DMX Start Address 

To place the fixture in DMX mode, press the MENU key, then using the UP/DOWN keys 
get to the Address Menu Option. Press  ENTER and using the UP/DOWN buttons, set 
the start address number for this particular unit in the DMX chain. Once selected, press 
ENTER again to save your selection.  More than one fixture may have the same start 
address, but they will behave the same. Giving a unique start address that does not 
overlap with any other units allows you to individually control that fixture’s features fully. 
Never allow channels to overlap.   You will need to select the number of channels you 
wish the fixture to use first.  Your choices are 3,4,5, or 6 channel modes.  This will 
determine the spacing of channels you will need to avoid overlapping of channels when 
selecting your start addresses. 

 

Example

 

Select Start Addresses for 4  fixtures each requiring 6 channels of DMX (6 

channel mode).

 

For this example, start with the first unit set to the first possible Start Address = 

1

.  This fixture 

occupies DMX channels 1 thru 6.  The next DMX channel available for a Start Address is found 
by adding the previous fixture’s Start Address to its channel requirement: 1+6=

7

.  To maximize 

channel usage, we will leave no empty channels between fixtures so the second Start Address 
is set to DMX channel 7 and that fixture occupies channels 7 thru 12.  The third fixture will be 
addressed 7+6=

13

 and occupy channels 13 thru 18.  The last fixture is addressed 13+6=

19

 and 

will occupy channels 19 thru 24.  Thus, 4 fixtures using 6 channels each have Start Addresses 
of 

1, 7, 13

 and 

19

 and the next free channel in the system is 19+6=25.  

 
 

DMX Channel Assignments 

This fixture features 4 different DMX Channel modes.  A 3, 4, 5, and 6 channel mode.  
Using the 6 channel mode provides the most features, however it takes up the most 
channels of DMX. The different channel assignments are shown below.  We will provide 
a full description of the values and functions of the 6 channel mode only. All other modes 
of less channels, do the same functions described within the 6 channel mode. 

Note that 

the channel order maybe different for each of the mode.

      

 

3 Channel Mode

  

 
 
 
 
 

 

4 Channel Mode

  

 
 
 
 
 
 

 

Channel  Function 

Red (0-255) 

Green (0-255) 

Blue (0-255) 

Channel  Function 

Red (0-255) 

Green (0-255) 

Blue (0-255) 

Master Dimmer (0-255) 

Содержание DL-LEDPAR1C36O/B

Страница 1: ...Information specifically for DL LEDPAR1C36O B Black DL LEDPAR1C36O S Silver V2 This manual contains important information Please read before operating fixture...

Страница 2: ...l not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or Techni Lux...

Страница 3: ...Connection 8 Data Terminator 8 Adapter 5 to 3 pin 8 DMX Start Address 9 DMX Channel Assignments 9 3 Channel Mode 9 4 Channel Mode 9 5 Channel Mode 10 6 Channel Mode 10 Channel Values and Functions 6 C...

Страница 4: ...ysical Color Black or Silver Size 9 5 x 11 0 x 7 25 Weight 8 5 lbs 3 86 kgs Housing Material Aluminum Environmental Location Indoor Outdoor IP65 Max ambient temperature 105 F 40 C Min distance to flam...

Страница 5: ...hipping damage resulting from inadequate packaging is the customer s responsibility Customer will be charged additional shipping charges to return products received in non original packing and or cart...

Страница 6: ...Control Panel to access the Control Menu The MENU Key puts the fixture in the settings menu itself and also acts as a BACK key between options UP DOWN moves through the menu options and allows the ass...

Страница 7: ...ress so the channels used do not overlap with other fixtures In some cases it may be desirable to set two or more same type fixtures to the same Start Address In this case the fixtures will be slaved...

Страница 8: ...Negative S and pin 3 Data positive S A qualified technician can determine if a Data Terminator is needed Adapter 5 to 3 pin Systems using 5 pin DMX interfaces can be accommodated by purchasing 3 to 5...

Страница 9: ...MX channel available for a Start Address is found by adding the previous fixture s Start Address to its channel requirement 1 6 7 To maximize channel usage we will leave no empty channels between fixt...

Страница 10: ...intensity of Green Actual value is subject to Master Dimmer channels The Color Macro Scroll Channel will override this channel Channel Function 1 Red 0 255 2 Green 0 255 3 Blue 0 255 4 Master Dimmer 0...

Страница 11: ...ow 60 64 Lime 65 69 Lt Green 70 74 Green 75 79 Teal 80 84 Cyan 85 89 Color Scroll Snap Speed 1 Fastest 90 94 Color Scroll Snap Speed 2 95 99 Color Scroll Snap Speed 3 100 104 Color Scroll Snap Speed 4...

Страница 12: ...Color Scroll FADE Speed 11 225 229 Color Scroll FADE Speed 12 230 234 Color Scroll FADE Speed 13 235 239 Color Scroll FADE Speed 14 240 244 Color Scroll FADE Speed 15 245 249 Color Scroll FADE Speed 1...

Страница 13: ...nal parts or effects 4 Clean all optical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safety cables to ensure fixtur...

Страница 14: ...mitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to identify the signal as a Standard...