Caution: GAS PIPING TO YOUR GRILL MUST BE IN ACCORDANCE WITH LOCAL
CODES. IN ABSENCE OF LOCAL CODES, USE THE NATIONAL FUEL CODE ANSI
Z223.1/NFPT 54 (LATEST EDITION) or CAN/CGA B
-
149.1, NATURAL GAS AND
PROPANE INSTALLATION CODE.
Important: For connections to natural gas or remote self
-
contained LP gas supply sys-
tems (Bulk Tanks), use a qualified technician to install the gas line.
Notice to Installer
1.
Natural Gas Installation: The regulator on this grill was installed at the factory prior
to shipping. If it needs to be replaced, use only a TEC specified regulator that has
been pre
-
adjusted to the required gas pressure of the grill. LP Bulk Tank Installation:
The regulator/hose assembly included with TEC LP gas grills cannot be used with a
Bulk Tank. A TEC specified regulator must be purchased separately and attached to
the grill and used in conjunction with the regulator that is installed on the Bulk Tank.
2.
To ensure satisfactory performance, the gas supply line must be sized to accommo-
date the total BTU/HR requirements of all the gas fired equipment that will be con-
nected to the line. In no case should pipe or tubing be less than 1/2 inch (inside) di-
ameter.
3.
For Built
-
In installations, use rigid metal pipe or semi
-
rigid metal tubing to run your
gas supply line. Important: Do Not Use a Rubber Hose Within a Built
-
In Grill Enclo-
sure. For cart installations, use a flexible hose that will allow for movement in the
event that the cart shifts. Attach an approved flex connector to the piping hose that
complies with the Standard for Connectors for Outdoor Gas Appliances and Manu-
factured Homes, ANSI Z21.75.CSA 6.27
4.
Perform a gas leak test on the plumbing fittings after you have installed the gas line.
5.
The grill and shut
-
off valve must be disconnected from the gas supply piping system
during any pressure testing of the system at test pressures in excess of 1/2 PSIG
(13.5 in. w.c.).
6.
The grill must be isolated from the gas supply piping system by closing its individual
manual shut
-
off valve during any pressure testing of the system at test pressures
equal to or less than 1/2 PSIG (13.5 in. w.c.).
7.
Make sure that the owner knows where the gas supply shut
-
off valve is located be-
fore you leave.
8.
Leave this manual with the Owner and advise them to read it thoroughly and keep it
for future reference.