IV.e.5) Valve type
By means of this setting, the user selects the type of the controlled
valve between:
CH
- it is set to adjust CH circulation temperature.
FLOOR
- it is set to adjust floor heating circulation temperature. Floor type
protects the installation from dangerous temperatures. If the valve type is set
as CH and it will be connected to floor system, this may result in the
destruction of fragile floor installation.
IV.e
.6
) Room regulator
In this function, the user has the possibility to select the type of room regulator,
which will be assigned to
valve 1
:
➔
TECH regulator
After selecting this type of "room regulator", valve will work according to <
change in
the preset valve temperature>
and <
difference of room temperatures
parameters
(see chapter IV.c.8 and 9). This regulator should be connected to RJ (telephone)
sockets of ST-408 controller by means of a four - core wire ended with the
appropriate plugs (to the socket at the back of the controller).
➔
Standard 1 regulator
After selecting such (two-state) regulator, the valve will work according to <
room
regulator reduction
parameter (see chapter IV.c.10). The connection of such "room
regulator" should be performed to the place described at the controller:
Room
regulator 1
with the use of two-core wire.
➔
Standard 2 regulator
After selecting such (two-state) regulator, the valve will work according to <
room
regulator reduction
parameter. The connection of such "room regulator" should be
made to the place described at the controller:
Room regulator 2
with the use of two-
core wire.
Communication plug for TECH regulator (at the back of the controller)
-
15
-