background image

 5

Unpacking 

Immediately upon receipt, carefully unpack and inspect the fixture to verify that all parts are 
present and have been received in good condition.  If any parts appear damaged from shipping 
or the shipping carton shows signs of mishandling, notify the shipper immediately.  Retain 
carton and all packing material for inspection.  In the event that the merchandise is to be 
returned, the original carton and packing must be used.  The customer will be billed for a new 
carton and packing if merchandise is received without the original carton and packing. 
 

Claims 

Physical damage must be reported to the Freight Carrier or Shipping Company upon 
receipt of merchandise.  Damage incurred in shipping is the responsibility of the Freight 
Carrier or Shipping Company.  It is the customer’s obligation in the event that 
merchandise is received damaged, to notify the Freight Carrier or Shipping Company 
immediately.  All other claims not related to damage incurred during shipping must be 
made to the Dealer or Distributor within 7 days of receiving merchandise.  

 

Returns 

Returned merchandise must be in the original packing with a Return Merchandise 
Authorization number (RMA) clearly listed on the shipping label.    Items sent by Freight 
Collect or without a RMA number will be refused.   Call your sales person and request a 
RMA prior to shipping.  Be prepared to provide the model number, serial number and 
description of the nature of the return.  Shipping damage resulting from inadequate 
packaging is the customer’s responsibility.  Customer will be charged additional shipping 
charges to return products received in non original packing and or cartons. 

 
 

Power 

 

Do not apply power to the fixture until power source is verified. 

 

For protection against electric shock, fixture must be connected to suitable earth ground. 
Make sure fixture is disconnected from power mains before any service. 

 
The mains voltage and frequency of this fixture is automatically set. It may operate on an input 
AC voltage ranging from 100 to 250volts, 50/60Hz.  The listed power rating is its average 
wattage under normal conditions. All fixtures must be powered directly from a switched circuit.  
This fixture cannot be run on a rheostat or dimmer circuit even if used solely for a 0% to 100% 
switching.  Before applying power to a fixture, check that the fixture’s input voltage matches the 
power source voltage.  Consult a qualified electrician if there are any concerns about proper 
connection to power. 
 

Mounting 

Always consult a qualified professional when rigging.  Consider access for routine maintenance 
when selecting a mounting position. This fixture may be mounted in any position provided there 
is adequate room for movement and ventilation.  Mount the fixture securely using a mounting 
clamp and a safety cable. Always keep cords out of the way, thus preventing any trip hazards. 
Secure all cables properly. Do not mount where the fixture will be exposed to extreme 
temperature changes or restricted ventilation.  Do not obstruct any vents. 

 

Содержание DL-LEDIF98QO

Страница 1: ...Information specifically for DL LEDIF98QO V1 0 This manual contains important information Please read before operating fixture...

Страница 2: ...ited to and shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the deal...

Страница 3: ...ddress 9 DMX Channel Assignments 9 4 Channel Mode 9 6 Channel Mode 10 7 Channel Mode 10 Channel Values and Functions 7 Channel Mode 10 CH 1 Master Dimmer 10 CH 2 Strobe 10 CH 3 Red 11 CH 4 Green 11 CH...

Страница 4: ...Housing Material Aluminum casting and Stainless steel hardware Environmental Location Indoor Outdoor IP65 Max ambient temperature 105 F 40 C Min distance to flammable surface 3 3ft 1m Min distance to...

Страница 5: ...scription of the nature of the return Shipping damage resulting from inadequate packaging is the customer s responsibility Customer will be charged additional shipping charges to return products recei...

Страница 6: ...D Display Menu Setting Buttons Setup and Operation Modes LCD Display The following refers to the different modes that are available on this fixture via the LCD Control Panel display All functions are...

Страница 7: ...xtures requiring more than one channel for control will read subsequent channels up to the total number of channels required Since this fixture requires a maximum of 7 channels of DMX if set to a Star...

Страница 8: ...watt resistor across pin 2 Data Negative S and pin 3 Data positive S A qualified technician can determine if a Data Terminator is needed Adapter 5 to 3 pin Systems using 5 pin DMX interfaces can be ac...

Страница 9: ...hru 7 The next DMX channel available for a Start Address is found by adding the previous fixture s Start Address to its channel requirement 1 7 8 To maximize channel usage we will leave no empty chann...

Страница 10: ...present value Channel Function 1 Red 0 255 2 Green 0 255 3 Blue 0 255 4 White 0 255 5 Master Dimmer 0 255 6 000 000 On No Function 001 005 Off No output 006 010 On 011 255 Strobe slow to fast Channel...

Страница 11: ...Color Macro Scroll The Color Macro Scroll scrolls between 15 colors either by snapping from one color to the next or by fading This will override the relative values set by the individual RGBW channe...

Страница 12: ...adjust via to select the 3 scenes FL Flash on off adjust speed via SP Speed control via to adjust the color change speed and dream fade speed D DMX mode SA Not in use SL Master slave mode S Setting DM...

Страница 13: ...ical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safety cables to ensure fixture is secure and safe Accessory Items...

Страница 14: ...all channels are transmitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to identify the...