Declaration of conformity

 

 

Hereby, we declare under our sole responsibility that EU-292n v3 manufactured by TECH STEROWNIKI, head-quartered in 
Wieprz Biała Droga 31, 34-122 Wieprz, is compliant with Directive 2014/35/EU of the European Parliament and of the 
Council of 26 February 2014 on the harmonisation of the laws of Member States relating to the making available on the 
market of electrical equipment designed for use within certain voltage limits
 (EU OJ L 96, of 29.03.2014, p. 357), Directive 
2014/30/EU  
of the European Parliament  and of the Council of 26 February 2014 on the harmonisation of the laws of 
Member  States  relating  to  electromagnetic  compatibility  (EU  OJ  L  96  of  29.03.2014,  p.79),  Directive  2009/125/EC 
establishing a framework for the setting of ecodesign requirements for energy-related products as well as the regulation 
by the MINISTRY OF ENTREPRENEURSHIP AND TECHNOLOGY of 24 June 2019 amending the regulation concerning the 
essential requirements as regards the restriction of the use of certain hazardous substances in electrical and electronic 
equipment, implementing provisions of Directive (EU) 2017/2102 of the European Parliament and of the Council of 15 
November 2017 amending Directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical 
and electronic equipment (OJ L 305, 21.11.2017, p. 8). 

 

For compliance assessment, harmonized standards were used: 

 PN-EN IEC 60730-2-9:2019-06, PN-EN 60730-1:2016-10. 
 
 
 
Wieprz, 11.10.2022 
 
 
 
 
 
 
 
 

 

Содержание EU-292n v3

Страница 1: ...EU 292n User manual 1 EU 292n v3...

Страница 2: ...f the week 11 4 3 Clock settings 12 4 4 Day from 12 4 5 Night from 12 4 6 Button lock 12 4 7 Optimum start 12 4 8 Automatic manual mode 13 4 9 Weekly control 13 4 10 Pre set comfort temperature 15 4 1...

Страница 3: ...es installing the device etc The device should be installed by a qualified electrician The device should not be operated by children WARNING The device may be damaged if struck by a lightning Make sur...

Страница 4: ...ables the regulator to fulfil a wide range of functions maintaining the pre set room temperature manual mode day night program weekly control underfloor heating system control optional an additional t...

Страница 5: ...n diagram The room regulator should be connected with the heating device with the use of a two core cable When connecting devices with a power greater than 1A it is necessary to use a contactor Option...

Страница 6: ...n heating mode it may also cooperate with a floor sensor In such a situation the contact remains closed when the floor temperature is below the minimum threshold After the threshold temperature has be...

Страница 7: ...rol icon appears on the main screen Manual mode In this mode the pre set temperature is adjusted manually from the main screen view with the use of these buttons Manual mode is activated automatically...

Страница 8: ...en view press this button to activate the weekly control or day night mode In the controller menu use this button to confirm the settings and return to the main screen view 3 in the main screen view p...

Страница 9: ...nu 5 Floor temperature 6 Pre set room temperature 7 Time 8 Buttery level 9 An icon informing about room cooling heating The animation differs depending on the selected operation mode Heating mode the...

Страница 10: ...S The user navigates the menu structure using EXIT and MENU In order to edit particular parameters press MENU Next press MENU to view the controller functions the edited parameter is flashing whereas...

Страница 11: ...or until the current day of the week is displayed Press MENU to confirm and move on to the next parameter or press EXIT to confirm and return to the main screen view Menu Day of the week Clock setting...

Страница 12: ...user to define the exact time of entering the night mode When Day night mode is active economical temperature applies at nighttime To configure this parameter press MENU until Night from setting appe...

Страница 13: ...med change resulting from the previous operation mode is introduced If the function is disabled OFF the manual mode remains active regardless of the pre programmed changes 4 9 WEEKLY CONTROL This func...

Страница 14: ...the user opens up the program editing screen Each time the user holds the MENU button the program number changes When the desired number appears on the screen the user may start editing its parameters...

Страница 15: ...15 21 comfort temperature 22 23 economical temperature NOTE When the user finishes the editing process by pressing EXIT button the controller returns to the main screen view and this program is select...

Страница 16: ...lator has been used for a long time if the room temperature measured by the internal sensor differs from the actual temperature Calibration setting range is from 10 to 10 C with the accuracy of 0 1 C...

Страница 17: ...e set temperature tolerance in order to prevent undesired oscillation in case of small temperature fluctuation within the range of 0 2 4 C In order to set the hysteresis press MENU until the hysteresi...

Страница 18: ...confirm and go on to edit the next parameter or press EXIT to confirm and return to the main screen view Optimum start calibration Optimum start calibration starts when the controller detects the heat...

Страница 19: ...ting to electromagnetic compatibility EU OJ L 96 of 29 03 2014 p 79 Directive 2009 125 EC establishing a framework for the setting of ecodesign requirements for energy related products as well as the...

Страница 20: ...TECH 20...

Отзывы: