Maintenance 

 

Make sure fixture is cool and disconnected from power mains before any service. 

 

 

 
Weekly operating hours and environmental conditions will establish how often the fixtures need 
cleaning.  Fixtures should be cleaned and inspected at least once a month to maintain optimum 
performance.    Accumulation  of  dust  and  fog  residue  increases  heat  build  up,  can  lead  to 
malfunctions, overheating and reduction in maximum light output, reduced fixture life and over 
all performance.  Before conducting any maintenance, disconnect fixture from power mains.   
  

1) Disconnect fixture from power mains. 
2)  Use  a  vacuum  with  a  soft  brush  to  remove  dust  collected  on  external  vents  and  internal 

components.    If  using  an  air  compressor,  use  low  pressures  and  extreme  care  to 
prevent damaging any internal parts or effects. 

4) Clean all optical elements when the fixture is cold.  Use a soft lint free cotton cloth or tissue 

and cleaner safe for plastics.  

5) Inspect clamps and safety cables to ensure fixture is secure and safe. 

 
 
 
 

Troubleshooting 

Diagnostic  technique  for  DMX  issues:  Set  suspect  fixture’s  Start  Address  the  same  as  a  correctly 
functioning fixture. If both units then function correctly, issue is programming. 

 
 

Symptom 

Possible Cause / Solution 

No Power 

Check for power on mains 
Check power cord inserted correctly 

Erratic / No response to DMX 

Check data cables: connection and proper wiring 
Check Display, fixture in DMX512 Mode 
Verify Start Address of Fixture 

Incorrectly responds to DMX 
 

Check for overlapping addresses 
Check Fixture Channel Mode 
Check Menu settings 
Cycle Power and Retest 

No Output or Image Partially Obstructed 

Check Framing Shutter positions and Gobo 

Image is Backwards 

Check Gobo Orientation in GOBO Holder 

 
 
 
 
 
 
 

Содержание mzSCULPT TH-SCLPMZ100QA/B

Страница 1: ...mzSCULPT 100 LED Zoom Profile LED Ellipsoidal Information specifically for TH SCLPMZ100WW B TH SCLPMZ100QA B V1 0 This manual contains important information Please read before operating fixture...

Страница 2: ...shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or Techni...

Страница 3: ...s 8 Fixture Menu 9 Menu WW Warm White 9 Menu QA Red Blue Green Amber 10 DMX Channel Assignments and Values 10 WW 1 CHANNEL MODE 10 WW 2 CHANNEL MODE 10 QA 5 CHANNEL MODE 11 QA 9 CHANNEL MODE 11 DMX 51...

Страница 4: ...40 C Min distance to flammable surface 3 3 ft 1 0 m Min distance to illuminated surface 1 0 ft 0 3 m Electrical Voltage 100 240VAC 50 60Hz Auto Ranging Rated Power 100W Connection NEMA 5 15 3 Pin Edi...

Страница 5: ...shipping charges to return products received in non original packing and or cartons Purpose of Manual The purpose of this manual is to explain the necessary steps for using this fixture properly and...

Страница 6: ...ting positon on the bracket is provided to alter the mounting height Secure all cables properly and keep away from hot surfaces to prevent heat damage and trip hazards Do not obstruct any vents 1 Colo...

Страница 7: ...king Knobs enough to allow Lens Barrel rotation 2 To Rotate a Choose the orientation best suited to the application b Retighten the Lens Barrel Locking Knobs 3 To Remove a Rotate Lens Barrel to hard s...

Страница 8: ...of 23 9mm Basic Setup Wiring Diagrams There are two basic ways to use the fixture One is in standalone which does not require the use of any data lines to be connected nor any controller each fixture...

Страница 9: ...to change VALUE if present ENTER to Confirm and Save Menu WW Warm White Press ENTER to confirm and save change OPTION VALUE DESCRIPTION dxxx 0 512 DMX Start Address xxx 1CH 1 Channel Mode 2CH 2 Channe...

Страница 10: ...Mixed S AA Auto AC and AF Run Mixed Sound Trigger Rxxx 0 255 Red Manual Dimmer gxxx 0 255 Green Manual Dimmer bxxx 0 255 Blue Manual Dimmer axxx 0 255 Amber Manual Dimmer Uxx Firmware Version xx dI x...

Страница 11: ...L MODE Channel Function Values 1 Red 0 255 Dimmer 0 100 2 Green 0 255 Dimmer 0 100 3 Blue 0 255 Dimmer 0 100 4 Amber 0 255 Dimmer 0 100 5 Dimmer Curve Speed 0 009 None 10 50 Linear 51 101 Square 102 1...

Страница 12: ...ress In this case the fixtures will be slaved together and respond to the same data Because all fixtures see the same data fixtures may be set to any address without concern for the order they are con...

Страница 13: ...sses Example Select Start Addresses for 4 fixtures each requiring 3 channels of DMX For this example start with the first unit set to the first possible Start Address 1 This fixture occupies 3 DMX cha...

Страница 14: ...revent damaging any internal parts or effects 4 Clean all optical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safet...

Страница 15: ...rent to the user and is handled by the controller The physical signals are transmitted using a twisted pair of wires and a common shield a configuration called Balanced The controller and all receivin...

Страница 16: ...able 30 black w spring snap clip CA XLR5 5 Pre made 5 5 pin XLR Cable CA XLR5 10 Pre made 10 5 pin XLR Cable CA XLR5 15 Pre made 15 5 pin XLR Cable CA XLR5 25 Pre made 25 5 pin XLR Cable CO XLRTERM3 X...

Отзывы: