background image

pict. 4/a

pict. 4

CONNECTION TO THE DMX SIGNAL

The connection of the DMX signal to the XS must be made by using the signal input XLR 5 pin or XLR3  pin connectors which are 
located on the rear panel of the XS. (pict.4)

The pin nomenclature of the connectors for the connection to the DMX signal is listed in the table. (pict.4/a)

In order to avoid any problem in the signal transmission, it is warmly suggested to use a cable for high speed data transmission. 

The usage of a normal microphonic or audio cable is suggested only for lines max 100 mts long. The best performances are with 
 microphonic cable of mm2x0.25 + ground or with cable for data transmission. If the lines have a total length over 150-200 mts it is 
suggested to use our DMX Repeater Amplifier.

DMX OUT 

DMX IN

PIN

WIRE

SIGNAL

1

SHIELD

GROUND/RETURN/OV

2

INNER CONDUCTOR

DATA COMPLEMENT (-, INVERTED)

3

INNER CONDUCTOR

DATA TRUE (+, NON INVERTED)

4

N.C.

5

N.C.

DMX TERMINAL LINE

The wrong connection of the terminal line or its  non-connection are probably the most frequent reasons for the defective functioning  
of the DMX line. The terminator is a resistor fitted between the two “data” lines (pins 2 and 3 of an XLR 5 or XLR 3 pin connector) 
at the end of the cable furthest from the transmitter. The terminator resistor should have the same value as the impedance of the 
connection cable.
We supply a terminal with a 100 Ohm resistor.
It is recommanded that all DMX 512 systems have the termination resistor at the and of the line.

WARNING

!

... 7 ...

Содержание HMI 1200W/S XS

Страница 1: ...ing page 6 DMX signal connection page 7 Control panel and configuration XS1200 page 8 Menu tree options XS1200 page 10 Menu tree options XS700 B page 12 Use in DMX 512 8 16 bit XS1200 page 13 Use in D...

Страница 2: ...meter from walls or any other type of flammable surfaces 3 Maintain minimum distance to lighted objects of 1 0 meter 4 Replace fuses only with the specified type and rating 5 Do not install the spot...

Страница 3: ...tinuous positioning FROST 2 frost filters 1 continuous frost SETTING Built in microprocessor with LED display and graphic LCD DISPLAY graphic LCD with flip function can be rotate through 180 INPUT SIG...

Страница 4: ...D ELECTRONIC ZOOM continuous positioning 17 27 MOTORIZED ELECTRONIC FOCUS 1m IRIS continuous positioning ROTATING PRISM FROST 1 fixed medium frost SETTING Built in microprocessor with LED display DISP...

Страница 5: ...ing requirement lock the head in vertical or horizontal position 4 For spot installation to a truss check carefully that the security ring is well fixed with a chain to both truss and unit 5 On the me...

Страница 6: ...balance has been obtained Tc 85 C 5 The protection screens the lenses or the ultraviolet filters must be replaced if they are visibly damaged and their effectiveness has been reduced for example by c...

Страница 7: ...ulb with fingers If this happens clean the bulb before use with cloth and alcohol Polish with a dry cloth 5 Taking care that the protuberance of the bulb is not set towars the mirror reflector and the...

Страница 8: ...nsmission If the lines have a total length over 150 200 mts it is suggested to use our DMX Repeater Amplifier DMX OUT DMX IN PIN WIRE SIGNAL 1 SHIELD GROUND RETURN OV 2 INNER CONDUCTOR DATA COMPLEMENT...

Страница 9: ...tion of the fixture calibration of the wheels BALLAST parameters of the lamp strikes control To select any of the given options press any key The dynamic keys have the OK ESC Up and Down options Press...

Страница 10: ...ssible to set no normal normal pan PI pan inversion To go back to the options without making any change press the MENU button DMX SPEC to activate deactivate the reset of the fixture the control of th...

Страница 11: ...DIMM SHUTT Dimmer MOD1 MOD2 Shutter MOD1 MOD2 Rotation MOD1 MOD2 Advanced Shutter COL Y N Shutter GOBO Y N Time Out Y N Time Time DMX 3 Sec HRS COUNT Hours Counter Lamp 0 Fixture 0 DISPLAY Flip Y N A...

Страница 12: ...pd V I Lampd A V PFC V Power W Tent Nr Lamp xxxx Advanced Strikes Strikes Count Strikes Lamp Type NOTE All the available lamp are HMI 1200 S DE Osram HTI 700 DE Osram MSI 700 DE Philips HMP 575 DE boo...

Страница 13: ...Tilt Resolution 8 16 Bit Ramp Fast Slow Ramp select Effs Effects SH C Off On Shutter on color change SH G Off On Shutter on gobo change Dmmd Mod1 Mod2 Dimmer 0 255 Closed Open Open Closed Shmd Mod1 Mo...

Страница 14: ...DMX Next Ch Channels Use the Up and Down keys up to when the cor rect Address is shown on the display Once you have set the required number store it by pressing the OK button To exit from the selected...

Страница 15: ...nd the sub menu will appear Chan DMX Next Ch Channels Use the Up and Down keys up to when the cor rect Address is shown on the display Once you have set the required number store it by pressing the OK...

Страница 16: ...0 71 76 83 89 95 3 GOBO A GOBO WHEEL Full Beam Gobo 1 Gobo 2 Gobo 3 Gobo 4 Gobo 5 0 44 45 89 90 134 135 179 180 224 225 255 0 17 18 34 35 52 53 70 71 87 88 100 4 STROBE SHUTTER STROBE Full beam Contin...

Страница 17: ...26 227 237 238 248 249 255 0 58 59 62 63 67 68 71 72 75 76 80 81 84 85 88 89 92 94 97 98 100 15 GOBO A POS ROT POSITION ROTATING Position indexed Rainbow slow clockwise Rainbow mid1 Rainbow mid2 Rainb...

Страница 18: ...ot prism 2 mid 1 Rot prism 2 mid 2 Rot prism 2 fast 0 7 8 12 13 25 26 38 39 51 52 64 65 77 78 90 91 103 104 116 117 127 128 140 141 153 154 166 167 179 180 192 193 205 206 218 219 231 232 244 245 255...

Страница 19: ...0 71 76 83 89 95 3 GOBO A GOBO WHEEL Full Beam Gobo 1 Gobo 2 Gobo 3 Gobo 4 Gobo 5 0 44 45 89 90 134 135 179 180 224 225 255 0 17 18 34 35 52 53 70 71 87 88 100 4 STROBE SHUTTER STROBE Full beam Contin...

Страница 20: ...w slow anti clockvise Rainbow mid1 Rainbow mid2 Rainbow mid3 Rainbow fast 0 149 150 160 161 171 172 182 183 193 194 204 205 216 216 226 227 237 238 248 249 255 0 58 59 62 63 67 68 71 72 75 76 80 81 84...

Страница 21: ...n the back of the cover are clean Prior to operate inside the fixture a Disconnect power before head cover opening or servicing b Don t open the head cover before five minutes after the switching off...

Страница 22: ...P40 PAN PLATE SP41 NUT SP42 LOWER PAN BUSH SP43 SPACER SP44 PULLEY SP45 MOTOR SP46 ENCODER SUPPORT SP47 ENCODER 250 P C SP48 ENCODER 50 1 SP49 PAN FLYWHEEL SP60 BRACKET SP61A LATERAL BRACKET SP61 LATE...

Страница 23: ...SPIRAL SPRING SP240 FLYWHEEL SP241 SPACER SP242 MOTOR SP244 MOTOR SP245 GOBO PANEL SP246 HUB SP247 SHAPED RESET GOBO SP249 MOTOR SP251 P C SENSOR DOWN SP253 P C SENSOR UP SP254 MOTOR SP255 IRIS HUB SP...

Страница 24: ...63 64 76 75 75 74 65 61 a 7 68 69 8 85 1 37 2 3 36 110 105 115 111 114 116 113 96 87 90 88 93 119 117 109 61 112 112 a 108 106 121 122 118 120 9 49 48 44 45 46 47 43 35 38 32 42 39 13 31 40 41 24 27...

Страница 25: ...6 264 240 238 225 226 227 228 230 141 150 237 246 238 231 232 232 231 240 233 232 235 234 236 237 a 237 b 249 245 241x4 239 275 253 242 244 237 254 251 247 259 262 261 263 260 270 255 256 265 266 269...

Страница 26: ...25 TD XS700 B base PROVISIONAL...

Страница 27: ...26 TD XS700 B head PROVISIONAL...

Страница 28: ......

Отзывы: