background image

409-10095 

Rev

 H

 

11 

of 12 

7.1.

 

Daily Maintenance 

Perform the following maintenance on a daily basis: 

1.  Inspect the dies for wear or damage such as cracks, gouges, or chips. 

2.  Inspect the tool for damage or leaks. If damage is detected, return the tool to TE for repair. 

3.  Clean the tool, removing accumulations of dirt and grease on the head, particularly in areas where 

dies are installed and terminals are crimped. Wipe the entire tool frequently with a clean, lint-free 
cloth. 

4.  Inspect the hydraulic hose and protective braided cover for signs of damage. If either appears loose, 

worn, cut, cracked, kinked, indented, pinched, pierced, burnt, partially dissolved, leaking or any other 
signs of damage are found DO NOT USE the tool. Serious injury to the user from oil injection may 
result. Remove the battery and return the unit to TE for service. 

NOTE 

BE SURE to return the tool to TE prior to the date indicated on the hose assembly for compulsory replacement of the hydraulic 

hose per CE requirements. Refer to the information provided in Section 9 to arrange the return of the tool. 

5.  Inspect the battery for signs of damage. If found damaged or leaking DO NOT USE. Properly dispose 

of the battery. If liquid from the battery comes in contact with a user, flush with water and seek medical 
attention as appropriate. 

6.  If the optional AC power adapter is used, inspect the adapter power cord. If damaged, replace the 

adapter. 

7.2.

 

Yearly Maintenance 

Once a year, or every 10,000 cycles (whichever comes first) The Electro-Hydraulic Hand Tool should be 
returned to TE for inspection. Refer to Section 8 for the return address. 

7.3.

 

General Notes 

NOTE 

The tool is factory calibrated for the output force. 

 

NOTE 

The tool is NOT intended to be field serviceable. Return the tool to TE for service. 

 

NOTE 

The tool contains a •voltage cut-off." That is, the tool will not slow down like similar battery powered tools when the battery 

charge gets low. Instead, when the battery reaches a pre-determined threshold value, the tool will shut down, indicating the 

battery needs to be charged. 

8.

 

RETURN/REPAIR 

Order replacement parts through your TE Representative, or call 1.800.522.6752; or write to: 

CUSTOMER SERVICE (38-35)  
TYCO ELECTRONICS CORPORATION 
PO BOX 3608 
HARRISBURG PA 17105-3608 

For a list of recommended spares, refer to Figure 5. 

TE PART NUMBER 

DESCRIPTION 

2031495-1 

Reset Tool 

2031440-1 

Rechargeable Battery 

Figure 5 

Содержание 2031400-1

Страница 1: ...5 Rev H SAFETY PRECAUTIONS READ THIS FIRST 2 SAFETY PRECAUTIONS AVOID INJURY READ THIS FIRST 3 1 INTRODUCTION 6 2 SPECIFICATIONS 7 3 RECEIVING INSPECTION 7 4 INSTALLATION REMOVAL OF CRIMP TOOLING 8 4...

Страница 2: ...nearby personnel Failure to observe this warning could result in severe injury or death CAUTION Do not place the tool in a vise The crimping tool is designed for hand held operation Protect the crimp...

Страница 3: ...tch and disconnect the electrical cord from the power source when performing repair or maintenance on the equipment Ensure that guards are in place and secure to equipment Do not operate the equipment...

Страница 4: ...calling the Support Center regarding service to equipment it is suggested that a person familiar with the device be present with a copy of the manual and drawings to receive instructions Many difficu...

Страница 5: ...17 EU 1 2031400 1 1 2031400 5 2063870 4 2063874 4 110 VAC JIS C 8303 JAPAN 3 2031400 1 3 2031400 5 2063870 3 2063874 3 220 VAC BS 1363 UK 4 2031400 1 4 2031400 5 2063870 5 2063874 5 220 VAC AS NZS 31...

Страница 6: ...d die sets are not included in this kit and must be ordered separately NOTE The tool should ONLY be used by trained competent operators This manual contains NOTE CAUTION and DANGER and WARNING stateme...

Страница 7: ...1 Li ion Battery Included in Kit 2031440 1 2031440 1 Bench Mount Assembly 2031403 1 2031403 1 Carrying Case with Shoulder Strap Included in Kit 2031489 1 2031489 1 Depends on the specific crimp toolin...

Страница 8: ...the crimping heads The installation and removal procedures for the adapters are identical to the installation removal procedures for the crimping heads 4 2 Installation Removal of Crimping Head Instal...

Страница 9: ...t opposite the hose toward the side of the power unit with the hose When the battery or AC adapter is fully installed there will be an audible click of the battery retention feature Removal To remove...

Страница 10: ...allow the crimp tool to cool for 15 minutes 6 PRESSURE RELEASE RESET TOOL The hydraulic pressure is released when a crimp is completed Alternately the power unit has a red pressure release button see...

Страница 11: ...y for signs of damage If found damaged or leaking DO NOT USE Properly dispose of the battery If liquid from the battery comes in contact with a user flush with water and seek medical attention as appr...

Страница 12: ...w oil or air in the oil Activate the pressure release button and hold the tool such that the TE label is vertical with the hose at the top Run the tool for one minute Reset the pressure release button...

Отзывы: