Basic Reference
Setup & Operation Modes
For this fixture to operate correctly you must first set the dip switches to the desired operation
mode. This tells the fixture how it is to perform and what signals (if any) it is to respond to. When
DIP Switch #10 is in the OFF position, the remaining switches Dips 1-9 can be used to set the
fixture in various stand-alone modes. Stand-alone refers to using the fixture without a controller.
Stand-alone Mode
With Dip 9 OFF & Dip 10 OFF:
Dip 1 - Dip 4 to select different built-in running programs.
Dip 5 – Dip 6 allows adjustment of the color change speed.
Dip 7 – Dip 8 adjusts the strobe flash speed.
Sound-active Mode
With Dip 9 ON and Dip 10 OFF:
Dip 1 – Dip 4 set the sound sensitivity.
Master / Slave Mode
With Dip 10 set to ON, and all other dipswitches set to OFF, the unit will go into SLAVE
mode and follow the master unit. Standard DMX interconnect cables between fixtures is
required for this mode to operate.
DMX Controlling Mode
Set Dip 10 to ON, and use Dips 1-9 to set the start address. Refer to the section titled,
“DMX Control Mode”.