Страница 3: ...eds off function 16 4 17 Capacity Test Mode 16 4 18 Diagnostic 17 4 19 Indoor unit jumpers Configuration 18 4 20 Outdoor unit jumpers Configuration 18 5 INDOOR UNIT AND REMOTE CONTROL ADDRESS 19 5 1 A...

Страница 4: ...nsions Unit Height mm Width mm Depth mm Ceiling panel Height mm Width mm Depth mm Package dimensions Unit Height mm Width mm Depth mm Volume m3 Ceiling panel Height mm Width mm Depth mm Volume m3 Weig...

Страница 5: ...es Type Operating temp Open C Close Run capacitor F VAC Flap Motor Type Model Rating Coil resistance Ambient temp 25 C Heat Exch Coil Coil Rows Fin pitch mm face area m2 DATA SUBJECT TO CHANGE WITHOUT...

Страница 6: ...oil sensor Resistance k Thermistor Room sensor Resistance k Drain pump Model Rating Voltage Input Total head capacity Safety float switch Model Contact rating 120 C NTC THERMISTOR 10 at 25 C 10 at 25...

Страница 7: ...2 DIMENSIONAL DATA CA9FIB0R5IAA Unit mm REFRIGERANT TUBING JOINT WIDE TUBE o d 12 7 1 2 7...

Страница 8: ...3 ELECTRICAL DATA 3 1 Electric Wiring Diagrams 8...

Страница 9: ...s but in any case The minimum time interval between an OFF and a ON operation is not lower than 3 minutes The minimum operating time is not lower than 3 minutes The maximum acceleration deceleration r...

Страница 10: ...The minimum off time of compressor is 3 minutes The indoor fan can change speed only after it has operated at the same speed for 30 sec if in AUTO and 1 sec for the other settings High Med Low 4 3 He...

Страница 11: ...two modes is according to the above graph and following table If 3 C Dt 1 C and the compressor is off for more than 1 hour If Dt 3 C and compressor is off for more than 3 minutes If 1 C Dt 3 C and the...

Страница 12: ...1 C LEVEL 2 FMO switches 9 minutes off and 3 minutes ON 15 C FMI switches between L and LL every 30 seconds RV off CM off 15 C DRY OFF ZONE FMO off FMI off RV off SPT Set Point Temperature 4 6 Fan Mo...

Страница 13: ...coil temperature ICT decreases and acts by decreasing the compresor speed The system exit this protection routine when ICT temperature rises above 5 C 4 9 2 Cold draft This feature prevents the supply...

Страница 14: ...built in thermistor is always monitored by the control system and kept operating in a safe area If temperature exceeds 100 C operation is automatically stopped 4 10 4 Outdoor fan power module overhea...

Страница 15: ...mote controller icon I FEEL shown on the display This feature provides a personalised environment since the temperature can be detected where the remote controller is located It is possible to de acti...

Страница 16: ...for more than 5 seconds the IFEEL and FAN buttons on the remote controller With this option active the OPERATION TIMER and STANDBY lamps are switched off even during operation they activates only in c...

Страница 17: ...more than one trouble present is always showed at first the one with the highest priority 1 2 3 etc Sensor damaged means a situation where sensor is short circuited or opened In case of damaged senso...

Страница 18: ...is shipped with jumpers set according to the following table JUMPER STATUS JP1 open JP2 open 4 20 Outdoor Unit Jumpers Configuration Unit is shipped with jumpers set according to the following table J...

Страница 19: ...emote control unit directly at the air conditioner receiver System starts and runs for 3 minutes After 3 minutes operation in case the setting is right the unit switches to COOL mode and stops set poi...

Страница 20: ...er is being supplied WARNING If the following troubleshooting must be done with power supplied be careful not to touch any uninsulated live part that can cause electric shock 6 2 CIRCUIT BREAKER TRIPS...

Страница 21: ...e YES Is the unit in protection mode see par 4 9 e 4 10 Wait some minutes to restore normal condition YES NO CASE 1 CASE 2 There is a fault signaling Check outdoor unit leds signaling see par 4 18 Nor...

Страница 22: ...he sensor COMMUNICATION ERROR Is the communication fuse blown Replace fuse 100mA The fuse may be not fitted rightly in the fuseholder Check for right connection of communication wires Check outdoor un...

Страница 23: ...6 4 OUTDOOR UNIT DOES NOT RUN AND NO FAULT IS DISPLAYED 6 5 ONLY OUTDOOR UNIT IS OFF 23...

Страница 24: ...he fuse may be not fitted rightly in the fuseholder Check for right connection of communication wires Turn off power supply and after 3 minutes turn on again NO See section 6 3 FAULT ON THE INDOOR UNI...

Страница 25: ...air filters Check the air filters Are they clogged YES NO Check the expansion valve coil Is it rightly connected and the resistance value correct Replace the expansion valve coil NO There is the possi...

Страница 26: ...ES ARE OBSERVED 2 OPERATION DOES NOT SWITCH FROM HEAT TO COOL AND FROM COOL TO HEAT Remote controller unit may be defective Receiver assy may be defective Check the connection of reversing valve coil...

Страница 27: ...6 8 NOISE PROBLEM 27...

Страница 28: ...isired electric part from terminal plate PCB assy capacitor etc Similary disconnect the connector Then measure the insulation resistance fig 1 to 4 Refer to electric wiring diagram NOTE If the probe c...

Страница 29: ...0 8180 604 01 10 2012 R D 28 Reyrieux BP 131 01601 Tr voux CEDEX France T l 04 74 00 92 92 Fax 04 74 00 42 00 R C S Bourg en Bresse B 759 200 728...

Отзывы: