background image

 

www.techfass.com

 

RFID reader 

WREM 81 MTM(VR)

 

10 

4 Wiring diagram 

 
 
 

4.1  Connection possibilities WREM 81 MTM(VR) 

Reader module can be connected as follows: 
 

 

FIGURE A

: Configuration and firmware update. 

To configure the reader or update the firmware, it must connect to the converter, eg APSUSB or APSLAN and use 
the desktop application APS Reader. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  

 

FIGURE B

: Connection WREM 81 MTM(VR) to the wiegand door controller 

 
The Wiegand output of the reader is connected to the Wiegand input of the door controller, eg MWGD 82 or 
MWGD 46. Do not pull the wiegand interface W0, W1 in one twisted pair of UTP cable, use two, one pair for 
each signal. The power supply is in range of 8 -28 Vdc, please use the signal wires for LED and buzzer control if 
needed. These can be connected and controlled by only one wire from MWGD 82. 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

Содержание WREM 81 MTM

Страница 1: ...WREM 81 MTM VR RFID reader 13 56 MHz 125 kHz...

Страница 2: ...ess control b Parameters Input voltage 8 28 Vdc Typical current consumption 53 mA 12 V Maximum input power 1 1 W Reading ID media EM Marin Jablotron 1x RS 485 update firmware wiegand output format set...

Страница 3: ...stem it has its own power supply and bus for receivers WREM 81 MTM VR has its own cabling configuration bus and wiegand interface for door controller or APS mini Plus or APS 400 reader module or third...

Страница 4: ...The reader can be configured via the RS 485 bus using the APSUSB converter and the program APS Reader...

Страница 5: ...2 2 Installation instructions 8 3 RFID reading 9 3 1 Reading at 125 kHz 9 3 2 Wiegand output configuration 9 4 Wiring diagram 10 4 1 Connection possibilities WREM 81 MTM VR 10 5 Settings 12 5 1 Setup...

Страница 6: ...SO card 125 kHz EM Marin 3 5 cm Signalization RGB led Piezo 1 1 pc 1 2 Communication interface INTERFACE DESCRIPTION TECHNOLOGY PROPERTIES Service data bus RS 485 19 200 bit s 8 datov ch bit sud parit...

Страница 7: ...wer supply Vout dc 4 Pink Wiegand data 1 Wiegand input MWGD 82 5 Green Wiegand data 0 Wiegand input MWGD 82 6 Gray Input 2 IN 2 LED control MWGD 82 7 Yellow Input 1 IN 1 buzzer control MWGD 82 8 Brown...

Страница 8: ...y to wiegand interface this bus must be connected in one twisted pair The actual configuration is performed using eg the APSUSB converter and the APS Reader program 2 2 3 Radio signal interferences If...

Страница 9: ...ng 3 1 Reading at 125 kHz The device read media on a frequency of 125 kHz like EM Marin e g EM4200 EM4305 Next example of supported media technology is Jablotron ID 125 kHz settings possibilities Defa...

Страница 10: ...use the desktop application APS Reader FIGURE B Connection WREM 81 MTM VR to the wiegand door controller The Wiegand output of the reader is connected to the Wiegand input of the door controller eg MW...

Страница 11: ...WREM 81 MTM VR to the MTM entry panel you can use your own access control system power supply Connect the wiegand interface power supply minimum and if possible the signal for LED and buzzer control a...

Страница 12: ...techfass com cs produkty 101 produkt 389 aps reader 5 2 Indicative parts RGB LED and buzzer PART ACTION DESCRIPTION Red LED Continuously lit Power supply Green LED Flash ID media reading lock release...

Страница 13: ...its MSB 32 data bits MSB 32 data bits reversed LSB 32 data bits reversed LSB 32 data bits reversed LSB 24 data bits MSB 24 data bits MSB 24 data bits MSB Facility code 0x01 16 data bits MSB Facility c...

Страница 14: ...2 Declaration of conformity The manufacturer TECH FASS ltd declares that the product follows legal requirements and fulfils necessary European directives The declaration of conformity document can be...

Страница 15: ...TECH FASS s r o V t nsk 1611 19 Praha...

Отзывы: