background image

 

 

 

 

 

 

 

 

Safegua

rds 

 

Terms and

 

Warranty 

Principl

e o

Operati

on

 

Ins

talla

tion

 

Operati

on

 

C

ont

rol Syst

em

 

RF Componen

ts 

Power

 Supp

ly 

Maintenan

ce

 

10 

Troubleshoo

ting

 

Display Interface Module 
REV 1.02 (ASY 016) 
Touchscreen Option 

 
The primary function of the Display Interface module is, as the name suggests, 
providing the display and user interface for the control system. This circuit board 
is mounted behind the front panel of the power amplifier enclosure(s) in the 
amplifier system, near the 4.3” touchscreen or OLED display. All switch/settings 
and user interface is handled through the resistive touchscreen. The touchscreen 
on the front panel is connected to the Display Interface PCB through a cable. 
 
These components provide the user with the ability to monitor the following 
power amplifier or transmitter parameters from the front panel: 
 

•  Forward (incident) power at the power amplifier or transmitter output. 
•  Reflected (reverse) power at the power amplifier or transmitter output. 
•  DC voltage of the power amplifier’s or transmitter’s power supply. 
•  DC current in the power amplifier or transmitter. 
•  Temperature of the heat sink of the power amplifier or transmitter. 
•  The time since the amplifier or transmitter was last shut down. 
•  History of faults and events. 
•  Indication if there is attenuation added to the front end of the power 

amplifier or transmitter indicating  fold back in RF power (indicates amount 
of attenuation). 

•  Settings to change the VSWR trip point shutdown between 1.1:1 and 

1.8:1. 

•  Settings to change the RF power units between % power (maximum of 

110%) or watts. 

•  Summary of PCB modules and assembly numbers specific to the power 

amplifier or transmitter. 

 
A block diagram of the Display Interface PCB follows: 

 
 
 
 
 
 
 
 
 
 
 
 

Содержание TXF-1000

Страница 1: ...FM TRANSMITTER...

Страница 2: ...every attempt to educate readers of all technical levels If there is something that is not clear or you require further information please do not hesitate to contact us and we ll be glad to help out...

Страница 3: ...d be observed by personnel using this or other electronic equipment Documentation Read retain and follow instructions before operating the equipment There is a lot of useful information in the manual...

Страница 4: ...ple degrees of burns recognizable as follows a first degree burn reddens the skin a second degree burn blisters the skin a third degree burn chars the flesh and frequently places the victim in a state...

Страница 5: ...Before anything is turned on ensure that there is a 50 ohm path from the output of each stage to the input of the next all the way to the antenna Operating Warnings Our FM equipment is designed to re...

Страница 6: ...d by Seller of any of the terms or conditions hereof shall be deemed a continuing waiver or trade custom between parties but shall apply solely to the instance to which the waiver is directed Ordering...

Страница 7: ...n Seller consent All changes must be included in change order reflecting purchase order and submitted to the Seller All other changes will not be accepted acknowledged Changes may affect delivery date...

Страница 8: ...elivery or failure to deliver which is due to any cause beyond Seller s control including without limitation acts of nature unavailability of supplies or sources of energy riots wars fires floods epid...

Страница 9: ...the practices of untrained or unqualified personnel in the handling of this equipment and does not include misuse neglect or accident incorrect wiring and or improper installation unauthorized repair...

Страница 10: ...mplifier systems the pattern of the antenna then dictates the range and coverage area The amplification is accomplished by one or many amplifier pallets internal to the power amplifier system If there...

Страница 11: ...licensed local electrician be consulted for the required electrical service We suggest local electricians because The personnel knows the local codes The personnel can be on site readily You are apt...

Страница 12: ...ll coaxial cables in the system input and output Pay attention to radial ice accumulation when designing the transmission system It is not uncommon for at least an inch of ice to build up on a tower o...

Страница 13: ...be stuffed with steel wool and caulked to prevent entry of wildlife Other features of security for your shelter may include its location with respect to the prevailing wind conditions Locations leewar...

Страница 14: ...ent or warped chassis loose screws or nuts or extraneous packing material in connectors or fan failures Inspect all connectors for bent connector pins If the equipment is damaged a claim should be fil...

Страница 15: ...Ethernet RJ45 jack SNMP Simple Network Management Protocol SNMP remote control and monitoring RJ45 S PDIF COAX Digital audio input Sony Phillips Digital Interface coaxial RCA female S PDIF OPTICAL Dig...

Страница 16: ...permanent location near a receptacle supplying the required AC or DC mains voltage 3 Place an appropriate AC or DC power line protector conditioner and or surge suppressor across the supply line This...

Страница 17: ...or MPX Subcarrier signals can be connected to the SCA1 or SCA2 BNC connectors 7 Connect additional control monitoring cables if desired SNMP or Ethernet should be connected to the lower RJ45 on the ba...

Страница 18: ...e power amplifier fans are powered via DC voltage so this is an indication that the power supply is started and running There may be fans installed in the filter or power supply enclosures if applicab...

Страница 19: ...upplied final inspection sheet for factory settings of power supply levels on the display of the power amplifier You should see no more than 3 fluctuations in DC supply voltage and even less with a pr...

Страница 20: ...he receiving antenna or with obstructions in the path between the amplifier antenna and receiver There is also a troubleshooting section located later in this manual At this time Technalogix recommend...

Страница 21: ...r from both the front panel and remotely through the parallel port Ethernet or SNMP access port The control system is comprised of three modules These modules work together to provide all the function...

Страница 22: ...CTION METER METER DEVIATION RF AMP RF LEVEL CANbus CONTROL INTERFACE RF OUT LEVEL LEVEL FILTER LEVEL FILTER RECEIVER DIG AUDIO ENCODER STEREO LEVEL EMPHASIS PRE BALUN TERM I P FILTER RHT MONO FILTER F...

Страница 23: ...o monitor the following power amplifier or transmitter parameters from the front panel Forward incident power at the power amplifier or transmitter output Reflected reverse power at the power amplifie...

Страница 24: ...emperature of the amplifier transmitter as well as relay commands from the user to the rest of the system If the DC Distribution Module is installed on higher power systems with multiple pallets then...

Страница 25: ...escribed later in this section Summary Bar The summary bar at the bottom of the screen will stay in place no matter what screen is being viewed to allow for an operating summary at any time as describ...

Страница 26: ...predetermined level to keep the amplifier transmitter pallets safe Should a fan fail inside the power amplifier transmitter enclosure or air conditioning fails inside the broadcast facility causing t...

Страница 27: ...in increments of 1 or 10 Carrier Switch From any screen the FM amplifier or transmitter carrier can be turned on or off to facilitate adjustments settings and testing troubleshooting To toggle carrie...

Страница 28: ...solator installed within the enclosure it is important to minimize VSWR with a good quality antenna installed using proper broadcast techniques Ice build up on the antenna and damages to 50 ohm transm...

Страница 29: ...this level bar Typical maximum deviation required by Industry Canada or FCC is 75 kHz to avoid bleeding into adjacent channel bands of 200kHz bandwidths 100 represents a full 75 kHz deviation RIGHT LE...

Страница 30: ...icons on the Menu Screen allow the user to take additional readings or make settings that are not provided from the Main RF and FM Screens Any changes to settings will be stored in non volatile memor...

Страница 31: ...anged from the Settings screen From the RF Levels screen the user can also toggle between AGC and Manual mode The RF Levels Screen is displayed below To adjust Forward RF Level Press the up or down ar...

Страница 32: ...reen and on the summary bar at the bottom of the touchscreen should not vary more than 2 If multiple amplifier pallets are included in the amplifier chain then the individual currents will all be disp...

Страница 33: ...analog and digital audio inputs as standard the user can change audio input sources on the fly and can switch between analog and digital audio sources When digital audio is selected the Mono Stereo se...

Страница 34: ...ck around Pre Emphasis Pre emphasis adds a boost to high frequencies in the FM signal to increase the signal above the noise floor The FM signal then is de emphasized at the radio receiver end Users c...

Страница 35: ...format of the History Screen is illustrated below Ten of the most recent events are displayed on the History Screen As more events occur the earliest recorded event gets displaced on the screen The us...

Страница 36: ...ce 10 Troubleshooting Audio Levels Screen The Audio Levels Screen allows the user to tweak audio input levels all from the front touch screen Step sizes will vary from 0 5 dB up to 2 0 dB depending on...

Страница 37: ...al years down the road The versions can then be correlated to factory documentation In addition current government certification numbers are included for Industry Canada and FCC Please contact Technal...

Страница 38: ...rovides an easy means for the user to get in touch with Technalogix for anything Whether they have a technical or installation question or simply want to chat about how gosh darn cool our equipment is...

Страница 39: ...power readings When in percentage mode the power amplifier or transmitter is designed for a maximum operating power of 100 with overdrive protection typically at 110 To change the VSWR Shutdown Trip...

Страница 40: ...rature readings of the heatsink The following is a block diagram of the Temperature Sensor module The temperature sensor IC is U701 which after it has taken a reading relays the digital information to...

Страница 41: ...Amplifier Transmitter to your Network PC Connect an Ethernet cable from the RJ45 port labelled ETH SNMP use bottom connector on the back panel of the power amplifier or transmitter to your network s...

Страница 42: ...accessed until you have established basic communication with the power amplifier or transmitter turned on 2 1 Web Page Password Protection After entering the above internal address into a web browser...

Страница 43: ...on or off Forward RF in Overdrive 110 Full Scale FS High VSWR Pallet Voltage Supply Good RF In Level Good High Temperature The Performance section provides the user with specific parameters and measu...

Страница 44: ...g Turn Carrier On Off Turn the Carrier on off AGC Increase the Carrier by removing attenuation steps of 1 or 10 dB VSWR Increase or Decrease the VSWR Trip point by 0 1 between 1 1 1 and factory determ...

Страница 45: ...on the main web Ethernet page along the top are links to the other user parameter pages Main Returns to Main Index page Network Configuration SNMP Configuration Password Configuration The following s...

Страница 46: ...careful changing HTTP ports as it can be difficult to go back to an original port You can force a web browser to use port 81 by address to http adrenaline 81 index htm To use this with an internet ad...

Страница 47: ...stem 7 RF Components 8 Power Supply 9 Maintenance 10 Troubleshooting 3 2 SNMP Configuration 3 2 1 SNMP Communities The SNMP Configuration page allows you to set the SNMP communities Set these to limit...

Страница 48: ...ag for high VSWR Overdrive error flag for overdrive Temperature Flag error flag for high temperature Preemphasis 0 25 50 or 75 us Read Write Reset 1 Reset System 0 Normal Carrier On 1 Carrier On 0 Car...

Страница 49: ...Components 8 Power Supply 9 Maintenance 10 Troubleshooting 3 2 3 SNMP Traps To enable the SNMP traps within the MIB browser that you choose Set enable traps to 1 or yes depending on MIB browser Set t...

Страница 50: ...sure that your receiver s port is set to 162 The system will generate a general trap on any error flag and send an 8 bit value indicating the type of error as follows Bit 0 LSB Overdrive Bit 1 High VS...

Страница 51: ...ation This page allows the setting of the web browser s User or Admin password as illustrated below The User account allows access only to the main page The Admin account allows access to the main and...

Страница 52: ...2 10 Do not use 11 High temperature flag2 12 High VSWR flag2 13 Amplifier overdriven flag2 14 Do not use 15 3 3Vdc for testing only do not load 16 Ground 17 Ground 18 25 Do not use Notes 1 Analog outp...

Страница 53: ...to transmit time station identification programming information and more To control the RBDS RDS connect to the DB9 on the back of the unit using a RS232 connection A USB to RS232 or Ethernet to RS232...

Страница 54: ...evels are absolute maximum levels Technalogix operates the pallets at reduced levels to improve performance and increase reliability PB1A 50 1000 1042H Typical gain 21 5 dB Pout max NTSC 1 W peak sync...

Страница 55: ...onents 8 Power Supply 9 Maintenance 10 Troubleshooting PB25C 86 110 xxx Typical gain 40 dB Pout max 8VSB 25 W rms Frequency 88 108 MHz Pin max 10 dBm ID max 1 6 Adc VD 28 Vdc PB1200C 86 110 574 Typica...

Страница 56: ...RF signal into and combine the amplified RF signal out of the final amplifier pallets within an amplifier transmitter enclosure The splitter and combiner can be 2 3 or 4 way depending on how many fin...

Страница 57: ...lly the RF output connector on the back panel of the enclosure On higher power systems high power handling connectors are used especially in the overall output combiner On lower power systems the coup...

Страница 58: ...86 110 MHz Input Power max 250 W continuous Insertion Loss max 0 3 dB Insertion Loss typ 0 25 dB Return Loss max 25 dB Return Loss typ 28 dB Rejection at 176 MHz 45 dB 800W LPF no coupler Frequency R...

Страница 59: ...MHz Input Power max 1 500 W continuous Order 9 th order Chebyshev Insertion Loss max 0 12 dB Insertion Loss typ 0 1 dB Return Loss max 28 dB Return Loss typ 33 dB Rejection at 176 MHz 47 dB Directivit...

Страница 60: ...supply The specific DC system voltage is found in the Final Inspection Report and the model and number of power supplies is documented in the Block Diagram supplied in the Quickstart package AC is fe...

Страница 61: ...tures RSP 2000 series DC OK SIGNAL REMOTE SENSE REMOTE ON OFF CONTROL AUXILIARY POWER The isolated TTL signal out refer to function manual Compensate voltage drop on the load wiring up to 0 5V refer t...

Страница 62: ...Terminal HRS DF11 SC or equivalent 3 M4 L 6 3 M4 L 6 PFC fosc 110KHz PWM fosc 90KHz LIMITING ACTIVE CURRENT INRUSH CONTROL I P RECTIFIERS FILTER SWITCHING POWER RECTIFIERS FILTER EMI PWM CIRCUIT DETEC...

Страница 63: ...2000W Single Output Power Supply RSP 2000 series File Name RSP 2000 SPEC 2012 06 04 Function D of CN501 escription Function D of CN502 escription Function D of CN504 escription Pin No 1 2 5 6 11 12 N...

Страница 64: ...3 4 4 7 5 V 40 60 80 100 115 V 100 40 60 87 20 OUTPUT CURRENT OUTPUT VOLTAGE 20 Non Linear Function DC OK DC NG T OK T ALARM LED GREEN RED RED GREEN Description When output voltage 80 5 of Vo rated Wh...

Страница 65: ...ion ripple of the output voltage may be higher than the SPEC at light load condition It will go back to normal ripple level once the output load is more than 5 8 CN502 CN504 Function pin connection V...

Страница 66: ...urn the system off and unplug all of the AC inlet cords Remove the top lid by unscrewing the 6 32 machine screws Use extreme caution when working near the AC input terminal The power amplifier transmi...

Страница 67: ...physical inspection of the entire facility Are all necessary connections properly made Do you see any signs of obvious damage within the equipment Is the AC power ON to the site and the equipment Che...

Страница 68: ...n PSU input NO Faulty AC connection entry switch or breaker DC voltage present on PSU output YES Disconnect DC loads tape off so they do not short out to see if DC output loaded down Proper DC voltage...

Страница 69: ...rol PCBs secure Contact Technalogix for further information Power supply display data accurate Remote port working correctly Goto page 2 of 2 YES YES YES DC or RF from dir coupler correct Display pins...

Страница 70: ...ce functioning SNMP interface functioning Communication between PCBs working CAN Contact Technalogix for any issues not listed YES Display Interface orange S W LED flashing NO Is FWD RFL or DC voltage...

Страница 71: ...mponents 8 Power Supply 9 Maintenance 10 Troubleshooting Thank you for choosing Technalogix Ltd If there is anything we can do to help in your success please do not hesitate to contact us We also welc...

Отзывы: