2/15
Page 11 of 26
Control Inputs
, Euro Style Barrier Strip,
common sensing for Switches, or PLC
Switch Common
Shutoff
(Lowest Priority) - Active low, momentary, or sustained, see below
Disables both Operator and Remote Speakers
(Overridden by “Activate”, “Push to Talk”)
Power on, quiescent state, Operator Shutoff
Activate
- Active Low, momentary, or sustained
Overrides “Shut Off”,
Cancels Call Tone (Jumper Option)
Cause Privacy Tone to be sent (Jumper Option)
Push to Talk (PTT)
- Active Low, momentary or sustained
Forces the Remote speaker on while depressed (Sustained)
Cancels “Call Tone” (Jumper Option)
Activates the Intercom if Inactive
VOX Inhibit
- Active low, sustained
Defeats VOX while depressed,
Provides privacy to the Operator microphone, when using VOX
Call
- Active low, momentary
Causes ‘Call Tone’ to be sent to the Inside speaker
Causes Call Light to flash
Indicator Outputs,
Euro Style Barrier Strip
Open Collector Transistors, Common sensing for Indicators, or PLC V<30Volts, I<200MA
Common
Remote Active, Remote Microphone Keyed
, low when Keyed
Operator Active, Operator Microphone is Keyed
, low when Keyed
Call Indicator
, flashes Low when Call Tone is present
Power
, Euro Style Barrier Strip, connected in parallel with Barrel Connector
+24 Volts, DC
Power Supply Return
Chassis
Barrel Connector
, two in Parallel
PJ-102A, center connector positive
Содержание IC-52B