14
Troubleshooting
If you experience any problems with this unit, please take the
time to look through this chart. You may be able to solve the
problem yourself before calling your dealer or technical support.
No power
e
Check the connection to the AC power source. Check and
make sure the AC source is not a switched outlet and that,
if it is, the switch is turned on. Make sure there is power to
the AC outlet by plugging in another item such as a lamp or
fan.
No sound from speakers.
e
Check the connection to the digital device, amplifier and
speakers.
e
If the volume bypass is off, adjust the output level using the
OUTPUT buttons.
The INPUT indicator blinks.
e
Turn on the digital device connected to the input terminal.
e
Check the connection to the digital device. Make sure the
source digital device and the input selection on the D-01 are
the same type.
The safety circuit of the power amplifier is activated.
High-frequency noise from speakers.
e
Set 80kLPF to ON.
Buzzing noise produced at regular intervals.
e
The connected unit may not be in word sync mode while
the D-01 is in word sync mode. Check the word sync
terminal for correct connection and the settings on the
connected unit.
Normally, if this problem occurs, the display reads “WRD
ERROR”, but this message does not appear when deviation
in sync is too small and out of the word error detection
threshold of the D-01.
The WORD indicator blinks.
The display shows “No Word!”
e
The word sync mode is selected, but there is no clock
source. Turn the word sync mode off (see page 9).
e
Invalid word clock is being received. Check cables,
connections, and settings of the clock generator.
The display shows “WRD ERROR!”
e
Invalid word sync signal is received. Check the setting of the
clock generator.
The display shows “WRD UNLCK!”
e
Cannot lock the word sync signal. If “Rb IN” is selected,
select “IN” using the WORD button.
If normal operation cannot be recovered, unplug the
power cord from the outlet and plug it in again. This
resets the internal micro-computer which can be disturbed
during electrical storms, power interruptions, et cetera.
ES-LINK
appears when the ES-LINK compatible Esoteric product is
connected.
No Word!
There is no clock source.
UNKNOWN
The unit connected via the IEEE1394 cable is unknown.
WRD ERROR!
Invalid word sync signal is received.
WRD UNLCK!
Cannot lock the word sync signal.
LOOP ERR!
IEEE1394 connection is looped.
<
Normally, “the sampling frequency of an incoming digital
signal” when a CD is played back or “DSD” when an Super
Audio CD is played back are shown on the left of the display.
At the right shows the output level.
<
No output level shows when VOLUME BYPASS is switched on.
<
When detecting a device that is connected with IEEE 1394
cable, the display shows its model name (such as P-01).
Messages on the Display