14
44 1705 001GB-H
FMT 3 meter
3.4
Instructions for retrofitting FMT 3 to HORNET 50 II, 80, 120
•
Before installation, check all components to ensure that all packaging materials have been
completely removed.
•
Remove dispensation hose (1) from 90° elbow (2).
•
Unscrew G1" elbow (2) from the pump (3) (warm it up at the ends, e.g. with a heat gun)
•
Insert the two provided sealing rings all the way into the screw threads of the extension piece
and the swivel joint (4).
•
Screw the provided extension piece (4) to the meter.
•
Screw the meter with extension piece into the pump, simultaneously sealing the joint with pipe
thread sealant or teflon tape. You do not have to pay attention to the direction of flow, as the
FMT 3 can be used with both flow directions.
•
Screw the swivel joint to the meter, which in turn is screwed to the provided G1" elbow (6).
•
Attach dispensation hose (5) to elbow (6).
•
After assembly, check all connections for leaks.