background image

Spider810 

 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 

Information specifically for:

 

 

 DE-Spider810         
 

V0 

 
 

This manual contains important information.

Please read before operating fixture.

Содержание DE-Spider810

Страница 1: ...Spider810 Information specifically for DE Spider810 V0 This manual contains important information Please read before operating fixture ...

Страница 2: ...ll not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or Techni Lux directly to obtain an RMA The RMA number must be clearly listed on the shipping label Due care must be exercised in packing all merchandise to be returned All repairs must be accompanied by a writte...

Страница 3: ...rol Panel Menu 6 Control Panel Menu Table 6 DMX Channel Layout 8 7 Channel DMX Mode 8 12 Channel DMX Mode 9 DMX512 Control 10 DMX Data Connection 10 Data Terminator 10 Adapter 5 to 3 pin 10 DMX Start Address 11 Maintenance 11 Accessory Items sold separately 12 Troubleshooting 12 DMX 512 Background 13 ...

Страница 4: ... Size 16 x 9 25 x 6 405 x 235 x 150 mm Weight 12 1 lb 5 5 kg Environmental Location Indoor IP20 Max ambient temperature 105 F 40 C Min distance to flammable surface 3 3ft 1m Min distance to illuminated surface 1ft 0 3m Electrical Voltage Auto Ranging 90 250vAC 50 60Hz Rated Power 120W Control Digital Protocol USITT DMX512 1990 Channels 7 or 12 Data I O 3 Pin XLR Cannon Modes DMX512 Sound or Master...

Страница 5: ...erial number and description of the nature of the return Shipping damage resulting from inadequate packaging is the customer s responsibility Customer will be charged additional shipping charges to return products received in non original packing and or cartons Power Do not apply power to the fixture until power source is verified For protection against electric shock fixture must be connected to ...

Страница 6: ...rating through a DMX controller gives the user full control over all effects and the freedom to create custom programs To run unit in DMX mode connect data via the 3 pin XLR connection to any standard DMX controller Set desired DMX start address following the setup specifications that come with your DMX controller 1 This function will allow you to control each individual unit s traits with a stand...

Страница 7: ...esired operating mode 7 or 12 Channels Use the up down keys to select Press Enter to confirm Function sets Master Slave mode Use the up down keys to select Press Enter to confirm Function activates Sound Control Use the up down keys to select Press Enter to confirm Function selects if panel backlight stays ON OFF Use the up down keys to select Press Enter to confirm Function flips display between ...

Страница 8: ...MX Channel modes 7 or 12 Using the 12 Channel mode provides the most features however it takes up the most channels of DMX The different channel assignments are shown below Note that the channel order maybe different for each of the modes 7 Channel DMX Mode ...

Страница 9: ...9 12 Channel DMX Mode ...

Страница 10: ...wisted pair cable approved for EIA 422 EIA485 use Fixtures are connected in Daisy Chain topography Connection is made from the controller to the DMX IN of the first light then from the DMX OUT to the DMX IN of the next light and so on Only one data source can be on a chain and no branching is allowed The physical order in which the fixtures are connected is not important use the most convenient Da...

Страница 11: ...eave no empty channels between fixtures so the second Start Address is set to DMX channel 7 and that fixture occupies channels 7 thru 12 The third fixture will be addressed 7 6 13 and occupy channels 13 thru 18 The last fixture is addressed 13 6 19 and will occupy channels 19 thru 24 Thus 4 fixtures using 6 channels each have Start Addresses of 1 7 13 and 19 and the next free channel in the system...

Страница 12: ... 5 Pin Male to 3 Pin Female Adapter Troubleshooting Symptom Possible Cause Solution No Power Check for power on mains Check main fuse and fuse holder Erratic No response to DMX Check Start Address Check that unit is in expected channel Mode Check data cables connection and proper wiring Incorrectly responds to DMX Diagnostic technique Set Start Address of suspect fixture to same as working fixture...

Страница 13: ...d by the controller The physical signals are transmitted using a twisted pair of wires and a common shield a configuration called Balanced The controller and all receiving equipment are connected using a Daisy Chain connection The signal is jumped from the controller to a piece of DMX equipment From there the signal is jumped to the next piece of equipment and so on until the last piece of equipme...

Отзывы: