background image

 

Unpacking 

Immediately upon receipt, carefully unpack and inspect the  fixture to verify that all parts are 
present and have been received in good condition.  If any parts appear damaged from shipping 
or the shipping carton shows signs of mishandling,  notify the shipper immediately.  Retain 
carton and  all  packing material for inspection.  In the event that  the  merchandise  is to be 
returned, the original carton and packing must be used.  The customer will be billed for a new 
carton and packing if merchandise is received without the original carton and packing. 
 

Claims 

Physical damage must be reported to the  Freight Carrier or Shipping Company upon 
receipt of merchandise.  Damage incurred in shipping is the responsibility of the Freight 
Carrier or Shipping Company.  It is the customer’s  obligation in the event that 
merchandise is  received  damaged,  to notify the  Freight Carrier or Shipping Company 
immediately.  All other claims  not related to damage  incurred during shipping must be 
made to the Dealer or Distributor within 7 days of receiving merchandise.  

 

Returns 

Returned merchandise must be  in the original packing  with  a Return Merchandise 
Authorization number (RMA) clearly listed on the shipping label.    Items sent by Freight 
Collect or without a RMA number will be refused.   Call your sales person and request a 
RMA prior to shipping.  Be prepared to provide the model number, serial number and 
description of the nature of the return.  Shipping damage resulting from inadequate 
packaging is the customer’s responsibility.  Customer will be charged additional shipping 
charges to return products received in non original packing and or cartons. 

 
 

Power 

 

Do not apply power to the fixture until power source is verified. 

 

For protection against electric shock, fixture must be connected to suitable earth ground. 
Make sure fixture is disconnected from power mains before any service. 

 
This fixture automatically adjusts to mains voltage and frequency 100-240vac 50/60Hz.  The 
listed power rating is its average wattage under normal conditions. All fixtures must be powered 
directly from a switched circuit.  This fixture cannot be run on a rheostat or dimmer circuit even 
if used solely for a 0% to 100% switching.  Before applying power to a fixture, check that the 
fixture’s input voltage matches the power source voltage.  Consult a qualified electrician if there 
are any concerns about proper connection to power. 
 
 

Mounting 

Always consult a qualified professional when rigging.  Consider access for routine maintenance 
when selecting a mounting position. This fixture may be mounted in any position provided there 
is adequate room for movement and ventilation.  Mount the fixture securely using a mounting 
clamp and a safety cable.  This fixture features dual yokes making it useful for floor standing at 
different angles. Always keep cords out of the way, thus preventing any trip hazards. Secure all 
cables properly. Do not mount where the fixture will be exposed to rain, high humidity, extreme 
temperature changes or restricted ventilation.  Do not obstruct any vents. 

Содержание DL-PAR64C183/B

Страница 1: ...Information specifically for DL PAR64C183 B Black DL PAR64C183 P Polished V1 This manual contains important information Please read before operating fixture ...

Страница 2: ...hall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or Techni Lux directly to obtain an RMA The RMA number must be clearly listed on the shipping label Due care must be exercised in packing all merchandise to be returned All repairs must be accompanied by a writ...

Страница 3: ...d 7 Mode 3 Color Fade 7 Mode 4 Sound Active 7 Mode 5 Slave 7 Mode 6 DMX 7 DMX 512 Control 8 DMX Data Connection 8 Data Terminator 8 Adapter 5 to 3 pin 8 DMX Start Address 9 DMX Channel Assignment 9 CH 1 Master Dimmer 9 CH 2 Red 9 CH 3 Green 10 CH 4 Blue 10 CH 5 Color Macro Scroll 10 CH 6 Shutter 11 Maintenance 12 Accessory Items sold separately 12 Troubleshooting 13 DMX 512 Background 13 ...

Страница 4: ...isplay menu for settings Dual yoke for floor or hang mounting Clamp mounting hole Physical Color Black or Polished Size 13 x 11 25 x 10 6 Weight 5 1 lbs 2 3 kg Housing Material Aluminum Environmental Location Indoor Max ambient temperature 105 F 40 C Min distance to flammable surface 3 3ft 1m Min distance to illuminated surface 1ft 0 3m Electrical Voltage 110 240vAC 50 60Hz Rated Power 30W Fuses 0...

Страница 5: ...of the return Shipping damage resulting from inadequate packaging is the customer s responsibility Customer will be charged additional shipping charges to return products received in non original packing and or cartons Power Do not apply power to the fixture until power source is verified For protection against electric shock fixture must be connected to suitable earth ground Make sure fixture is ...

Страница 6: ...different modes that are available on this fixture via the LED display Each mode is selectable from the display menu located at the back of the fixture Modes 1 to 5 refer to the stand alone operations that are available Modes 1 4 do not require any data line to be connected to the fixture to function However Mode 5 and Mode 6 require data cables to be used Mode 6 refers to the DMX controlled opera...

Страница 7: ...r to the next and at different speeds F300 RGB fades through RGB at a speed set from 00 99 F700 7 COLOR fades through 7 standard colors at a speed from 00 99 FF00 STROBE sets the flashing speed from 00 99 Mode 4 Sound Active Display shows S000 Mode 4 uses the internal microphone to advance through the selected option from below By listening to ambient music the fixture will make changes at audio p...

Страница 8: ...the first light then from the DMX OUT to the DMX IN of the next light and so on Only one data source can be on a chain and no branching is allowed The physical order in which the fixtures are connected is not important use the most convenient Data Terminator A Data Terminator can be connected to the DMX OUT of the last fixture to reduce the effects of signal noise it is not required for all instal...

Страница 9: ...e will leave no empty channels between fixtures so the second Start Address is set to DMX channel 7 and that fixture occupies channels 7 thru 12 The third fixture will be addressed 7 6 13 and occupy channels 13 thru 18 The last fixture is addressed 13 6 19 and will occupy channels 19 thru 24 Thus 4 fixtures using 6 channels each have Start Addresses of 1 7 13 and 19 and the next free channel in th...

Страница 10: ...lor Macro Scroll DMX Value Function 0 4 No Macro or Scroll 5 9 Cool White 10 14 Lt Blue 15 19 Blue 20 24 Purple 25 29 Blue Magenta 30 34 Magenta 35 39 Hot Pink 40 44 Pink 45 49 Red 50 54 Orange 55 59 Yellow 60 64 Lime 65 69 Lt Green 70 74 Green 75 79 Teal 80 84 Cyan 85 89 Color Scroll Snap Speed 1 Fastest 90 94 Color Scroll Snap Speed 2 95 99 Color Scroll Snap Speed 3 100 104 Color Scroll Snap Spe...

Страница 11: ...roll FADE Speed 6 200 204 Color Scroll FADE Speed 7 205 209 Color Scroll FADE Speed 8 210 214 Color Scroll FADE Speed 9 215 219 Color Scroll FADE Speed 10 220 224 Color Scroll FADE Speed 11 225 229 Color Scroll FADE Speed 12 230 234 Color Scroll FADE Speed 13 235 239 Color Scroll FADE Speed 14 240 244 Color Scroll FADE Speed 15 245 249 Color Scroll FADE Speed 16 250 255 Color Scroll FADE Speed 17 ...

Страница 12: ... the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safety cables to ensure fixture is secure and safe Accessory Items sold separately Order Code Description CLAMP C Medium Duty C Clamp CLAMP MEGA B Mega Heavy Duty Aluminum Clamp CLAMP MINI P Mini Clamp Polished for 3 4 2 CLAMP MINI B Mini Clamp Black for 3 4 2 CLAMP CBHALF N Half Che...

Страница 13: ...smitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to identify the signal as a Standard DMX transmission This start code is transparent to the user and is handled by the controller The physical signals are transmitted using a twisted pair of wires and a common shield a configuration cal...

Отзывы: