9 FAULT FINDING (COUGAR-VIPER SPORT)
When the handcycle is functioning correctly, the red LED that is situated on the controller is lit continually.
In the case of an electronic malfunction, the controller comes programmed with diagnostic capabilities to
determine where the fault lies. The red LED will emit a series of blinks, count them and refer to the table
below for explanation and solutions.
The faults listed may not cover every possible failure. In the event of moisture or water entering the
controller, haphazard signals might appear. The controller has been designed to repel water as much as
possible, encapsulating circuit boards with silicone resins.
This manual simply cannot cover every detail that might occur during the lifetime of your handcycle.
Please contact your dealer if you have any questions regarding your handcycle.
Number of Blinks Explanation
Solution
2
Brake lever cut off in
contact
Check brake lever spring, brake levers shoul return
to position
3
Brake lever cut off in
contact
Check wiring connection, inspect for damage to
battery level gauge
4
Throttle not in position
Check if throttle spring is faulty
5
Throttle failure
Check throttle connections or replace
6
Low voltage
Recharge battery or check for lose battery
connection
7
Excessively high voltage
Measure battery voltage, contact your dealer
8
Sensor fault
Contact your dealer
9
Motor incompatibility
Contact your dealer
10
Overheate, thermastat
activated
Allow to cool, reboot system
11
Thermostat failure
Replace controller
12
Amps control/controller
failure
Replace controller
No Light
Power failure
Check battery fuse, power cables or replace
controller
Two 15A fuses (in parallel) can be found on the bottom face of the battery.