SECTION 8. 

SOLENOID VALVE AND CONTROLS  

TROUBLE SHOOTING  

 

8.1 No valve functions at all. 

 

Possible causes 

a)  No oil flowing to valve 
b)  No power to the electric circuits. 
c)  Current overload protection operating. 
d)  Low voltage supply to control box - on light flashes 
e)  Low voltage to solenoid coils. 

Solution 

a)  Check hydraulic oil level on tractor & make sure oil being supplied to valve chest. 
b)  Check whether the fuse has blown indicated by the illumination of the red LED on the fuse holder, 

replace fuse with new 7.5 Amp fuse.  If a current overload has occurred and the on LED is 
flashing, the overload protection device needs to be reset by switching the control box off and on. 

c)  If there is a short circuit present within the electric controls then the current overload device will 

operate.  It  will be necessary to trace the fault before the controls will operate again.    

d)  Check the voltage supply to the unit is greater than 11V, if voltage is lower than 11V, ON/OFF 

switch will fail to operate. 

e)  Check voltage at coils is greater than 75% of coil rating (i.e. greater than 9v for a 12v solenoid 

coil). 

 

8.2 Bed chain fails to operate in both directions.  All other valve functions operate normally. 

 

Possible causes 

a)  Bed chain mechanically jammed in machine or drive to bed chain failed. 
b)  Hydraulic Motor failed or seized. 
c)  Failure of the wiring to the circuit board, the connections to the potentiometer within the control 

box or poor connections in the connector between the control box and machine cable. 

d)  Pilot orifice blocked in manifold of solenoid slice controlling bed chain forward and reverse. 

Solution 

a)  Check Bed chain and drive mechanically intact and working correctly. 
b)  Attach hoses directly to motor and run directly from tractor to prove motor failure. 
c)  Check all wiring for mechanical damage.  Follow procedure in Section 9.3 to solve problem. 
d)  Remove solenoid manifold and clean. 

 

8.3 Bed chain speed control fails but floor chain keeps moving.  All other valve functions remain 
working. 

 

Possible causes 

 

Spool of the proportional flow control slice jammed open or held open by contamination. 

 

Solution 

a)  Eliminate electronic controls by removing the coil from the proportional slice, if bed chain stops 

then the problem is electrical not mechanical. 

b) 

Remove the spool and check for contamination (Section 9.2).  Remove contamination and check 
spool is free to move.  

 

 

8.4 One function suddenly fails in both directions of operation. 

 

Possible causes 

a)  Pilot orifice in manifold blocked. 
b)  Damage to circuit board 

Solution 

a)  Remove manifold and clean  (Section 9.5) 

b)  Check junction box circuit board for burnt out circuits caused by a short circuit. Replace if 

damaged. 

 

 

Содержание Tomahawk 808S

Страница 1: ...lectronic System Details Issue 11 08 Tomahawk 808S From Serial No 2000 Tomahawk 8080 From Serial No 3800 Tomahawk 9090 From Serial No 1600 Tomahawk 1005 From Serial No 1501 Tomahawk 1010 From Serial No 3501 Instruction Book Parts List ...

Страница 2: ...r HEALTH AND SAFETY AT WORK Our equipment is designed so as to conform with current Health Safety Regulations and therefore poses no significant hazard to health when properly used Nevertheless in the interests of all concerned it is essential that equipment of our manufacture is used in accordance with the instructions that are supplied or are available from our Technical Staff Legislation requir...

Страница 3: ...Valve Parts List 8 SECTION 4 Hydraulic Hoses Parts List 12 SECTION 5 Electronic Control Identification 14 SECTION 6 Control Box Functions 15 SECTION 7 Circuit Diagrams 16 SECTION 8 Solenoid Valve And Controls Trouble Shooting 18 SECTION 9 Solenoid Valve And Controls Repair And Adjustment 20 SECTION 10 Solenoid Valve And Controls Parts List 23 ...

Страница 4: ... mounting bolts unbolt the box and refit reversed then replace the lid making sure the seal is correctly positioned It should be remembered that structural members of the cab must not be drilled or welded and thus some modification of the mounting bracket may be required Place the electric control unit in the cab and slot into the control box mounting bracket Provided with the controls is a supply...

Страница 5: ...5 NOTES ...

Страница 6: ...and rebuild With reference to Section 3 2 remove the pressure relief valve by unscrewing the complete valve from the slice and inspect the seat for contamination clean and replace 2 3 Bed chain speed control stops working on full or part bed chain speed Possible causes Flow control spool jammed open by contamination Solution Remove the valve guard from the front of the machine Slip the rubber shie...

Страница 7: ... body making sure the O ring remains outside the slip ring Reassemble the cable back onto the spool and refit the cap at the bottom of the valve IMPORTANT To ensure correct and reliable operation OEM components including O rings must be fitted during any overhaul of the valve failure to do so may lead to repeated failures as specific high quality grade O rings are used to seal the valve Remove the...

Страница 8: ...81 1 1 1 Control adapter kit 1 2 5 6 1 Actuator standard HYD5065 3 4 4 Actuator TMC Flow control HYD5066 1 1 1 2 Cable 3 5 meters long HYD5076 HYD5185 4 5 5 3 Actuator RDB HYD5184 4 5 5 Bent Handle HYD5182 4 5 5 Plain nut M10 FAS2303 4 5 5 Standard knob HYD5176 HYD5166 3 4 4 Round knob HYD5165 HYD5165 1 1 1 Actuator boot HYD5183 4 5 5 4 Adapter kit valve end HYD5079 HYD5186 3 4 4 5 Rubber sleeve H...

Страница 9: ... FAS2652P 4 4 4 Locknut M10 FAS2333 FAS2333 4 4 4 12 Divertor valve HYD5085 HYD5085 1 Bolt M6 x 70 FAS9614P FAS9614P 2 Washer M6 FAS2342P FAS2342P 4 Locknut M6 FAS2331 FAS2331 2 13 Hand valve mounting SC3461 SC3461 1 Setscrew M10 x 20 FAS2652P FAS2652P 4 Lock nut M10 FAS2333 FAS2333 4 14 Cable actuator mount T8080 SC3064 SC3717 1 Cable actuator mount T8080S TC SC3209 SC3717 1 1 Stud M6 x 195 FAS91...

Страница 10: ...10 3 2 CABLE CONTROL VALVE PARTS SEALS ...

Страница 11: ...w Outlet Ref Description cover detent spring 4 position valve valve control cover O ring with internal diameter of 3 69 mm and a material diameter of 1 78mm is specified by 3 69 x 1 78 Anti extrusion ring with internal diameter of 7 29 mm and a material thickness of 1 40mm is specified by 7 29 x 1 40 1 O ring 3 69 x 1 78 2 2 2 2 3 2 O ring 12 42 x 1 78 3 3 3 3 1 3 3 O ring 15 60 x 1 78 1 4 O ring ...

Страница 12: ...12 SECTION 4 HYDRAULIC HOSES PARTS LIST ...

Страница 13: ...04 2 L Divertor valve HYD5085 HYD5085 HYD5085 1 x BSP M M unions HYD1114 4 x 3 8 BSP M M unions HYD1115 2 Bonded seal BSP HYD4204 6 M Seg ram hose inner HYD5085 HYD5085 HYD5085 1 N Seg ram hose outer HYD2048 HYD2048 HYD2048 1 P Divertor valve hose HYD2048 HYD2048 HYD2048 2 Q Valve to T piece HYD2064 HYD2064 2 1 4 BSP T piece M M M HYD1921 2 R Chop unit side hose HYD2065 HYD2065 2 1 4 BSP M F 90 El...

Страница 14: ... Junction Box Grey Cable Enters Side Small Domed Buttons Chute Symbols Only Figure 5 3 Previous Design Small Domed Buttons Grey Cable Enters Top Control Box Junction Box NOTE All current design control desks have a serial number on the base of the control desk which can be identified through the aperture of the steel mounting plate Please quote the serial number when entering into any corresponden...

Страница 15: ...either of the two directional buttons 6 3 OVERLOAD PROTECTION Along with the in line fuse 7 5 amp the electronic controls also have a built in overload short circuit protector When the fuse fails the red LED on the fuse holder will illuminate When the protection device activates due to an overload the control box will not operate and the LED will flash In order to reset the device the control box ...

Страница 16: ...16 SECTION 7 CIRCUIT DIAGRAMS 7 1 SMALL DOMED BUTTONS ...

Страница 17: ...17 AS FITTED TO VALVE WITH INDEPENDENT SPEED CONTROL SLICE ON OFF DL1115 OFF ON DL1115 7 2 LARGE RAISED FLAT BUTTONS AS FITTED TO VALVE WITH COMBINED SPEED CONTROL FORWARD SLICE ...

Страница 18: ...jammed in machine or drive to bed chain failed b Hydraulic Motor failed or seized c Failure of the wiring to the circuit board the connections to the potentiometer within the control box or poor connections in the connector between the control box and machine cable d Pilot orifice blocked in manifold of solenoid slice controlling bed chain forward and reverse Solution a Check Bed chain and drive m...

Страница 19: ...ass Valve in the flow control slice does not allow it to close resulting in the oil dumping to tank starving any oil flow to the motor h Dirt or contamination in the Pressure Relief Valve in the flow control slice does not allow it to close resulting in the oil dumping to tank starving any oil flow to the motor i Dirt or contamination in the Pressurising Valve in the outlet cap does not allow it t...

Страница 20: ...n the control box is varied from stop to full flow it should be possible to measure the following voltages on the connector in the middle of the junction box circuit board cable labelled 3 12v 4 5v 5 0v 6 variable 0 to 5v If only the variable voltage has failed then the potentiometer in the cab control box may have a faulty connection or has failed Check for good connections if none are apparent r...

Страница 21: ...d position The pressure shown on the gauge should be 120 bar The pressure setting should remain the same throughout the whole range of bed chain speed To adjust the bed chain pressure remove the cap item 21 Section 10 2 over the relief valve To increase the bed chain pressure setting turn the grub screw item 20 clockwise until the desired setting is achieved Replace the cap 9 8 Pressurising valve ...

Страница 22: ...ontrol panel by following the instructions below Neither the control box or junction box needs to be opened 1 With the control box off and with reference to figure 6 1 hold the bed chain forward raise knives and ON buttons together for 8 seconds until both LED s are ON Set up mode will now be shown by the ON LED and Bed Chain LED flashing alternately 2 Set bed chain speed control dial to 0 5 reduc...

Страница 23: ...23 SECTION 10 SOLENOID VALVE AND CONTROLS PARTS LIST 10 1 DOUBLE ACTING SLICE ...

Страница 24: ...24 10 2 PROPORTIONAL SOLENOID SLICE INDEPENDENT BED CONTROL 10 3 PROPORTIONAL SOLENOID CARTRIDGE 10 4 OUTLET END CAP 10 5 PRESSURISING VALVE ASSEMBLY ...

Страница 25: ... control valve seal kit HYD5317 1 1 1 10 7 SOLENOID VALVE PARTS COMBINED SPEED CONTROL FORWARD SLICE Ref Description Part No RH SC DC TC A Cover Bed control end HYD5406 1 1 1 1 B Relief valve assembly HYD5407 1 1 1 1 C Double acting slice spring return HYD5192 2 3 4 5 D Flow control slice HYD5404 1 1 1 1 E Bed reverse slice HYD5405 1 1 1 1 F Outlet Cover HYD5315 1 1 1 1 G Flow dividing slice HYD51...

Страница 26: ... SC HYD5401 3 Valve DC HYD5402 4 Valve TC HYD5403 Note Valve mounting plate and fasteners are as for solenoid valve with independent speed control Ref Description Part No RH Chute SC Chute TC DC 1 Electric Valve HYD5094 1 2 Electric Valve HYD5095 1 3 Electric Valve HYD5096 1 4 Valve mount bracket SC3539 1 1 1 Setscrew M8 x 16 FAS2625P 4 Washer M8 FAS2343P 4 ...

Страница 27: ...3516 SC3516 SC3516 18 10 Control box socket SC3515 SC3515 SC3515 1 M4 x 16 Pan Head FAS2430S 4 M4 Locknut FAS2329S 4 11 Support Bracket SC3538 SC3538 SC3538 1 M4 x 16 Pan Head FAS2430S 4 M4 Locknut FAS2329S 4 Junction Box Assembly SC3557 SC3556 SC3542 1 12 Crimp contacts SC3519 SC3519 SC3519 18 13 Cable socket SC3518 SC3518 SC3518 1 14 18 Core cable assy 4m SC3522 SC3522 SC3522 1 18 Core cable ass...

Страница 28: ...racket SC3538 SC3538 SC3538 1 M4 x 16 Pan Head FAS2430S 4 M4 Locknut FAS2329S 4 Junction Box Assembly SC3583 SC3582 SC3581 1 12 Crimp contacts SC3519 SC3519 SC3519 18 13 Cable socket SC3518 SC3518 SC3518 1 14 18 Core cable assy 4m SC3522 SC3522 SC3522 1 Standard 18 Core cable assy 5m SC3592 SC3592 SC3592 1 Optional 18 Core cable assy 7m SC3594 SC3594 SC3594 1 Optional 15 PCB Large Controls SC3575 ...

Отзывы: