background image

TL-SSF-TESTK-1

SSF™ Fiber Test Kit

Manual

Содержание SSF Multimode Light Source

Страница 1: ...TL SSF TESTK 1 SSF Fiber Test Kit Manual ...

Страница 2: ...Warning To avoid risk of eye damage do not look into the laser when unit is on Laser does not operate at visible wavelength Light will not be visible when laser is active ...

Страница 3: ...held Optical Light Source Overview 5 Functions 7 Maintenance and Troubleshooting 10 Warranty 11 Handheld Optical Power Meter Overview 12 Specifications 14 Functions 15 Maintenance and Troubleshooting 17 Warranty 18 ...

Страница 4: ...ce 1 Do not look into the laser beam when unit is on 2 To prevent damage to the instrument do not use under high temperature high pressure wet or other prohibited conditions 3 Do not attempt to take apart or repair the instrument WARNING Quality Assurance Note SSF Single Mode Optical Light Source SSF Multimode Optical Light Source ...

Страница 5: ...e fiber Together with the SSF power meter the optical light source provides an accurate test solution for single mode and or multimode optical fiber networks Single to tri wavelength combination Continuous and modulated signal Real time display of battery level and low power indication Back light function Auto shut off function Alkaline battery operation Model SSF Single Mode Light Source Waveleng...

Страница 6: ...Temperature C 25 70 0 to 95 RH no condensation Battery Life h 40 Dimension mm in 125x65x29 4 92x2 56x1 14 Weight g oz 160 3 74 Type SSF Multimode Light Source Wavelength nm 850 1300 Emitter Type FP LD Output Power dBm 7dBM 850 1300nm Output Power 0 04 20 C 15 min Modulation CW 270Hz 1KHz 2KHz others Fiber Type MM Connector SC Power Supply AAA 1 5V 3pcs batteries Operating Temperature C 10 50 0 to ...

Страница 7: ... Shut Off Selection While unit is on press this key quickly to turn the auto shut off function on or off When auto shut off is active the unit will auto matically shut off after ten minutes idle 3 Wavelength Selection Press this key to change the wavelength shown in top left corner of screen 4 Modulation Press this key to switch modulation between continuous and modulated light Modulated light fre...

Страница 8: ...hen battery power in use The capacity shown will decrease with battery power Replace batteries as needed 3 Auto Shut off The light source will automatically shut off when idle for ten minutes Press power button quickly to turn Auto Off function on or off 4 KHz Frequency KHz 0 27 1 00 or 2 00 KHz Dashed line indicates Continuous Wave Mode CW 5 dBm Output Power dBm 1 2 5 3 4 ...

Страница 9: ...any key to reactivate 1 If the battery level is low turn off the unit immediately and replace the batteries 2 Remove the batteries if light source is not in use for an extended period of time Turning the Unit On Off Battery Replacement 1 Press to choose wavelength 2 Press to select modulation 3 The light source will output the desired laser settings Laser Output Warning 1 Do not look into the lase...

Страница 10: ...iods of time Troubleshooting Issue Possible Reason Solution Faint screen display No backlight Low battery power Replace the batteries Unit fails to turn on Low battery power or battery inserted incorrectly A Replace the battery B Re insert the battery Display fails to appear Low battery Restart or replace batteries LCD screen will not change Low battery Replace batteries No laser power Laser is of...

Страница 11: ...pair or refund the purchase price of the product The worth of the repair or replacement will not be higher than purchasing price of this unit 2 If device issues cannot be solved by the troubleshooting methods please contact us or the local distributor directly 3 We will repair or replace the unit free of charge in case of defects in production workmanship or material This warranty only applies to ...

Страница 12: ...er 1 When using light source with power meter do not look into the laser beam when unit is on Light emitted is infrared and not visible to the human eye To avoid the risk of eye damage do not look into the laser at any time when the unit is active Warning ...

Страница 13: ...mode fibers Features High measurement accuracy and display resolution Quick response and measurement real time display of output power Wide measurement range 80dB Six calibrated wavelengths Absolute and relative power measurements Real time monitoring and display of batter level Auto shut off function Backlight function Alkaline battery operation Model Wavelength 850 1300 1310 1490 1550 1625nm Mea...

Страница 14: ...gth nm 850 1300 1310 1490 1550 1625 Resolution dB Linearity 0 1 Non linearity 0 01 dBm Optical Connector SC LC with Adapters Power Supply Alkaline Battery 3 AAA 1 5V batteries Battery Operating Time 120 h without backlight Operating Temperature C 10 50 Storage Temperature C 20 70 Relative Humidity 90 30 C Dimension mm in 125x65x29 4 92x2 56x1 14 Weight g oz 160 5 64 ...

Страница 15: ...e 2 REF Press and hold this key to store current power value as the reference value Quickly press this key to enter the relative measurement mode This mode compares the current power with the reference power and shows the relative power value in dB 3 Measurement Setting Press this key to switch between the absolute measurement dBm and relative measurement nW of the optical power 4 Wavelength Selec...

Страница 16: ...en battery power in use The capacity shown will decrease with battery power Replace batteries as needed 3 Auto off the power meter will automatically shut off when idle for ten minutes Press power button quickly to turn Auto Off function on or off 4 KHz Frequency KHz 0 27 1 00 or 2 00 KHz 5 Power Value dBm nW dB 6 Reference Power Value dbm 1 2 6 5 3 4 ...

Страница 17: ...n the power meter to the light source by pressing For multimode 850nm is recommended For single mode 1310nm is recommended 4 Press to choose the power display unit dBm or nW Set to dBM 5 The power meter will then display the tested power value on the center of the screen Set this as the reference value by pressing and holding for two seconds The screen will then read 0 00dBM Absolute Power Measure...

Страница 18: ... time 1 If the battery level is low turn off the unit immediately and replace the batteries 2 Remove the batteries if light source is not in use for an extended period of time Battery Replacement Troubleshooting Issue Possible Reason Solution Faint screen display No backlight Low battery power Replace the batteries Unit fails to turn on Low battery power or battery inserted incorrectly A Replace t...

Страница 19: ... time during this warranty period we will at our sole discretion replace and repair or refund the purchase price of the product The worth of the repair or replacement will not be higher than purchasing price of this unit 2 If device issues cannot be solved by the troubleshooting methods please contact us or the local distributor directly 3 We will repair or replace the unit free of charge in case ...

Отзывы: