SETUP
1. Open the shipping carton and carefully remove the unit from the shipping carton.
2. Set the snow machine on a flat dry surface. Locate the included bracket from the package
and install it using the supplied hard ware to the side casing.
3. Remove the fluid tank cap and fill the tank with TECHNI-LUX branded snow fluid only and
then tighten the cap.
4. Firmly attach the timer remote control unit to the rear remote control socket on the unit.
5. Set the AIR VOLUME switch, to produce either a large snow output or small snow output. Put
the switch in the top position for large flakes or the bottom position for small flakes.
7. Plug the unit in to a matching power supply.
8. Follow the operating instructions on the next page for proper operation.
PRODUCT VIEW
5
Fluid Tank Cap
Output
Remote Input
DMX In
DMX Out
Air Volume
Power switch
Fuse holder
Power Input
Dip switch
Mounting
Always consult a qualified professional when rigging. Consider access for routine maintenance
and refilling the fluid container, when selecting a mounting position. This unit must be mounted
in a horizontal position with only a +/- angle of about 20 degrees, to avoid any spillage of fluid
from the container. The position selected must provide adequate room for ventilation and
projection of the snow effect. Mount the fixture securely using a mounting clamp and a safety
cable. Always keep cords out of the way, thus preventing any trip hazards. Secure all cables
properly and keep them away from any fluids. Do not mount where the fixture will be exposed
to rain, high humidity, extreme temperature changes or restricted ventilation. Do not obstruct
any vents, as this will prevent the machine from producing the snow effect and cause the blower
to malfunction.
This unit requires the mains voltage and frequency to be 120vAC 50/60Hz. The listed power
rating is its average wattage under normal conditions. All units must be powered directly from a
Power
Do not apply power to the unit until power source is verified. For protection
against electric shock, fixture must be connected to suitable earth ground. Make
sure fixture is disconnected from power mains before any service.