7
The mechanical thermostat should be set to the highest degree (90ºC) when the
stove is burning.The chain connected to the mechanical thermostat and the vent
cover ensures wide opening of the vent cover. After about 15-20 min – the stove
becomes hot enough - you can set the Mechanical Thermostat to the required
temperature, it should not be under 40ºC; otherwise it will not cause rapid
combustion.
4.2.2 Chimney Connection
For stove connection steel sheet flue pipes of 2mm thickness must be used. Stove
pipe must be connected to stove chimney output and chimney firmly. This strong
and close connection is also compulsory for flue pipes. After connecting flue pipe to
the chimney, remaining gaps around chimney must be closed with sealing and
fireproof materials. When the distance between stove and chimney is long,
horizontal connection must be avoided. Chimney pipe must be installed according
to the direction of the chimney. When the distance is short at least 1meter length
flue pipe must be used and must be installed vertically.
The chimney to be used at the exhaust gas outlet can be multiple chimney
connection (See Chimney Assembly Diagram)
CAUTION: Do not burn the stove when the flue pipe is connected. First of all,
the radiator installation must be done ( Otherwise stove burned without
water can lead to stove deformations). Our company is not responsible for
damages caused by burning without water.
The chimney connection should be done according to DIN4705.
5. STOVE WORK PRINCIPLES
The stove should only be used by adults. Children should not be alone with the
stove. The stove should only be used in accordance with this manual.
5.1 SUITABLE FUEL
Stove is suitable for highly efficient fuels. Approved fuel for combustion is listed in
the attached information sheet.
CAUTION : Since wood is not a permanently combustible fuel, it is impossible
to heat overnight