13
Heat exchanger
Narrow tube
O.D.
6.35mm
(1/4")
Wide tube
O.D.
9.52mm
(3/8")
Muffler
Accumulator
Compressor A
Capillary
tube
( )
Check valve
Strainer
Heat exchanger
Narrow tube
O.D.
6.35mm
(1/4")
Wide tube
O.D.
9.52mm
(3/8")
Muffler
Accumulator
Compressor B
( )
Check valve
Strainer
Heat exchanger
Check
port
Check
port
Indoor Unit A
Indoor Unit B
Wide Tube Service valve
Narrow Tube Service valve
Capillary tube
Drier
Drier
4 – Way
valve
4 – Way
valve
Insulation of Refrigerant Tubing
To prevent heat loss and wet floors due to dripping of
condensation water, both the wide and narrow tubes
must be well insulated with proper insulation
material. The thickness of the insulation should be a min.
8 mm.
After a tube has been insulated,
never try to bend it into a narrow
curve because it can cause the
tube to break or crack.
IMPORTANT
CAUTION
Wide tube
Thickness:
Min. 8 mm
Insulation
Narrow tube
Thickness:
Min. 8 mm
Heating cycle