background image

EU-292 User’s manual 

 

17 

 

*Functions  available  in  the  menu  after  the  floor  sensor  has  been  activated  by  connecting  the 
additional sensor to the floor sensor contact and selecting ON in Floor sensor submenu.  
 
 

VII.c.2) Day of the week 

After entering the main menu, all icons which are 
not connected with the parameter which is being 
edited  are  not  displayed.  The  first  parameter  is 
day of the week.   
Press 

 or  

 until the current day of the week 

is displayed. Press MENU to confirm and move on 
to  the  next  parameter  or  press  EXIT  to  confirm 
and return to the main screen view. 
 
 
 

VII.c.3) Time settings 

In  order  to  set  current  time,  press  MENU  until 
time setting panel is displayed on the screen.  
By pressing 

 or  

 set the hour and minutes. 

Press MENU to confirm and move on to the next 
parameter or press EXIT to confirm and return to 
the main screen view. 
 
 
 
 

VII.c.4) Day from… 

This function enables the user to define the exact 
time of entering the day mode. When Day/night 
mode  is  active,  comfort  temperature  applies  at 
daytime. 
To configure this parameter press MENU until Day 
from…
 setting appears on the screen.  
By pressing 

 or  

 set the hour and minute of 

day mode activation.   
Press MENU to confirm and move on to the next 
parameter  or  EXIT  to  confirm  and  return  to  the 
main screen view 
 

VII.c.5) Night from… 

This function enables the user to define the exact 
time of entering the night mode. When Day/night 
mode  is  active,  economical  temperature  applies 
at nighttime. 
To  configure  this  parameter  press  MENU  until 
Night from… setting appears on the screen.  
By pressing 

 or  

 set the hour and minute of 

night mode activation.   
Press MENU to confirm and move on to the next 
parameter or press EXIT to confirm and return to 
the main screen view. 
 
 
 

Содержание EU-292 v2

Страница 1: ...EU 292 User s manual 1 EU 292 v2 v3...

Страница 2: ...TECH 2...

Страница 3: ...VII c Controller functions 16 V c 1 Block diagram main menu 16 VII c 2 Day of the week 17 VII c 3 Time settings 17 VII c 4 Day from 17 VII c 5 Night from 17 VII c 6 Optimum start 18 VII c 7 Service me...

Страница 4: ...WARNING The device should be installed by a qualified electrician The regulator should not be operated by children WARNING Any use other than specified by the manufacturer is forbidden Before and dur...

Страница 5: ...he regulator to fulfil a wide range of functions maintaining the pre set room temperature manual mode day night program weekly control control of the underfloor heating system optional an additional t...

Страница 6: ...TECH 6 III Installation The controller should be installed by a qualified person The diagrams below show an example of connecting the regulator to the controller and heating device...

Страница 7: ...ere III a Connection diagrams 3 versions The room regulator should be connected to the heating device via a two core cable When connecting devices with over 1A load it is necessary to use a contactor...

Страница 8: ...munication cable must be connected to appropriate sockets in the receiver Connection diagrams EU 292v2 In the case of wireless connection use the diagram below the two core communication cable must be...

Страница 9: ...h the pre set value the heating device is switched on NOTE In case of communication failure e g when the battery is flat the receiver automatically disconnects the heating device after 15 minutes How...

Страница 10: ...s 0 9 set 0 as the first digit Example 1 28 is the desired communication channel In order to select this channel set the first digit 2 and the second digit 8 Press and hold the channel change button t...

Страница 11: ...one zone the external controller will not work properly VII How to use the controller VII a Principle of operation The main task of EU 292 room regulator is to maintain the pre set temperature of the...

Страница 12: ...y of the week separately The display shows the hours when the comfort temperature applies In the remaining time period economical temperature applies In order to activate this mode press and hold EXIT...

Страница 13: ...or the other way round or when the user presses EXIT button Example 2 manual mode activation in weekly control mode When weekly control is active the user changes the pre set temperature by pressing...

Страница 14: ...pressing this button in the main screen view activates manual mode and decreases the pre set temperature After entering the menu this button is used to adjust parameters enter the service code etc 4 P...

Страница 15: ...re sensor 8 Icon which indicates displaying current floor temperature no 9 on the display it is necessary to connect the floor sensor and activate it in the controller menu 9 External temperature alte...

Страница 16: ...s the edited parameter is flashing whereas the remaining parameters are not displayed Use or to change the parameter settings Press MENU to confirm the changes and move on to edit the next parameter o...

Страница 17: ...to the next parameter or press EXIT to confirm and return to the main screen view VII c 4 Day from This function enables the user to define the exact time of entering the day mode When Day night mode...

Страница 18: ...al temperature to comfort temperature Activating this function means that at the time of pre programmed change of the pre set temperature from comfort to economical or the other way round the current...

Страница 19: ...communication channel in all devices The channel should be changed only if the current channel is used by other devices In order to change go to service menu and press MENU until the channel change p...

Страница 20: ...ing MENU button the user opens the program editing panel Each time the user holds the MENU button the program number changes When the desired number appears on the screen the user may start editing it...

Страница 21: ...ser finishes the editing process by pressing EXIT button the controller returns to the main screen view and this program is selected as the current program VII c 9 Floor sensor NOTE This parameter is...

Страница 22: ...1 Floor temperature hysteresis Floor temperature hysteresis defines the floor temperature tolerance in order to prevent undesired oscillation in case of small temperature fluctuation within the range...

Страница 23: ...essary to activate the floor sensor beforehand by selecting ON Use or to select desired temperature value Press MENU to confirm and move on to edit the next parameter or press MENU to confirm and retu...

Страница 24: ...r a long time if the room temperature measured by the internal sensor differs from the actual temperature Calibration setting range is from 10 C to 10 C with the accuracy of 0 1 C Press MENU until the...

Страница 25: ...ating to electromagnetic compatibility EU OJ L 96 of 29 03 2014 p 79 Directive 2009 125 EC establishing a framework for the setting of ecodesign requirements for energy related products as well as the...

Страница 26: ...the essential requirements as regards the restriction of the use of certain hazardous substances in electrical and electronic equipment implementing provisions of Directive EU 2017 2102 of the Europe...

Страница 27: ...EU 292 User s manual 27...

Страница 28: ...TECH 28...

Отзывы: