4  Module Characteristics 

4.1  Module Appearance and Port Layout 

4.1.1  Overview 

 

Figure 4-1

 

Module Appearance

  

 

Front Panel 

Rear Panel 

Figure 4-1 module appearance

4 Module characteristics

4.1 Module appearance and port layout
4.1.1 Overview

Содержание AIMA-FPAS

Страница 1: ...AIMA FPAS RF FORWARD PATH AMPLIFIER STANDARD Online Email customer service vdl technetix com Website technetix com 2018 08 EN V2 Technetix Group Limited Product user manual...

Страница 2: ...m 5 3 4 Order details 6 4 Module characteristics 6 4 1 Module appearance and port layout 6 4 1 1 Overview 6 4 1 2 FPAS S Front panel layout 7 4 1 3 FPAS S Rear panel layout 8 4 1 4 FPAS D Front panel...

Страница 3: ...alarm 15 6 2 3 Module port alarms 16 6 2 4 Alarm monitoring configuration 17 6 2 5 Input Output status monitoring 18 6 3 Logs management 19 6 4 Device upgrade 20 6 5 Restoring factory defaults 21 6 6...

Страница 4: ...cumentation The following documents may be used in conjunction with this manual AIMA3000 Product user manual AIMA ASMM Product user manual AIMA3000 NMS web management system product user manual NMS3 E...

Страница 5: ...time there may be dangerous voltage inside the device DO NOT power up before the cover and the panels of the equipment are installed and the enclosure is closed Cleaning Only use a damp cloth to clean...

Страница 6: ...ained in non volatile memory to ensure trouble free operation Bulk updating automatic uploading and downloading of configuration files can be done when using the NMSE web based management system 3 2 P...

Страница 7: ...dB RF test point relative to RF output port 20 1 dB RF connectors Single 2 x GSK type female Dual 4 x GSK type female RF test points 2 x mini SMB Alarms and status Front panel LEDS SNMP traps Path iso...

Страница 8: ...3 1 Block diagram FPAS S Figure 3 2 block diagram FPAS D Table 3 1 FPAS S block diagram glossary Parameters Glossary RF INPUT RF input ATT Attenuator TP RF IN 20 dB RF 20 dB input test point SLOPE Sl...

Страница 9: ...in Output gain TO BACKPLANE AND COMMS Data bus CPU Central processing unit Parameters Glossary RF INPUT1 RF1 input RF INPUT2 RF2 input ATT Attenuator TP RF IN 20 dB RF 20 dB input test point SLOPE Slo...

Страница 10: ...al Pacific Broadband Networks 15 January 2015 Page 11 of 36 4 Module Characteristics 4 1 Module Appearance and Port Layout 4 1 1 Overview Figure 4 1 Module Appearance Front Panel Rear Panel Figure 4 1...

Страница 11: ...ndicator Normal Green Minor alarm Amber Major alarm Red 3 RF IN LED RF input Normal Green Minor alarm Amber Major alarm Red 4 RF IN TP RF input test point 5 RF OUT LED RF output indicator Normal Green...

Страница 12: ...re 4 3 FPAS S rear panel layout Table 4 2 FPAS S rear panel functions Item Number Item Description 1 RF IN RF input 2 RF OUT RF output 3 Air vent Air vent allowing air to flow out of the module 4 Mult...

Страница 13: ...IN LED RF1 input Normal Green Minor alarm Amber Major alarm Red 4 RF1 OUT LED RF1 output indicator Normal Green Minor alarm Amber Major alarm Red 5 RF IN TP RF1 input test point Item Number Item Desc...

Страница 14: ...el layout Table 4 4 FPAS D rear panel functions Item Number Item Description 1 RF1 IN RF1 input 2 RF1 OUT RF1 output 3 RF2 IN RF2 input 4 RF2 OUT RF2 output 5 Air vent Air vent allowing air to flow ou...

Страница 15: ...quipment and tools for installation Table 5 1 Necessary equipment and tools for installation 5 2 Unpacking Unpack the module Keep the packaging materials for future transport needs Check the package m...

Страница 16: ...it reaches the multi pin connector DO NOT use excessive force when inserting the module but ensure the RF connectors at the rear of the module are securely connected with the chassis s RF connectors...

Страница 17: ...ounting screw Only use fingers to fasten the mounting screw DO NOT use a screwdriver 5 4 Check module LEDs When the module has been installed and power is supplied from the chassis the status LEDs wil...

Страница 18: ...on the web interface For login details and network setup please refer to the AIMA ASMM user manual If the same module is reinserted in the same slot the ASMM will restore the previous settings if the...

Страница 19: ...for the designated transmitter In the FPAS Port configuration screen Output Gain Control Slope Control Input Gain Control Gain Control Type and Alarm Settings become available Total Gain is calculated...

Страница 20: ...e If an alarm occurs the operator can view the associated module page to find more detailed alarm information 6 2 1 Alarm status pages Click the Alarms tab on the top menu bar to display an overview o...

Страница 21: ...By clicking on FPAS under Modules tab the operator can view the module temperature and power supply voltage alarms The operator can utilise the status indicators to judge whether the module is working...

Страница 22: ...MA FPAS 6 2 3 Module Port Alarms Click on the Port label under the selected module on the left column On the module Port page the operator can view the Input Power Output Power and the AGC Status alar...

Страница 23: ...l to toggle the monitoring function Temperature 12V 5V Voltage Alarm Levels Management By default temperature 12 V and 5 V alarms are all set to ON The check box as shown in Figure 6 6 toggles detecti...

Страница 24: ...Product user manual AIMA FPAS Parameter HIHI HI LO LOLO Deadband Threshold changeable Default Alarm Enable Temperature oC 70 0 65 0 0 0 5 0 2 0 NO YES 12V Input Voltage V 13 5 10 5 0 2 NO YES 5V Inpu...

Страница 25: ...ut Status Monitoring To setup Input Output status monitoring select the Port label from the left menu under the desired module and then the monitoring parameters will be listed the in the Alarm Settin...

Страница 26: ...Power ON During Module Power ON All Green 2 times sec No Alarm Normal operation Normal All Green Upgrading AM Firmware AM Upgrading Module upgrade MODE AM Critical ALM Critical Alarm STAT Red AM Mino...

Страница 27: ...eeds to be located on a PC that is connected to ASMM The web GUI above only supports the manual operation from a local PC The FPAS supports automated firmware updates and automatic backup restore feat...

Страница 28: ...ns Click the Modules tab on the top menu and click the module to be configured on the left menu Click the Apply button in the Factory Defaults section When finished the device configuration will be re...

Страница 29: ...ettings Table 6 4 Factory default and upgrade configuration parameters table Parameters Configuration Factory default value Alarm Control Enable Disable Enable Gain Control Type AGC MGC MGC Slope Cont...

Страница 30: ...the Modules tab on the top menu then click the corresponding FPAS module from the left menu and click the Apply button in Reboot section Next click on Submit to confirm and then the module will autom...

Страница 31: ...TAT is amber Operating environment temperature is lower or higher Check the fans or lower the room temperature If the temperature is normal please contact Technetix s technical support 12V 5V Input vo...

Страница 32: ...0 0 5 0 2 0 ON 20 125 5V input Voltage V 6 5 0 4 4 0 1 ON 0 6 5 12V input Voltage V 13 5 12 0 10 5 0 2 ON 0 16 Appendix A Default alarm limit settings Appendix B Factory default settings Parameters C...

Страница 33: ......

Отзывы: