TASCAM MD-CD1 RS-232C Protocol Specification
11
TEAC
Corporation
AUTO CUE LEVEL PRESET
Sets the Auto Cue Level of the controlled device.
A return command is returned only if Sense [FF] is specified.
The Auto Cue Mode setting is made using the command "AUTO CUE SELECT [30]."
Command 20
Machine ID
0
Data 2
bytes
Data 1
Data 2
Description
Remarks
0 0
Preset
–24dB
0 1
Preset
–30dB
0 2
Preset
–36dB
0 3
Preset
–42dB
0 4
Preset
–48dB
0 5
Preset
–54dB
0 6
Preset
–60dB
0 7
Preset
–66dB
0 8
Preset
–72dB
F
F
Sense
Requests that the current preset level be returned.
・
If data other than the above is received, the CD-RW901 will transmit ILLEGAL [F2].
Return
AUTO CUE LEVEL RETURN [A0]
AUTO TRACK LEVEL PRESET
Sets the Auto Track Level of the controlled device.
A return command is returned only if Sense [FF] is specified.
The Auto Track Mode setting is made using the command "AUTO TRACK SELECT [31]."
Command 21
Machine ID
0
Data 2
bytes
Data 1
Data 2
Description
Remarks
0 0
Preset
–24dB
0 1
Preset
–30dB
0 2
Preset
–36dB
0 3
Preset
–42dB
0 4
Preset
–48dB
0 5
Preset
–54dB
0 6
Preset
–60dB
0 7
Preset
–66dB
0 8
Preset
–72dB
F
F
Sense
Requests that the current preset level be returned.
・
If data other than the above is returned, the CD-RW901 will transmit ILLEGAL [F2].
Return
AUTO TRACK LEVEL RETURN [A1]