background image

EU-297  

 

15 

 

1.7.

 

FLOOR HEATING ON/OFF 

This function is used to enable (ON) or disable (OFF) the underfloor heating, with the 
use of  

  

.   

When the underfloor heating is enabled ( 

), the user may configure the following 

parameters: 

 

Maximum temperature  -  in order to set  the maximum floor temperature,   
press MENU until the floor heating icon appears on the  screen. Next, use   

 or 

 to enable the heating, and then use the same buttons to set the 

maximum temperature.  

 

Minimum temperature - in order to set the minimum floor temperature, press MENU until the floor heating icon 
appears on the screen. Next, use   

 or 

 to enable the heating, and then use the same buttons to set the 

minimum temperature. 

 

 

Hysteresis - underfloor heating hysteresis defines the tolerance for the maximum and minimum temperature. 
The settings range is from  0,2°C to 5 °C. 
 
If the floor temperature exceeds the maximum temperature, the underfloor heating will be disabled. It will be 
enabled only after the temperature has dropped below the maximum floor temperature minus the hysteresis 
value.  
 
Example:  
Maximum floor temperature - 33°C 
Hysteresis- 2°C 
When the floor temperature reaches  33°C, the underfloor heating will be 
disabled. It will be activated again when the temperature drops to  31°C. 
If  the  floor  temperature  drops  below  the  minimum  temperature,  the 
underfloor  heating  will  be  enabled.  It  will  be  disabled    after  the  floor 
temperature has reached the minimum value plus  the hysteresis value.  
 
Example: 
 
Minimum floor temperature - 23°C 
Hysteresis - 2°C 
When the floor temperature drops to 23°C, the underfloor heating will be enabled. It will be disabled when the 
temperature reaches 25°C. 
 
 
 

Содержание EU-297 v2

Страница 1: ...EU 297 v2...

Страница 2: ...VII Device description 11 1 Main screen description 12 VIII Controller functions 13 1 Block diagram main menu 13 1 1 Clock 13 1 2 Pre set day temperature 13 1 3 Day from 14 1 4 Pre set night temperatu...

Страница 3: ...ce etc The device should be installed by a qualified electrician The regulator should not be operated by children WARNING The device may be damaged if struck by a lightning Make sure the plug is disco...

Страница 4: ...e pre set value The EU 297v2 controller functions Maintaining pre set room temperature Manual mode Day night mode Control of the floor sensor Possibility of pairing with the EU MW 3 module Controller...

Страница 5: ...ver included in the controller set mounted near the heating device Hardware versions 1 EU 297 v2 RB EU 297 v2 RBN wireless version powered with two AAA 1 5V batteries 2 EU 297 Z v2 RZ EU 297 v2 RZN wi...

Страница 6: ...two wire communication cable should be connected to the appropriate connectors on the receiver The EU 297v2 room regulator may be used as a wall mountable panel In order to mount it place the rear pa...

Страница 7: ...ng device with a two core cable The cable connection of both devices is shown in the diagram below NOTE The regulator is powered with batteries it is recommended to check the batteries from time to ti...

Страница 8: ...F THE REGULATOR POWER SUPPLY 230V The room regulator may be used as a wall mountable panel In order to mount it place the rear part of the controller in the mounting box on the wall insert the regulat...

Страница 9: ...EU 297 9 The room regulator should be connected to the heating device with a two core cable The cable connection of both devices is shown in the diagram below heating device heating device...

Страница 10: ...erature fails to reach the pre set value the heating device is switched on NOTE In case of no communication e g due to discharged battery the receiver automatically disables the heating device after 1...

Страница 11: ...y The user may set different temperature values for the daytime and nighttime as well as define the exact time of entering day mode and night mode In order to activate this mode press MENU button unti...

Страница 12: ...ton to enable manual mode or to set calibration Press the MENU button to move on to edit next parameters 1 MAIN SCREEN DESCRIPTION 1 Battery level battery version 2 Maximum minimum floor temperature t...

Страница 13: ...AGRAM MAIN MENU 1 1 CLOCK In order to set the time press MENU button until the clock settings appear on the screen The settings concern the flashing parameter Use or to set the hour Next press MENU to...

Страница 14: ...to define the exact time of entering the night mode To configure this parameter press MENU until a flashing icon appear on the screen Use or to set the time of night mode activation 1 6 HYSTERESIS Roo...

Страница 15: ...es the tolerance for the maximum and minimum temperature The settings range is from 0 2 C to 5 C If the floor temperature exceeds the maximum temperature the underfloor heating will be disabled It wil...

Страница 16: ...sensor differs from the actual temperature Calibration setting range is from 9 9 to 9 9 C with the accuracy of 0 1 C To calibrate the built in sensor press the MENU button until the temperature senso...

Страница 17: ...y button on the panel or click the registration button Pressing the registration button again will allow pairing Once registration has been activated in EU MW 3 it is necessary to press the registrati...

Страница 18: ...y 2xAAA 1 5V batteries Measurement error 0 5o C Operation frequency 868MHz EU 297Z v2 Temperature adjustment range 5o C 35o C Power supply 230V 10 50Hz Max power consumption 0 1W Measurement error 0 5...

Страница 19: ...the use of certain hazardous substances in electrical and electronic equipment implementing provisions of Directive EU 2017 2102 of the European Parliament and of the Council of 15 November 2017 amend...

Страница 20: ...TECH 20...

Отзывы: