FIRST START-UP 

In order for the EU-292n v3 controller to operate correctly, follow these steps when starting the device for the first time:  

1.

 

Insert the batteries - in order to do it, remove the controller back cover. 

2.

 

If the room regulator is to control the floor heating system, connect an additional sensor to the floor sensor 

 

connector.  

3.

 

Connect the regulator with the heating device using a two-core cable. 

 

V.

 

HOW TO USE THE CONTROLLER 

1.

 

PRINCIPLE OF OPERATION  

The  EU-292n  v3    room  regulator  is  designed  to  maintain  the  pre-set  room  temperature  by  sending  a  signal  to  the 
heating/cooling device (contact opening) when the pre- set room temperature has been reached. After receiving such a 
signal, the heating/cooling device is disabled (if it is connected to a CH boiler controller, the CH boiler switches to sustain 
mode after receiving the signal). 

If the regulator is used in heating mode, it may also cooperate with a floor sensor. In such a situation, the contact remains 
closed when the floor temperature is below the minimum threshold. After the threshold temperature has been exceeded, 
the contact remains closed until the pre-set room temperature is reached. If the floor sensor temperature exceeds the 
maximum value, the controller will open the contact regardless of the current room temperature.  

 

NOTE 

In order for the floor heating functions to be available in  the controller  menu, an additional sensor  must  be 

connected to the floor sensor contact.  
 

2.

 

OPERATION MODES 

The room regulator may operate in one of the following operation modes:  

 

Day/night mode 

In  this  mode  the  pre-set  temperature  value  depends  on  the  current  time  of  the  day.  The  user  may  set  different 
temperature values for the daytime and nighttime (comfort temperature and economical temperature) as well as define 
the exact time of entering day mode and night mode.   

In order to activate this mode, press EXIT button until day/night mode icon appears on the main screen.  

day/night mode icon 

Содержание EU-292n v3

Страница 1: ...EU 292n User manual 1 EU 292n v3...

Страница 2: ...f the week 11 4 3 Clock settings 12 4 4 Day from 12 4 5 Night from 12 4 6 Button lock 12 4 7 Optimum start 12 4 8 Automatic manual mode 13 4 9 Weekly control 13 4 10 Pre set comfort temperature 15 4 1...

Страница 3: ...es installing the device etc The device should be installed by a qualified electrician The device should not be operated by children WARNING The device may be damaged if struck by a lightning Make sur...

Страница 4: ...ables the regulator to fulfil a wide range of functions maintaining the pre set room temperature manual mode day night program weekly control underfloor heating system control optional an additional t...

Страница 5: ...n diagram The room regulator should be connected with the heating device with the use of a two core cable When connecting devices with a power greater than 1A it is necessary to use a contactor Option...

Страница 6: ...n heating mode it may also cooperate with a floor sensor In such a situation the contact remains closed when the floor temperature is below the minimum threshold After the threshold temperature has be...

Страница 7: ...rol icon appears on the main screen Manual mode In this mode the pre set temperature is adjusted manually from the main screen view with the use of these buttons Manual mode is activated automatically...

Страница 8: ...en view press this button to activate the weekly control or day night mode In the controller menu use this button to confirm the settings and return to the main screen view 3 in the main screen view p...

Страница 9: ...nu 5 Floor temperature 6 Pre set room temperature 7 Time 8 Buttery level 9 An icon informing about room cooling heating The animation differs depending on the selected operation mode Heating mode the...

Страница 10: ...S The user navigates the menu structure using EXIT and MENU In order to edit particular parameters press MENU Next press MENU to view the controller functions the edited parameter is flashing whereas...

Страница 11: ...or until the current day of the week is displayed Press MENU to confirm and move on to the next parameter or press EXIT to confirm and return to the main screen view Menu Day of the week Clock setting...

Страница 12: ...user to define the exact time of entering the night mode When Day night mode is active economical temperature applies at nighttime To configure this parameter press MENU until Night from setting appe...

Страница 13: ...med change resulting from the previous operation mode is introduced If the function is disabled OFF the manual mode remains active regardless of the pre programmed changes 4 9 WEEKLY CONTROL This func...

Страница 14: ...the user opens up the program editing screen Each time the user holds the MENU button the program number changes When the desired number appears on the screen the user may start editing its parameters...

Страница 15: ...15 21 comfort temperature 22 23 economical temperature NOTE When the user finishes the editing process by pressing EXIT button the controller returns to the main screen view and this program is select...

Страница 16: ...lator has been used for a long time if the room temperature measured by the internal sensor differs from the actual temperature Calibration setting range is from 10 to 10 C with the accuracy of 0 1 C...

Страница 17: ...e set temperature tolerance in order to prevent undesired oscillation in case of small temperature fluctuation within the range of 0 2 4 C In order to set the hysteresis press MENU until the hysteresi...

Страница 18: ...confirm and go on to edit the next parameter or press EXIT to confirm and return to the main screen view Optimum start calibration Optimum start calibration starts when the controller detects the heat...

Страница 19: ...ting to electromagnetic compatibility EU OJ L 96 of 29 03 2014 p 79 Directive 2009 125 EC establishing a framework for the setting of ecodesign requirements for energy related products as well as the...

Страница 20: ...TECH 20...

Отзывы: