Maintenance 

Make sure fixture is cool and disconnected from power mains before any service. 

 

 

Weekly operating hours and environmental conditions will establish how often the fixtures need 
cleaning.  Fixtures should be cleaned and inspected at least once a month to maintain optimum 
performance.  Accumulation of dust and fog residue increases heat build up, can lead to 
malfunctions, overheating and reduction in maximum light output, reduced fixture life and over 
all performance.  Before conducting any maintenance, disconnect fixture from power mains.   
  
1) Disconnect fixture from power mains. 
2) Use a  vacuum with a soft brush to remove dust collected on external vents and internal 
components.  If using an air compressor, use low pressures and extreme care to prevent 
damaging any internal parts or effects. 
4) Clean all optical elements when the fixture is cold.  Use a soft lint free cotton cloth or tissue 
and cleaner safe for plastics.  
5) Inspect clamps and safety cables to ensure fixture is secure and safe. 
 
 
 

Accessory Items 

(sold separately)

 

 

Order Code 

Description 

CLAMP-MEGA/B 

Mega Heavy Duty Aluminum Clamp – Black 

CLAMP-CBHALF 

Half Cheeseborough Coupler 300kg Max Load  

 

 

SAFETYCABLE18B 

Safety Cable Black 18” 

SAFETYCABLE18S 

Safety Cable Silver 18” 

 

 

DL-LEDPAR1C36OL30 

30 degree lens set 

DL-LEDPAR1C36OL45 

40 degree lens set 

DL-LEDPAR1C36OL60 

60 degree lens set 

 

 

CA-XLR3/5 

Pre-made 5’  3-pin XLR Cable 

CA-XLR3/10 

Pre-made 10’ 3-pin XLR Cable 

CA-XLR3/25 

Pre-made 25’ 3-pin XLR Cable 

CA-XLR3/50 

Pre-made 50’ 3-pin XLR Cable 

CA-XLR3/100 

Pre-made 100’ 3-pin XLR Cable 

 

 

CO-XLR3M   

XLR Connector 3-pin Male 

CO-XLR3F 

XLR Connector 3-pin Female 

 

 

CO-XLRTERM3 

XLR 3 Pin Data Terminator 

 

 

CO-XLR3MTO5F 

XLR 3 Pin Male to 5 Pin Female Adapter 

CO-XLR5MTO3F 

XLR 5 Pin Male to 3 Pin Female Adapter 

 
 

Содержание DL-LEDPAR1C36O/B

Страница 1: ...Information specifically for DL LEDPAR1C36O B Black DL LEDPAR1C36O S Silver V2 This manual contains important information Please read before operating fixture...

Страница 2: ...l not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or Techni Lux...

Страница 3: ...Connection 8 Data Terminator 8 Adapter 5 to 3 pin 8 DMX Start Address 9 DMX Channel Assignments 9 3 Channel Mode 9 4 Channel Mode 9 5 Channel Mode 10 6 Channel Mode 10 Channel Values and Functions 6 C...

Страница 4: ...ysical Color Black or Silver Size 9 5 x 11 0 x 7 25 Weight 8 5 lbs 3 86 kgs Housing Material Aluminum Environmental Location Indoor Outdoor IP65 Max ambient temperature 105 F 40 C Min distance to flam...

Страница 5: ...hipping damage resulting from inadequate packaging is the customer s responsibility Customer will be charged additional shipping charges to return products received in non original packing and or cart...

Страница 6: ...Control Panel to access the Control Menu The MENU Key puts the fixture in the settings menu itself and also acts as a BACK key between options UP DOWN moves through the menu options and allows the ass...

Страница 7: ...ress so the channels used do not overlap with other fixtures In some cases it may be desirable to set two or more same type fixtures to the same Start Address In this case the fixtures will be slaved...

Страница 8: ...Negative S and pin 3 Data positive S A qualified technician can determine if a Data Terminator is needed Adapter 5 to 3 pin Systems using 5 pin DMX interfaces can be accommodated by purchasing 3 to 5...

Страница 9: ...MX channel available for a Start Address is found by adding the previous fixture s Start Address to its channel requirement 1 6 7 To maximize channel usage we will leave no empty channels between fixt...

Страница 10: ...intensity of Green Actual value is subject to Master Dimmer channels The Color Macro Scroll Channel will override this channel Channel Function 1 Red 0 255 2 Green 0 255 3 Blue 0 255 4 Master Dimmer 0...

Страница 11: ...ow 60 64 Lime 65 69 Lt Green 70 74 Green 75 79 Teal 80 84 Cyan 85 89 Color Scroll Snap Speed 1 Fastest 90 94 Color Scroll Snap Speed 2 95 99 Color Scroll Snap Speed 3 100 104 Color Scroll Snap Speed 4...

Страница 12: ...Color Scroll FADE Speed 11 225 229 Color Scroll FADE Speed 12 230 234 Color Scroll FADE Speed 13 235 239 Color Scroll FADE Speed 14 240 244 Color Scroll FADE Speed 15 245 249 Color Scroll FADE Speed 1...

Страница 13: ...nal parts or effects 4 Clean all optical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safety cables to ensure fixtur...

Страница 14: ...mitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to identify the signal as a Standard...

Отзывы: