Screen View 

After  clicking  on  the  screen  view  icon  the  user  has  the 
ability  to  set  the  appearance  of  the  main  screen.  By 
default  it is set to the  pre-installed screen, but you  can 
also set the panel screen. 
 
 
 
 

 

Night from hour/Day from hour 

In further sub-menus of the screen menu you can decide which hours the controller will switch to the 
night mode (Night from hour) as well as return to the day mode (Day from hour). 
 

Brightness during the day/brightness at night 

After clicking on the icon, the user may set the percentage value of the screen brightness during the 
day and at night. 
 

VI.d) Weekly Control  

This function allows you to change the set temperature of 
the room in a day-night cycle. 
 

You  can  set  each  day  you  can  set  the  device  to 

change to a specific temperature at any hour on the main 
set value in a 24 hour day-night cycle. 

 

 

 

 

First select the day on which time deviations will 

be set – for this option click on the Settings icon and then 
select the day for which you want to set the temperature. 
 

 
 

 

 

 
 
 

After selecting the day, you will see the panel for 

setting  temperature  deviations  within  selected  time 
intervals. 
 
 

To facilitate this, you can copy the set deviation for 

subsequent hours – just click on the symbol 

 on the 

selected value and by means of the arrows copy selected 
settings for subsequent hours.  

 
 

 

 

 
 
 

Содержание ST-280

Страница 1: ...Tech 1...

Страница 2: ...ration of the Controller 8 IVa Operating Principle 8 IVb Main Screen Description 8 V Controller Functions Menu Options 12 VI a Time 14 VI b Securities 15 VI c Screen 16 VI d Weekly Control 17 VI e Boi...

Страница 3: ...eld liable for damage caused by negligence WARNING Live electrical device Before any activities related to power supply connecting wires device installation etc you must ensure that the regulator is n...

Страница 4: ...n of the regulator and modulation of its parameters An additional advantage is the possibility to load photos to the controller s memory which will be displayed as a screensaver The ST 280 room regula...

Страница 5: ...the relevant qualifications WARNING There is a danger of fatal electrical shock from touching live connections You must disconnect the electrical connection and protect against accidental connection b...

Страница 6: ...uts in accordance with colours of wires The cable is then connected to RJ12 connector which you should plug into the regulator power supply the place of connection is marked on the scheme as point 2 t...

Страница 7: ...ordance with colours of wires This cable is then connected to the RJ12 connector and should be plugged into the v2 module the place of connection is marked on the scheme as point 2 there is an additio...

Страница 8: ...es etc IVb Main Screen Description The controller is equipped with a large touch screen display The main screen displays the current state of basic parameters for the boiler Depending on the user s se...

Страница 9: ...of the valve not being installed the room regulator will display an icon 9 Boiler 1 temperature current and set clicking the screen in this area will switch you to the menu which enables you to introd...

Страница 10: ...on the main controller 6 Current room temperature 7 Current time and date 8 Right parameters panel 9 Buttons allowing change of active view of parameters panel 10 Access to the controller menu 11 Lef...

Страница 11: ...s panel it is possible to change the set temperature of the boiler Valves data panel View of the current temperature and set temperature of valve 1 2 3 or 4 after clicking on this panel it is possible...

Страница 12: ...r after clicking on this panel it is possible to change the pumps operation mode A selection can be made from among the following modes Home heating Priority parallel pumps summer mode with additional...

Страница 13: ...Screen View Panels Screen Installation Screen Night from Hour Day from Hour Brightness During the Day Brightness at Night Weekly control Activated Disabled Settings Boiler Control Submenu Subject to...

Страница 14: ...ser to set the current time according to which the regulator will then operate Date This function allows the user to set the current date according to which the regulator will then operate Alarm clock...

Страница 15: ...ich the alarm clock is to be activated Controller screen view at the time of activation of the alarm clock VI b Securities After clicking on the Securities icon on the main menu you will see the panel...

Страница 16: ...creen Time out after expiration of the set idle time the screen will switch to stand by function Import of Photos Any photos you want to import to the controller s memory must be first prepared by mea...

Страница 17: ...ss during the day and at night VI d Weekly Control This function allows you to change the set temperature of the room in a day night cycle You can set each day you can set the device to change to a sp...

Страница 18: ...ller between Home heating Priority parallel pumps summer mode More detailed descriptions of these operating modes can be found in the operation manual for the boiler controller Submenu for the pellet...

Страница 19: ...de the room and in accordance with the schedule of the boilers daily operations The current temperature inside the room is the priority for boiler under operation in this mode if the temperature in th...

Страница 20: ...for changing the language for the user VI g Information about the Operating Program By clicking on this icon the display will show the boiler manufacturer s logo along with the software version VI h...

Страница 21: ...selection is made the Boiler control submenu will be changed I Alarms The ST 280 room temperature regulator will signal all alarms generated by the main controller When the alarm activates the room re...

Страница 22: ...g provisions of Low Voltage Directive LVD 2006 95 EC the Act of 13th April 2007 on Electromagnetic Compatibility Official Journal 07 82 556 implementing provisions of Directive EMC 2004 108 EC and the...

Страница 23: ...y received a registry number assigned by the Chief Inspector of Environmental Protection The symbol of a crossed out disposal bin on the product means that the product must not be thrown out to genera...

Страница 24: ...ST 280 user s manual 24...

Отзывы: