TE 4020 Скачать руководство пользователя страница 3

MODEL 4020 & 4030 ACCELEROMETER 

 

TE CONNECTIVITY SENSORS

/// MODEL 4020 & 4030 ACCELEROMETER                05/2016

 

Page 3 

2x ¼ or M6 mounting screws 
Torque to 18 lb-in (2.0 Nm) 
 

DESCRIPTION 

The Model 4020 & 4030 are low noise, signal conditioned DC accelerometers packaged in a durable molded housing with an integral cable 
assembly. The accelerometers are offered in ±2g & ±6g ranges with a nominal 0-200Hz bandwidth and an operating temperature range of  -
40°C to +85°C. The model 4020 is a dual axis configuration while model 4030 is a triaxial configuration. 

 

INSTALLATION 

The  model  4020  &  4030  accelerometers  are  designed  to  be  screw  mounted.  The  following  guidelines  should  be  followed  when  screw 
mounting these accelerometers. 

 

The mounting surface should be clean and free of any residue or foreign material. 

 

The mounting surface should be smooth and flat. 

 

Torque screws to recommended limits using steel washers under the heads of the mounting screws. Use manual torque wrench (do  not 
use electric tools). 

 
 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

Содержание 4020

Страница 1: ...TE CONNECTIVITY SENSORS MODEL 4020 4030 ACCELEROMETER 05 2016 Page 1 OPERATION MANUAL MODEL 4020 4030 ACCELEROMETER ...

Страница 2: ...e unit is damaged in any way or fails to operate a claim should immediately be filed with the transportation company SERVICE CONCERNS If a Measurement Specialties Inc instrument requires service first contact the nearest Measurement Specialties Inc representative They may be able to solve the problem without returning the unit to the factory If it is determined that factory service is required cal...

Страница 3: ...h and an operating temperature range of 40 C to 85 C The model 4020 is a dual axis configuration while model 4030 is a triaxial configuration INSTALLATION The model 4020 4030 accelerometers are designed to be screw mounted The following guidelines should be followed when screw mounting these accelerometers The mounting surface should be clean and free of any residue or foreign material The mountin...

Страница 4: ...sed in single ended mode The sensor and electronics are fully contained in an internal Faraday cage which is connected to the cable shield floating with respect to circuit ground for RFI protection A 2 5Vdc bias will be present on the output leads and the output of the accelerometer will be 0 5 4 5V full scale The accelerometer should be connected to the interface circuitry as detailed below Biaxi...

Страница 5: ...ST OPERATION The model 4020 4030 accelerometers incorporate a self test feature This feature is activated by grounding the self test lead gray The corresponding shift in bias output is shown in table below Range g 2 6 Self Test Output Change mV X 210 90 X 70 30 Y 210 90 Y 70 30 Z 340 190 Z 110 65 The self test bias shift takes place no matter the orientation of the accelerometer Sensitivity is una...

Страница 6: ...indirect or consequential damages arising out of the sale resale use or misuse of the product Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application 2016 TE Connectivity Ltd family of companies All Rights Reserved FREQUENCY RESPONSE CURVES The typical frequency response curves for the model 4030 acceleromete...

Отзывы: