techem HKR Скачать руководство пользователя страница 24

During normal operation, the following are displayed: 
switching periods, operating mode, temperature setting and 
day of the week. 
The bars indicating the weekly program’s switching periods 
are shown for every other time interval. For an example, 
please refer to “2. Weekly program: Examples”. 

 

 

6. Setting the holiday function 

 
If you want a fixed temperature to be maintained for a set period of time while you are on 
holiday or during a party, you can make use of the Holiday function. 

 

Press and release the menu button repeatedly until the suitcase symbol

. appears 

on the display. 

 

Use the setting wheel to set the end of the time period during which the temperature is to 
be maintained. 

 

Press the OK button to confirm. 

 

Then use the setting wheel to set the date. 

 

Press the OK button to confirm. 

 

Use the setting wheel to set the temperature; press OK to 

confirm. The display will flash to confirm your settings. 

The set temperature will remain in force until the specified 
time. After that, the actuator will adopt Auto mode. 
 

7. Comfort and set-back temperatures 

 
The comfort/set-back temperature button

 provides an easy and convenient way of 

switching between these two temperatures. The factory settings are 21.0°C and 17.0°C 
respectively. To adapt them, proceed as follows: 
 

 

Press and hold down the comfort/set-back temperature button

. for more than 3 

seconds. 

 

The sun symbol

 will appear on the display along with the current comfort 

temperature. 

 

Use the setting wheel to modify the temperature; press OK to confirm. 

 

The moon symbol

 will appear together with the setback temperature. 

 

Use the setting wheel to modify the temperature; press OK to confirm. 

 
The temperature can even be modified in Auto mode at any time by using this button. The new 
setting will be retained until the program’s next switching time. 
 

8. Child-proof lock/Operating inhibit 
 

Operation can be inhibited. 

 

To activate/deactivate the operating inhibit, briefly press the Menu and

 buttons at 

the same time.. 

 

Once the function is active, “LOC” will appear on the display. 

 

To deactivate the function, press both buttons again. 

 

9. Setting the heating break 

 

24

Содержание HKR

Страница 1: ...Operating Manual HKR 2 Energy saving controller for radiators HKR p 18 1...

Страница 2: ...I 3 II 4 1 4 2 5 3 6 1 7 2 8 3 9 4 9 5 10 6 10 7 11 8 11 9 12 10 12 11 12 12 13 13 13 14 13 15 14 16 14 17 15 18 15 19 16 2...

Страница 3: ...1 Manu Auto C D 3 E F G H I 3...

Страница 4: ...II 1 2 LR6 1 4...

Страница 5: ...2 INS INS INS 4 INS 3 5...

Страница 6: ...3 Danfoss RA RAV RAVL 18 RAV RA RAV INS ADA 6...

Страница 7: ...INS ADA F1 F2 F3 INS 1 3 7 00 00 23 59 3 PRO DAY 7...

Страница 8: ...0 00 0 00 17 6 00 6 00 0 00 23 59 7 23 59 2 3 7 6 00 9 00 17 00 23 00 00 00 06 00 17 0 06 00 09 00 21 0 09 00 17 00 17 0 17 00 23 00 21 0 23 00 23 59 17 0 0 00 6 00 6 00 9 00 17 00 23 00 8...

Страница 9: ...0 06 00 16 0 06 00 09 00 22 0 09 00 12 00 17 0 12 00 14 00 20 0 14 00 17 30 17 0 17 30 23 30 21 0 23 30 23 59 16 0 00 00 08 30 17 0 08 30 17 00 21 0 17 00 23 59 17 0 00 00 23 59 15 0 3 3 3 Manu Auto 4...

Страница 10: ...PRO 1 DAT POS DST AER TOF RES 65 5 2 6 10...

Страница 11: ...7 21 0 17 0 8 Menu LOC 11...

Страница 12: ...9 Manu ON Manu 10 Manu OFF Manu 11 15 3 AER 0 12...

Страница 13: ...12 3 5 20 18 2 0 3 OF 13 3 RES CFM 14 13...

Страница 14: ...15 F1 F2 F3 12 00 CAL 16 14...

Страница 15: ...18 Heimeier MNG Junkers Landis Gyr Duodyr Honeywell Braukmann Oventrop Schl sser Simplex Valf Sanayii Metrik Maxitrol Watts Wingenroth Wiroflex R B M Tiemme Jaga Danfoss RA Danfoss RAV Danfoss RAVL 1...

Страница 16: ...19 3 100 2 LR6 3 63 66 92 30 1 5 16...

Страница 17: ...17...

Страница 18: ...menu 25 5 Display content during normal operation 26 6 Setting the holiday function 26 7 Comfort and set back temperatures 27 8 Child proof lock Operating inhibit 27 9 Setting the heating break 28 10...

Страница 19: ...program G Current temperature setting time and date indicator menu items functions H button For switching between set back and comfort temperatures I OK button For confirming saving II General functio...

Страница 20: ...mber will be displayed briefly once you have inserted replaced the batteries and then you will be automatically prompted to set the date and time of day Use the setting wheel B to set the year A Confi...

Страница 21: ...y Following installation the actuator will perform an adjustment run so that it can adapt to the valve During this process ADA will be displayed Place the actuator on the valve Tighten the union nut I...

Страница 22: ...y time via the setting wheel The modified temperature will then be retained until the next program changeover 2 Weekly program Examples The energy saving controller allows you to store up to 3 heating...

Страница 23: ...ting wheel Auto Weekly program The temperature is controlled automatically in accordance with the stored weekly program 4 Configuration menu The configuration menu can be used to modify settings To ac...

Страница 24: ...e specified time After that the actuator will adopt Auto mode 7 Comfort and set back temperatures The comfort set back temperature button provides an easy and convenient way of switching between these...

Страница 25: ...c time period factory setting 15 minutes While this function is active the window open symbol appears on the display Press and hold down the menu button for more than 3 seconds Use the setting wheel t...

Страница 26: ...ator fastening F3 Adjusting range too small Check heating valve At 12 00 every Saturday the actuator performs a weekly descaling function to prevent valve calcification CAL will appear on the display...

Страница 27: ...RAV Included in scope of supply Danfoss RAVL Included in scope of supply Other adapters available as accessories 19 Technical properties Supply voltage 3 V Max current consumption 100 mA Batteries 2x...

Отзывы: