Design and function
Remote control
42
299-020100-TWD01
18.03.2016
5.8
Remote control
The remote controls are operated on the 19-pole remote control connection socket (analogue).
5.8.1
TW-RT1 19POL
Functions
• Infinitely adjustable welding current (0% to 100%) depending on the preselected
main current on the welding machine.
5.8.2
Power-saving mode (Standby)
You can activate the power-saving mode by either pressing the push-button - See 5.9 chapter for a
prolonged time or by setting a parameter in the machine configuration menu (time-controlled power-
saving mode)- See 5.9 chapter.
When power-saving mode is activated, the machine displays show the horizontal digit in the
centre of the display only.
Pressing any operating element (e.g. tapping the torch trigger) deactivates power-saving mode and the
machine is ready for welding again.
5.9
Machine configuration menu
ENTER (Enter the menu)
• Switch off machine at the main switch.
• Hold down the "Welding process" button and simultaneously switch the machine on again.
Wait until the "Elt" menu item is shown and release the button.
NAVIGATION (navigating in the menu)
• Parameters are selected by pressing the "welding parameters" button.
• Set or change the parameters by turning the "welding parameter setting" rotary dial.
EXIT (Exit the menu)
• Select the "EIt" menu item.
• Press the "Welding parameters" button (settings will be applied, machine changes to the
ready-to-operate status).