Operator's guide
5. CLEANING OF THE INTERNAL GLASS PANELS
1.
2
External cleaning
1
6. CONNECTION TO MAINS
1
4
5
MAKE SURE THAT: 1
9. REPLACEMENT OF INTERNALIGHT
1
2
3
4
5
(NO LED) 6
7
10. REPLACEMENT OF THE DOOR MAGNETIC GASKET
1
2.
3
Only clean the internal component and glass panels with a soft,wet sponge and a neutral detergent.
. Dry with care using a soft cloth
.For the glass panels use the same products as used for the internal cleaning.
.
.
.
. T
.
. Switch off electricity supply. . Unscrew the screws fixing the upper light holder. . Detach the
fluorescent tube from the upper lamp holder. . Remove the tube from the lower lamp holder. . Remove
the transparent protective tube
. . Replace the fluorescent tube. . Replace everything in
reverse order
.Open the door.
Take hold of the magnetic gasket with your hands and remove it from the frame.
. Insert the new gasket and press all around it when in place
2
A
2.
3
Notice:
7. CONTROLS
1. Refrigeration switch
2. Light switch
3. Rotation switch:
6. Thermometer
Thermostat
a)
4
“
SET or P
”
5
“
UP
”
7
“
DOWN
”
8. CHECKING THE CORRECT FUNCTIONING
2
3
4
5
6
7
8
9.
11. INTERNAL CLEANING (EVERY 15 DAYS)
GBT / GBT VU 1
2.
3.
4
5.
6
7
8
R and G1 1.
2.
3.
. Remove the
protection tape from the steel panel and from the grids.
Ensure that mains voltage and frequency are the same as those stated on the rating plate ( ) attached
to the appliance.
Ensure that the supply socket has the following characteristics:
-
-
. Ensure that there is no danger of explosion (AD) in the room.
The connecting cable to the appliance is H05 VVF, designed for internal use only.
in case the
appliance, during the trasport or storage, has been erroneously placed in horizontal position or upside-
down, it must be left in the correct position for at least 3 hours before connecting it to the electrical supply.
Insert the plug (do not use triple and reduction outlets) (see picture 5).
The controls of the appliance are situated at the front inside a protected recess.
for turning on the refrigeration system.
for turning on the light inside the appliance.
it sets the rotary shelves into motion.
for reading the temperature in
the appliance.
for adjusting temperature in the appliance.
Press key
once to
display the temperature set-point,which can be changed by pressing key
or
(see fig. 6)
he plug is connected
. Refrigeration unit switch is on (green light lit up). . The
thermometer shows the desired temperature for the foodstuffs to be stored in. . Internal light and
rotation switches are on. . The door is closed. . The appliance is not exposed to the direct light of the
sun or to high powered lamps. . The room temperature does not exceed that in which the appliance is
designed to work normally, i.e. +30° C 55% r.h. (Climatic class 4). . The compressor ventilation grilles
are free from obstruction for at least 30 cm.
The foodstuffs are placed on the shelves in the right way
(Max 6 kgs for each shelf), in order to ensure a good circulation of the cool air, especially between the
rear glass panel and the shelves, where the air outlets are.
(see picture 7).
(see picture 8).
. Switch off the appliance.
Open the door and remove the refrigerated goods.
Remove the goods and put them in a suitably refrigerated place. . Remove the bottom cap, that you
will inside of the appliance.
Remove excess water from the drainage outlet by means of the drainage
pipe, which can be accessed by removing the left hand grill. Allow the pipe to drip in a suitable external
container. . Do not use sharp or pointed metal objects to remove ice from the evaporator. . Dry all parts
with care. . Leave the appliance to dry with the door open before restarting.
Switch off the
appliance.
Open the door and remove the refrigerated goods.
Wipe the internal surfaces of the
appliance with a sponge dipped in water with a little sodium bicarbonate. Dry with care (see fig. 9).
a)
b)
c)
It is properly
earthed.
It is appropriate for the nominal current as set out on the rating plate. It complies with the IEC
regulations: Magneto-thermic differential switch with In = nominal value as stated on the rating plate;
Differential with Id sensitivity = 30 mA.