TE 4020 Скачать руководство пользователя страница 2

MODEL 4020 & 4030 ACCELEROMETER 

 

TE CONNECTIVITY SENSORS

/// MODEL 4020 & 4030 ACCELEROMETER                05/2016

 

Page 2 

WARRANTY 

Measurement Specialties, Inc. accelerometers are warranted during a period of one year from date of shipment to original purchaser to be free 
from  defects  in  material  and  workmanship.  The  liability  of  Seller  under  this  warranty  is  limited  to  replacing  or  repairing  any  instrument  or 
component  thereof  which  is  returned  by  Buyer,  at  his  expense,  during  such  period  and  which  has  not  been  subjected  to  misuse,  neglect, 
improper installation, repair, alteration, or accident. Seller shall have the right to final determination as to the existence and cause of a defect. 
In no event shall Seller be liable for collateral or consequential damages. This warrant is in lieu of any other warranty, expressed, implied, or 
statutory; and no agreement extending or modifying it will be binding upon Seller unless in writing and signed by a duly authorized officer. 
 

RECEIVING INSPECTION 

Every  Measurement  Specialties, Inc.  accelerometer is  carefully  inspected  and is  in  perfect  working  condition  at the  time  of shipment.  Each 
accelerometer should be checked as soon as it is received. If the unit is damaged in any way, or fails to operate, a claim should immediately 
be filed with the transportation company. 

 

SERVICE CONCERNS 

If  a  Measurement Specialties,  Inc.  instrument  requires service, first  contact the  nearest  Measurement Specialties,  Inc.  representative. They 
may  be  able to solve  the  problem  without  returning the  unit to the  factory. If  it  is  determined  that factory service  is  required,  call  Customer 
Service at the regional headquarters for an RMA number before return. 
 

RETURNS 

All units being returned to the factory require an RMA (Return Material Authorization) number before they will be accepted. This number may  
be  obtained  by  calling  Customer  Service  at  the  regional  headquarters  with  the  following  information;  model  number(s),  quantity,  serial 
number(s),  and  symptoms  of  the  problem,  if  being  returned  for  service.  You  must  include  the  original  purchase  order  number  if  under 
warranty. 
 

RECALIBRATION SERVICES 

The  Vibration  Sensors  Design  Center  and  its  two  manufacturing  facilities  in  China  and  France  offer  factory  re-calibration  services  for 
Piezoresistive,  Piezoelectric  and  Integrated  Electronics  Piezoelectric  (IEPE,  ISOTRON,  ICP,  etc.)  accelerometers.  NIST  (US),  DKD 
(Germany), COFRAC (France) traceable calibration services on sensitivity at 100 Hz (102 or 120 Hz in Europe) and full frequency sweeps are 
offered. Contact the regional headquarters for pricing information. 
 

 

 

Содержание 4020

Страница 1: ...TE CONNECTIVITY SENSORS MODEL 4020 4030 ACCELEROMETER 05 2016 Page 1 OPERATION MANUAL MODEL 4020 4030 ACCELEROMETER ...

Страница 2: ...e unit is damaged in any way or fails to operate a claim should immediately be filed with the transportation company SERVICE CONCERNS If a Measurement Specialties Inc instrument requires service first contact the nearest Measurement Specialties Inc representative They may be able to solve the problem without returning the unit to the factory If it is determined that factory service is required cal...

Страница 3: ...h and an operating temperature range of 40 C to 85 C The model 4020 is a dual axis configuration while model 4030 is a triaxial configuration INSTALLATION The model 4020 4030 accelerometers are designed to be screw mounted The following guidelines should be followed when screw mounting these accelerometers The mounting surface should be clean and free of any residue or foreign material The mountin...

Страница 4: ...sed in single ended mode The sensor and electronics are fully contained in an internal Faraday cage which is connected to the cable shield floating with respect to circuit ground for RFI protection A 2 5Vdc bias will be present on the output leads and the output of the accelerometer will be 0 5 4 5V full scale The accelerometer should be connected to the interface circuitry as detailed below Biaxi...

Страница 5: ...ST OPERATION The model 4020 4030 accelerometers incorporate a self test feature This feature is activated by grounding the self test lead gray The corresponding shift in bias output is shown in table below Range g 2 6 Self Test Output Change mV X 210 90 X 70 30 Y 210 90 Y 70 30 Z 340 190 Z 110 65 The self test bias shift takes place no matter the orientation of the accelerometer Sensitivity is una...

Страница 6: ...indirect or consequential damages arising out of the sale resale use or misuse of the product Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application 2016 TE Connectivity Ltd family of companies All Rights Reserved FREQUENCY RESPONSE CURVES The typical frequency response curves for the model 4030 acceleromete...