Important Safety Information

Do not conceal or extend bus bar conductors through a 
building wall.

Do not install this lighting system in a damp or wet location.

To reduce the risk of fire and burns, do not install this 
lighting system where the uninsulated open bus bar 
conductors can be shorted or contact any conductive 
materials.

To reduce the risk of the system overheating and possibly 
causing a fire, make sure all the connections are tight.

Do not install fixture assemblies closer than six inches to 
curtains or similarly combustible materials.

Turn the electrical power off before modifying the lighting 
system in any way.

The fixtures used with the system must be identified to be 
used with the corresponding system.

Minimum volume of the electrical box must be 6 cubic 
inches (98 cubic centimeter).

The system is "ETL" listed for USA and Canada only when all 
the products used are supplied by Tech Lighting.

It is important to wire the remote transformer for the system 
as described in these instructions. 

Load the circuit of the remote transformers to no more than 
the maximum rated capacity as specified. 

SAVE THESE INSTRUCTIONS!

7400 Linder Ave, Skokie, IL 60077

847.410.4400

www.techlighting.com

© 2008 Tech Lighting, L.L.C. All rights reserved. The "Tech Lighting" graphic is 
a registered trademark of Tech Lighting, L.L.C. Tech Lighting reserves the right 
to change specifications for product improvements without notification.

A Generation Brands Company

Содержание 700AT300TR

Страница 1: ...only This product may be dimmed only with a low voltage magnetic dimmer Using a dimmer not designed for low voltage magnetic applications may work initially but will eventually cause transformer failure and will void the warranty The dimmer must be derated as indicated by the dimmer manufacturer This product is intended for use with Tech Lighting low voltage lighting systems only During installati...

Страница 2: ... the primary power line coming into the transformer If the voltage is not in the range of 115 120 volt then pick the proper terminal tap using the Terminal Tap Table to reconnect the second low voltage wire Install drywall NOTE Other wire sizes that comply with electrical code can be used but may result in an increased voltage drop and reduced lamp intensity NOTE The THHN wire sizes are for 3 drop...

Страница 3: ...ER After installing the entire low voltage system if the lamps have low intensity then measure the voltage at the fixture closest to the power feed contacts with a voltmeter The system must be at least 80 loaded and the voltmeter should read between 11V 12V AC If the voltage does not fall in this range call Tech Lighting Technical Support at 847 410 4606 Operate the system for five minutes On the ...

Страница 4: ... way The fixtures used with the system must be identified to be used with the corresponding system Minimum volume of the electrical box must be 6 cubic inches 98 cubic centimeter The system is ETL listed for USA and Canada only when all the products used are supplied by Tech Lighting It is important to wire the remote transformer for the system as described in these instructions Load the circuit o...

Отзывы: