11
DMX Start Address
To place the fixture in DMX mode, press the MENU key, then using the UP/DOWN keys
get to the Address Menu Option. Press ENTER and using the UP/DOWN buttons, set the
start address number for this particular unit in the DMX chain. Once selected, press
ENTER again to save your selection. More than one fixture may have the same start
address, but they will behave the same. Giving a unique start address that does not
overlap with any other units allows you to individually control that fixture’s features fully.
Never allow channels to overlap. You will need to select the number of channels you
wish the fixture to use first. Your choices are 3,4,5, or 6 channel modes. This will
determine the spacing of channels you will need to avoid overlapping of channels when
selecting your start addresses.
Example
Select Start Addresses for 4 fixtures each requiring 6 channels of DMX (6
channel mode).
For this example, start with the first unit set to the first possible Start Address =
1
. This fixture
occupies DMX channels 1 thru 6. The next DMX channel available for a Start Address is found
by adding the previous fixture’s Start Address to its channel requirement: 1+6=
7
. To maximize
channel usage, we will leave no empty channels between fixtures so the second Start Address is
set to DMX channel 7 and that fixture occupies channels 7 thru 12. The third fixture will be
addressed 7+6=
13
and occupy channels 13 thru 18. The last fixture is addressed 13+6=
19
and
will occupy channels 19 thru 24. Thus, 4 fixtures using 6 channels each have Start Addresses of
1, 7, 13
and
19
and the next free channel in the system is 19+6=25.
Maintenance
Make sure fixture is cool and disconnected from power mains before any service.
Weekly operating hours and environmental conditions will establish how often the fixtures need
cleaning. Fixtures should be cleaned and inspected at least once a month to maintain optimum
performance. Accumulation of dust and fog residue increases heat build up, can lead to
malfunctions, overheating and reduction in maximum light output, reduced fixture life and over
all performance. Before conducting any maintenance, disconnect fixture from power mains.
1) Disconnect fixture from power mains.
2) Use a vacuum with a soft brush to remove dust collected on external vents and internal
components. If using an air compressor, use low pressures and extreme care to prevent
damaging any internal parts or effects.
4) Clean all optical elements when the fixture is cold. Use a soft lint free cotton cloth or tissue
and cleaner safe for plastics.
5) Inspect clamps and safety cables to ensure fixture is secure and safe.