TECALEMIT HORNET W 85 H INOX Скачать руководство пользователя страница 13

44 1672 103-E     

HORNET W 85 H INOX 

13 

5.

 

Automatic pump nozzle A2003-ES 

5.1.

 

Technical Deskription 

5.1.1.

 

General Description 

The automatic pump nozzle A2003-ES in an automatically-closing full hose nozzle for 
the dispensing of fluids listed under no. 2.2 The A2003-ES automatic nozzle have 
been tested in accordance with the DIN EN 13012 standard. 
The standard features of the nozzle include: a safety switching-off and a covering 
that protects against wear and cold conditions. 
The type A2003-ES nozzle is made of stainless steel with an outlet diameter of 3/4” 
(19mm) 

5.1.2.

 

Appropriate use 

The automatic nozzle is state of the art manufactured and is failsafe. 

However hazards can arise from this product if it is not used according to 
specifications. 

Each person concerned with the assembly, commissioning, maintenance and 
operation of the automatic nozzle must have read and understood the entire manual. 

The automatic nozzle of type A2003-ES is only to be used for dispensing aqueous 
urea AUS32 as per ISO 22241 (DEF)!  

Using the machine for any other purpose would constitute inappropriate use. The 
manufacturer shall not be liable for any resultant losses or damages; the risk shall be 
borne by the operating company alone in such cases. 

Adherence to the assembly, commissioning, operating and maintenance conditions 
prescribed by the manufacturer also qualifies as proper use. 

The automatic nozzle may only be used on dispensing installations with motor driven 
pumps. The volumetric flow of the delivery pump may not exceed 10.5 gpm  (40 
l/min) or fall below 

3.1 gpm (12 l/min)

.  

The zero delivery inlet pressure must not exceed 50 psi (3.5 bar). The minimum 
operating pressure is 10 psi (0.7 bar). The local safety and accident prevention 
regulations apply to the operation of the automatic nozzles. 

 

 

Содержание HORNET W 85 H INOX

Страница 1: ...Operating manual HORNET W 85 H INOX Item Number US108 601 200 US108 600 200 US108 600 300 US108 601 400 US108 600 400 US108 600 600 US108 601 201 US108 601 401...

Страница 2: ...mages to the device caused by insufficient knowledge of the operation manual Tecalemit inc All rights reserved Text graphics and layout copyright protected Reproduction and copying including in part o...

Страница 3: ...Running 12 4 2 Tank Procedure 12 4 3 Meter FMT II or FMT 3 optional 12 5 Automatic pump nozzle A2003 ES 13 5 1 Technical Deskription 13 5 1 1 General Description 13 5 1 2 Appropriate use 13 5 1 3 Fun...

Страница 4: ...on or comprehensive material damages Designated Use This device may only be used when functioning free of technical problems and must used according to its designated use with full knowledge of the sa...

Страница 5: ...n cause injuries and fires Note the safety guidelines valid for the product when dealing with oils greases and other chemical substances Maintenance and Repairs In accordance with the legal regulation...

Страница 6: ...ve 131 F 55 C hazard class A III may not be pumped if they have been heated above their flame point The pump has no safety device to prevent automatic restarting after interruption of the power supply...

Страница 7: ...Motor AC Motor Output 780 W Rated Current 9 5 A Voltage 120 V 60 Hz Duty Cycle 100 Protection Class IP 54 Pump Type Hybrid Pump Pump Volume max 12 5 gpm Conveyance Pressure max 36 psi 2 5 bar Suction...

Страница 8: ...E HORNET W 85 H INOX 3 Assembly Instructions The W 85 H INOX is delivered in the following equipment variants Pump with IBC console Drum transfer pump Pump without accessories Optional flow meter FMT...

Страница 9: ...ction tube 1 to the suction side Only tighten the suction tube hand tight 4 Guide the clamping nut 2 onto the suction tube 5 Attach the pressure hose 7 to the hose nozzle 6 an tighten the hose clamp 6...

Страница 10: ...and suspend the nozzle in the holder 3 Position the console 1 of the cover plate of the IBC so that the console is resting on the side 4 Hook the belt 2 on the opposite side 5 Now a suitable coupling...

Страница 11: ...will be decreased in the event of reduced cooling 3 5 Temperature The pump may be operated at environmental temperatures from 14 to 104 F 10 C to 40 C and media temperatures from 20 to 104 F 7 C to 4...

Страница 12: ...immediately and the problem must be remedied The pump has thermal dry running protection which automatically turns off the pump The pump must be turned off after triggering the thermal dry running det...

Страница 13: ...missioning maintenance and operation of the automatic nozzle must have read and understood the entire manual The automatic nozzle of type A2003 ES is only to be used for dispensing aqueous urea AUS32...

Страница 14: ...void damage do not overtighten the screwed connections Do not use Telefon sealing tape 4 After completing the installation vent the pump nozzle and check the connections under pressure for leaks Check...

Страница 15: ...accordingly If small amount are subsequently filled manually and when filling with the control lever locked the volume flow may be less than the minimum allowed In this case the automatic shutdown of...

Страница 16: ...capacity is too low Air is also being sucked in the flow meter is clearly showing more than the dispensed quantity The suction hose has a leakage and the sucked air is also counted Reseal the suction...

Страница 17: ...012 Drip tube 50 1 814 988 019 Tap hose including Hose clamp Anti kink spring Hose shell 60 1 252 711 020 Tap valve urea without catch without rotatable fittings incl WHG 70 1 252 711 021 Tap valve u...

Страница 18: ...t the bottom of the pump chamber 2 Remove the suction housing 2 and replace the rotor 3 3 Always replace the O ring 4 when replacing the rotor 4 After properly positioning the rotor and replacing the...

Страница 19: ...o be followed 9 1 Return of batteries Batteries must not be disposed of with the domestic waste Batteries can be returned free of charge via a suitable collecting point or to the dispatch stores Consu...

Страница 20: ...20 44 1672 103 E HORNET W 85 H INOX TECALEMIT Inc 6324 Greens Road Humble Texas 77396 T 281 446 7300 F 281 619 5613 sales tecalemitusa com www tecalemitusa com...