Rev Z

Figure 2

5. Holding the wire in place, squeeze the tool 
handles together until the ratchet releases. Allow 
the tool handles to open FULLY.

6. Remove crimped terminal or splice from the tool.

7. If crimping a splice, position the uncrimped wire 
barrel in the crimping chamber. Make sure to seat 
the splice window indent on the locator assembly. 
Repeat Steps 3 through 6.

Damaged or worn terminals must not be used. 

Terminals may be removed from the wire, 

discarded, and replaced with new ones.

4. CRIMP INSPECTION

— Check that the crimp dot code on the color-coded 

insulation indicates the crimping chamber used. Refer 
to Figure 2.

— Check that the crimp is centered on the wire 

barrel. See Figure 4.

— Make sure that the wire insulation does not enter 

the wire barrel. See Figure 4.

— Check that the wire end is flush with or slightly 

beyond the end of the wire barrel. See Figure 4.