EU-292 User’s manual
9
IV.
Receiver for wireless controller
EU-292v2 regulator communicates with the heating device (or the CH boiler controller) via radio
signal sent to the receiver. The receiver is connected to the heating device (or CH boiler controller)
via a two-core cable whereas the communication with the room regulator is performed wirelessly
via radio signal.
The receiver has the following control lights:
• green 1 (1)– indicates data reception, goes on during
channel change;
• red (2)– indicates receiver operation;
• green 2 (3) – goes on when the room temperature fails
to reach the pre-set value – the heating device is switched
on.
NOTE
In case of communication failure (e.g. when
the battery is flat), the receiver automatically
disconnects the heating device after 15
minutes.
How to change the communication channel
Channel “35” is the default communication channel in the room regulator. The channel may be
easily changed (if the current channel is used by other devices). To change the channel, press
and hold the channel change button (4) for about 10 seconds until the green control light (1) goes
on. Next, change the communication channel in the room regulator following the procedure
described in part VII.c.7. Confirm with the channel change button. The green light on the receiver
should go off.
Heating
device
Green (1)
Red (2)
Green (3)
Channel
change button