12
Displays/operation
It is possible to step through the individual displays by pressing the push-button. In doing
so, a distinction is made between short and long presses of the button.
Briefly
pressing
the button (
< 3
seconds) allows the user to step through the display
within a loop.
With a
long
button press (
> 3
seconds), the display steps through into its next loop.
Error codes
If an error occurs, the error code is shown in the main loop. All the other windows conti-
nue to be available by pressing the button.
Code
Description
C-1
Fundamental parameter in flash memory or RAM destroyed
E-1
Faulty temperature measurement:
- Temperature range outside (-19.9 °C...189,9°C)
- Sensor short circuit
- Sensor break
E-3
Sensors in hot and cold branches switched
E-5
Readout too frequent - optical communication momentarily not possible
E-8
Primary power supply failed (only with mains adapter)
- supply via backup battery
E-9
Warning: Battery capacity is running out
Reading out data/ programming
!
Prerequisites:
Techem Bluetooth optical reading head or Diehl metering Bluetooth optical
reading head.
The IZAR@SET software for reading out and configuring the standard functions
The following can be changed with IZAR @SET software on Techem notebooks:
Due date
5
Due date loop 1.1
m-bus primary address
6
Information loops 3.1 and 4.1
Содержание Classic S3
Страница 74: ...74 250mm Plug Play M Bus max 10m max 10m Pt 500 300mm 1 2 3 O O 4 5 6 7 8 9 45...
Страница 75: ...75 90 2 TH 5 6 TC 7 8 4 1 5 6 2 3 7 8 4 10 open collector 11 Ground 1 2 3 4 5 6...
Страница 81: ...81 250 Plug Play M Bus 10 10 Pt 500 300 1 2 3 4 5 6 7 8 9 RU...
Страница 82: ...82 45 90 2 TH 5 6 TC 7 8 4 1 5 6 2 3 7 8 4 10 11 1 2 3 4 5 6...
Страница 87: ...87 E1 M1 DE 07 MI004 47114711 PT500 PN PS Q K CE M Q Qq C 1 x l S kWh 000...
Страница 136: ...136...
Страница 137: ...137...
Страница 138: ......
Страница 139: ......
Страница 142: ......
Страница 143: ......