6) TROUBLESHOOTING
6-1 CHECK BEFORE AND AFTER «TROUBLESHOOTING»
(A)
Check power supply wiring.
• Check the power supply wires are correctly connected.
(B)
Check power supply.
• Check that voltage is in specified range (±10% of the rating).
• Check that power is being supplied.
• WARNING: If the following troubleshooting must be done with power supplied,
be careful not to touch any uninsulated live part that can cause electric shock
6-2 CIRCUIT BREAKER TRIPS OR FUSE BLOWS.
• When circuit breaker is set to ON, it trips in a few moments. Resetting is not possible.
• Measure insulation resistance. There is a possibility of ground fault.
If resistance value is 1 Mohm or less, insulation is defective.
20
Содержание 38.7106.021
Страница 7: ...2 DIMENSIONAL DATA CA9FIB0R5IAA Unit mm REFRIGERANT TUBING JOINT WIDE TUBE o d 12 7 1 2 7...
Страница 8: ...3 ELECTRICAL DATA 3 1 Electric Wiring Diagrams 8...
Страница 23: ...6 4 OUTDOOR UNIT DOES NOT RUN AND NO FAULT IS DISPLAYED 6 5 ONLY OUTDOOR UNIT IS OFF 23...
Страница 27: ...6 8 NOISE PROBLEM 27...