background image

Page 31 of 40

Speed and current curves - 24V motor

The values below are typical values and made with a stable power supply and an ambient temperature of 20˚C.

LA35 - 24V current vs load

0

1

2

3

4

5

6

0

1000

2000

3000

4000

5000

6000

7000

Load (N)

Amper

e

3510xx.

3520xx.

3530xx.

3540xx.

LA35 - 24V speed vs load

0

5

10

15

20

25

0

1000

2000

3000

4000

5000

6000

7000

Load (N)

Speed (mm/s)

3530xx.

3520xx.

3510xx.

3540xx.

Содержание LA35

Страница 1: ...U S E R M A N U A L ACTUATOR LA35 To learn more about LINAK please visit w w w l i n a k c o m...

Страница 2: ...Page 2 of 40...

Страница 3: ...commended fuse 12 Actuator without feedback 13 Actuator with Potential free endstop signal output 14 Relative positioning Single Hall 15 16 Potential free endstop signals and relative positioning Sing...

Страница 4: ...and current curves 30 31 12V motor 30 24V motor 31 Label for LA35 32 Key to symbols 33 LA35 Ordering example 34 Chapter 5 Maintenance 35 Repair 35 Main groups of disposal 35 Warranty 36 Declaration of...

Страница 5: ...eave the factory they undergo full function and quality testing Should you nevertheless experience problems with your LINAK product system you are always welcome to contact your local dealer LINAK sub...

Страница 6: ...will be installed used and operated as each individual application is unique The suitability and functionality of the LINAK product and its performance under varying conditions application vibration l...

Страница 7: ...not use the product products unless they are under surveillance or they have been thoroughly instructed in the use of the apparatus by a person who is responsible for the safety of these persons Moreo...

Страница 8: ...afely If irregularities are observed the actuator must be replaced Recommendations Do not place load on the actuator housing and do prevent impact or blows or any other form of stress to the housing E...

Страница 9: ...do so could shorten the life of the actuator Also avoid applying a skew load on the actuator The actuator can rotate around the pivot point in the front and rear end If this is the case it is of high...

Страница 10: ...uction concerning the turning of the piston rod eye and inner tube When mounting and taking into use it is not permitted to make excessive turns of the piston rod eye In cases where the eye is not pos...

Страница 11: ...e note that if the cables are mounted and dismounted more than 3 times the plugs can be damaged Therefore we recommend that such cables are discarded and replaced Also note that the cables should not...

Страница 12: ...pply for actuators without integrated controller must be monitored externally and cut off in case of current overload Recommended fuse for actuators without integrated controller Type Spindle Pitch mm...

Страница 13: ...r normal conditions 12V max 10A depending on load 24V max 5A depending on load To extend actuator Connect Brown to positive To retract actuator Connect Brown to negative Blue To extend actuator Connec...

Страница 14: ...VDC 12V 20 24V 10 Under normal conditions 12V max 10A depending on load 24V max 5A depending on load To extend actuator Connect Brown to positive To retract actuator Connect Brown to negative Blue To...

Страница 15: ...Page 15 of 40 Actuator with relative positioning Single Hall Connection diagram Fig 3 35xxxxx0Hxxxxxx BROWN BLUE WHITE VIOLET BLACK...

Страница 16: ...power supply 10 28VDC Current consumption Max 40mA also when the actuator is not running Black Signal power supply GND Green Not to be connected Yellow Not to be connected Violet Single Hall output PN...

Страница 17: ...Page 17 of 40 Actuator with potential free endstop signals and relative positioning Single Hall Connection diagram Fig 4 35xxxxx1Hxxxxxx BROWN BLUE YELLOW GREEN RED VIOLET BLACK IN OUT WHITE...

Страница 18: ...positive White Signal power supply 10 28VDC Current consumption Max 40mA also when the actuator is not running Black Signal power supply GND Green Endstop signal out Output voltage min VIN 2V Source c...

Страница 19: ...Page 19 of 40 Actuator with absolute positioning Analogue feedback Connection diagram Fig 5 35xxxxx0xxxxxxx BROWN BLUE WHITE VIOLET BLACK...

Страница 20: ...ive To retract actuator Connect Brown to negative Blue To extend actuator Connect Blue to negative To retract actuator Connect Blue to positive White Signal power supply 10 28VDC Current consumption M...

Страница 21: ...Page 21 of 40 Actuator with potential free endstop signals and absolute positioning Analogue feedback Connection diagram Fig 6 35xxxxx1xxxxxxx BROWN BLUE YELLOW GREEN RED VIOLET BLACK IN OUT WHITE...

Страница 22: ...tor Connect Brown to negative Blue To extend actuator Connect Blue to negative To retract actuator Connect Blue to positive White Signal power supply 10 28VDC Current consumption Max 40mA also when th...

Страница 23: ...Fig 7 35xxxxx2xxxxxxx BROWN BLUE YELLOW GREEN WHITE VIOLET BLACK 12 24V DC RED INWARDS OUTWARDS FEEDBACK SIGNAL OUT M H Bridge IN OUT Hall 0 10V Ready Please be aware that if the power supply is not...

Страница 24: ...current limit 18A 24V current limit 9A Note Do not change the power supply polarity on the brown and blue wires Power supply GND is electrically connected to the housing If the temperature drops belo...

Страница 25: ...pulse 5mm pitch 0 63mm per pulse 9mm pitch 1 13mm per pulse 12mm pitch 1 5mm per pulse Frequency Frequency is 30 125 Hz on Single Hall output depending on load and spindle Overvoltage on the motor can...

Страница 26: ...e damaged Change the cable For IC only Wrongly connected For IC only Please make sure that the power supply polarity is properly connected otherwise you might damage the actuator Check the wire connec...

Страница 27: ...ctuator to fully extended and retracted positions Feedback output overloaded Reduce the load according to your chosen feedback type Actuator runs in smaller steps Insufficient power supply Check the p...

Страница 28: ...lease see the User Manual for SMPS T160 Usage Duty cycle at 6000N and 3mm pitch is max 10 Noise level 48 dB A measuring method DS EN ISO 3743 1 actuator not loaded Safety device regarding functional f...

Страница 29: ...9 116 54 10 2 10 2 Installation dimension 6 1 17 17 6 1 22 26 11 13 153 Stroke 300 200 stroke Stroke 300 250 stroke Minimum Installation dimension 300 mm 83 5 27 27 233 29 116 54 10 2 10 2 Installatio...

Страница 30: ...power supply and an ambient temperature of 20 C LA35 12V current vs load 0 1 2 3 4 5 6 7 8 9 0 1000 2000 3000 4000 5000 6000 7000 Load N Ampere 3510xx 3520xx 3530xx 3540xx LA35 12V speed vs load 0 2...

Страница 31: ...a stable power supply and an ambient temperature of 20 C LA35 24V current vs load 0 1 2 3 4 5 6 0 1000 2000 3000 4000 5000 6000 7000 Load N Ampere 3510xx 3520xx 3530xx 3540xx LA35 24V speed vs load 0...

Страница 32: ...is line also contains a reference to the product s IP protection degree 4 Power Rate 24VDC Max 3 1 Amp Input voltage for the product and maximum current consumption 5 Duty Cycle 10 Max 2 min 18 min Th...

Страница 33: ...all relevant EC directives CE Regulatory Compliance Mark The Australian safety EMC regulations RCM China Pollution control mark also indicates recyclability China RoHS legislation ISO 7000 0434A Cauti...

Страница 34: ...A Modbus Special article number only SAFETY OPTIONS None 1 Safety Nut 2 Splines 3 Splines with safety nut PISTON ROD EYE 1 10 2 hole with slot for 10mm pin AISI 303 2 12 9 hole with slot for 1 2 pin...

Страница 35: ...rs from LINAK are greased with anticorrosive grease or similar Repair Only an authorised LINAK service centre should repair LINAK actuator systems Systems to be repaired under warranty must be sent to...

Страница 36: ...her details please see standard terms of sale and delivery for LINAK A S Note Only an authorised LINAK service centre should repair LINAK actuator systems Systems to be repaired under warranty must be...

Страница 37: ...does also comply with EMC requirements of The Machinery Directive 2006 42 EC The Recreational Craft Directive 94 25 EC The Vehicle EMC Directive 2004 104 EC and the following standards DS EN 13309 20...

Страница 38: ...5 1 Electricity supply The relevant technical documentation is compiled in accordance with part B of Annex VII and that this documentation or part hereof will be transmitted by post or electronically...

Страница 39: ...Page 39 of 40...

Страница 40: ...ile 35 387 634 6554 Republic Of Ireland Mobile E mail sales linak co uk www linak co uk ITALY LINAK Italia S r l Phone 39 02 48 46 33 66 Fax 39 02 48 46 82 52 E mail info linak it www linak it JAPAN L...

Отзывы: